期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
眼动交互关键技术研究现状与展望 被引量:2
1
作者 杨晓楠 王帅 +2 位作者 牛红伟 薛庆 郝佳 《计算机集成制造系统》 EI CSCD 北大核心 2024年第5期1595-1609,共15页
随着计算机性能的不断提升,传统键鼠类窄带宽输入形式严重限制了计算机系统的工作效率。为了顺应高效、自然的人机交互发展趋势,眼动交互技术成为近年来的研究热点并取得了一定进展。在对眼动交互技术相关文献进行梳理的基础上,总结了... 随着计算机性能的不断提升,传统键鼠类窄带宽输入形式严重限制了计算机系统的工作效率。为了顺应高效、自然的人机交互发展趋势,眼动交互技术成为近年来的研究热点并取得了一定进展。在对眼动交互技术相关文献进行梳理的基础上,总结了眼动交互数据的一般处理与分析方法;围绕眼动交互过程存在的低空间精确度、米达斯接触以及视疲劳等关键问题展开描述,并对其解决方案进行了重点分析;最后,对眼动交互技术的前沿方向及发展趋势进行了展望,以期为后续相关研究提供有价值的参考。 展开更多
关键词 眼动交互 空间精确度 米达斯接触 视疲劳 意图识别
下载PDF
The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty 被引量:5
2
作者 吴立东 HAHNEH.J. HASSENPFLUGJ. 《Journal of Zhejiang University Science》 CSCD 2004年第10期1270-1278,共9页
Objective: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conve... Objective: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conventional group. Methods: Ten femoral components were implanted either manually or by CASPAR in cadaver femurs. The specimens were cut to 3mm thick slices. Microradiograms of every slice were sent to a computer for analysis with special software (IDL). The gaps and the medullary cavities between component and bone, the direct bone contact area of the implant surface, the gap width and the percentage of gap and bone contact area were measured in every slice. Results: In the proximal implant coated with HA of the CASPAR group, the average percentage of bone contact reached 93.2% (ranging from 87.6% to 99.7%); the average gap percentage was 2.9% (ranging from 0.3% to 7.8%); the maximum gap width was 0.81mm and the average gap width was only 0.20mm. While in the conventional group, the average percentage of bone contact reached 60.1% (ranging from 49.2% to 70.4%); the average gap percentage was 32.8% (ranging from 25.1% to 39.9%); the maximum gap width was 2.97mm and the average gap width was 0.77mm. The average gap around the implant in the CASPAR group was only 9% of that in the manual group; the maximum and average gap widths were only about 26% of those in the manual group. On the other hand, the CASPAR group showed 33% higher bone contact than the manual group. Conclusion: With the use of robotics-assisted system, significant progress can be achieved for femoral preparation in total hip arthroplasty. 展开更多
关键词 Total hip arthroplasty Femoral cavity preparation Robotics-assisted surgery
下载PDF
伽玛刀治疗磁共振影像定位精度的影响因素 被引量:5
3
作者 张宜培 张雪宁 +2 位作者 刘东 李彦和 徐德生 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2012年第4期383-385,共3页
目的通过对伽玛刀MRI定位像空间位置误差的研究,提高MRI定位像的几何精确度。方法将临床常用的NRI4种定位扫描序列输入伽玛刀治疗计划系统,测量各栅格节点坐标,比较各点坐标测量值与实际位置的误差,并分析坐标误差的空间分布。结果... 目的通过对伽玛刀MRI定位像空间位置误差的研究,提高MRI定位像的几何精确度。方法将临床常用的NRI4种定位扫描序列输入伽玛刀治疗计划系统,测量各栅格节点坐标,比较各点坐标测量值与实际位置的误差,并分析坐标误差的空间分布。结果各序列定位影像的栅格节点空间位置坐标误差均小于1mm。平均误差值以3DFSPGR和sET1加权序列较小。比较4种不同序列像坐标的平均误差值,在横轴位各序列的差异具有统计学意义(F=1497.51、1873.63、2.87、3.00,P〈0.05),冠状位各序列的差别无统计学意义。随着节点距中心点距离的增大,误差值有增大的趋势。结论磁共振成像的空间位置误差与成像序列参数直接相关,在定位时应根据患者病灶的影像学特点及位置合理选择成像序列参数,以减小定位MRI的空间位置误差。 展开更多
关键词 伽玛刀 放射外科 磁共振影像 空间精确度 误差
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部