期刊文献+
共找到80篇文章
< 1 2 4 >
每页显示 20 50 100
Characteristics of High-power GaAs Laser Beams and Their Coupling with Fibers 被引量:1
1
作者 YU Henry Hai-ying CUI Bi-feng TIAN Zeng-xia LIU Ying ZOU De-shu SHEN Guang-di 《Semiconductor Photonics and Technology》 CAS 2005年第4期233-238,共6页
The beams of 980nm high-power LDs are analyzed, and the reasons that aspect ratio of LD beams is high are explained. It is certified by the test that cylindrical lens can efficiently compress the perpendicular diverge... The beams of 980nm high-power LDs are analyzed, and the reasons that aspect ratio of LD beams is high are explained. It is certified by the test that cylindrical lens can efficiently compress the perpendicular divergence angle of the beam. Some typical and popular lensed fibers were compared and analyzed according to coupling characteristics. The factors which affect the coupling efficiency and tolerance of the wedged-shaped GRIN tipped lensed fiber are pointed out, and some methods to reduce the coupling loss of the lensed fibers are proposed finally. 展开更多
关键词 GaAs LD Lensed fibers Optical coupling mode GRIN fibers
下载PDF
飞秒激光屈光手术研究进展 被引量:14
2
作者 黄敬 周琼 《眼科新进展》 CAS 北大核心 2011年第8期793-796,800,共5页
飞秒激光以脉冲宽度短、瞬间功率高、重复频率高、单脉冲能量低、热效应小等特点应用于眼科屈光手术领域,成为屈光手术的未来新航向。其基本原理为光致破裂作用,在角膜组织中介导等离子切除,精细而稳定。本文就飞秒激光LASIK手术的参数... 飞秒激光以脉冲宽度短、瞬间功率高、重复频率高、单脉冲能量低、热效应小等特点应用于眼科屈光手术领域,成为屈光手术的未来新航向。其基本原理为光致破裂作用,在角膜组织中介导等离子切除,精细而稳定。本文就飞秒激光LASIK手术的参数选择、瓣质量评估、术后角膜创伤愈合与炎症反应以及最新术式FLEx/SMILE的新进展等进行综述。 展开更多
关键词 飞秒激光 准分子激光原位角膜磨镶术 飞秒激光透镜切除术 飞秒激光微小切口基质透镜切除术
下载PDF
飞秒激光角膜屈光手术的临床研究进展 被引量:2
3
作者 吴文静 王雁 《国际眼科纵览》 2013年第3期205-209,共5页
目前飞秒激光已广泛应用于激光角膜屈光手术中。激光角膜屈光手术根据飞秒激光的应用可分为两大类:飞秒激光辅助的准分子激光角膜原位磨镶术(FS—LASIK)以及全飞秒激光角膜屈光术,即屈光性透镜取出术(ReLEx)。ReLEx又可分为飞秒... 目前飞秒激光已广泛应用于激光角膜屈光手术中。激光角膜屈光手术根据飞秒激光的应用可分为两大类:飞秒激光辅助的准分子激光角膜原位磨镶术(FS—LASIK)以及全飞秒激光角膜屈光术,即屈光性透镜取出术(ReLEx)。ReLEx又可分为飞秒激光透镜取出术(ReLEx.flex,FLEx)和飞秒激光小切口透镜取出术(ReLEx—smile,SMILE)。本文回顾了FS—LASIK手术中瓣的侧切角、厚度、直径、形状等参数的设置,SMILE术中切口大小、位置,以及飞秒激光能量、点间距等参数的最新设置;并对三种手术的预测性、安全性、有效性,对角膜知觉的影响及其优点和不足进行综述。 展开更多
关键词 飞秒激光 屈光性透镜取出术 飞秒激光辅助的准分子激光角膜原位磨镶术 飞秒激光透镜取出术 飞秒激光小切口透镜取出术
原文传递
飞秒激光透镜切除术矫正近视的疗效分析
4
作者 曲怡茵 《中国实用医药》 2021年第31期62-64,共3页
目的 分析飞秒激光透镜切除术矫正近视的临床效果。方法 20例(40眼)近视患者,均接受飞秒激光透镜切除术治疗。比较术后不同时间(术后1 d、术后1周、术后1个月、术后3个月)视力水平及眼压情况。结果 患者术后1 d视力为(-0.03±0.01)... 目的 分析飞秒激光透镜切除术矫正近视的临床效果。方法 20例(40眼)近视患者,均接受飞秒激光透镜切除术治疗。比较术后不同时间(术后1 d、术后1周、术后1个月、术后3个月)视力水平及眼压情况。结果 患者术后1 d视力为(-0.03±0.01)、术后1周为(-0.08±0.05)、术后1个月为(-0.10±0.06)、术后3个月为(-0.15±0.08);患者术后1周、1个月、3个月视力水平与术后1 d比较,差异具有统计学意义(P<0.05)。术后1 d眼压为(16.14±2.37)mm Hg(1 mm Hg=0.133 kPa)、术后1周为(11.33±1.80) mm Hg、术后1个月为(11.50±2.75) mm Hg、术后3个月为(10.65±1.73) mm Hg;术后1周、1个月、3个月眼压均低于术后1 d,差异有统计学意义(P<0.05);术后1周眼压与术后1、3个月比较,差异无统计学意义(P>0.05)。结论 近视患者采用飞秒激光透镜切除术进行治疗,可快速达到治疗目的,能有效控制症状发展,临床疗效明显,且能一定程度上提高患者的生活质量,具有一定借鉴意义。 展开更多
关键词 飞秒激光透镜切除术 矫正近视 临床疗效
下载PDF
高度近视患者SMILE和FS-LASIK术后早期视觉质量的比较 被引量:14
5
作者 陈松林 郭露 +3 位作者 郐莉 孔祥梅 黄朝霞 吕红彬 《国际眼科杂志》 CAS 北大核心 2021年第5期890-894,共5页
目的:应用双通道视觉质量分析系统(OQASⅡ)及Pentacam角膜地形图对比研究高度近视患者分别行小切口飞秒激光角膜基质透镜取出术(SMILE)和飞秒激光辅助制瓣的准分子激光原位角膜磨镶术(FS-LASIK)后早期视觉质量的变化。方法:前瞻性非随... 目的:应用双通道视觉质量分析系统(OQASⅡ)及Pentacam角膜地形图对比研究高度近视患者分别行小切口飞秒激光角膜基质透镜取出术(SMILE)和飞秒激光辅助制瓣的准分子激光原位角膜磨镶术(FS-LASIK)后早期视觉质量的变化。方法:前瞻性非随机对照研究。选取2020-03/09于我院行手术矫治的高度近视患者74例148眼,其中SMILE组43例86眼,FS-LASIK组31例62眼。分析患者术前、术后1、7d裸眼视力(UCVA)、调制传递函数截止频率(MTF cut off)、斯特列尔比值(SR)、客观散射指数(OSI)、模拟对比度视力(VA 100%、VA 20%、VA 9%)、高阶像差(HOA)、水平彗差(Z_(3)^(1))、垂直彗差(Z_(3)^(-1))和球差(Z_(4)^(0))情况。结果:两组患者术前年龄、等效球镜、UCVA、MTF cut off、SR、OSI、VA 100%、VA 20%、VA 9%、HOA、Z_(3)^(1)、Z_(3)^(-1)和Z_(4)^(0)均无差异(P>0.05)。SMILE组术后1d OSI值高于FS-LASIK组(2.3±2.1 vs 1.8±1.1),术后7d无差异(1.2±0.7 vs1.3±0.7)。FS-LASIK组术后1、7d HOA和Z_(4)^(0)均高于SMILE组(P<0.001),但术后1、7d两组患者UCVA、Z_(3)^(1)、Z_(3)^(-1)、MTF cut off、SR、VA 100%、VA 20%、VA 9%均无差异(P>0.05)。结论:FS-LASIK术后早期更易引入角膜高阶像差和球差,而2mm切口的SMILE术仅在术后1d引入更高的散射,因此,高度近视患者行角膜屈光手术矫正采用SMILE术较FS-LASIK术后早期能够获得更佳的视觉质量。 展开更多
关键词 高度近视 角膜屈光手术 小切口飞秒激光角膜基质透镜取出术 飞秒激光辅助制瓣的准分子激光原位角膜磨镶术 视觉质量
下载PDF
FS⁃SBK术、SMILE术、LASIK术对近视及近视散光患者角膜生物力学、中央角膜内皮细胞的影响 被引量:12
6
作者 张醇 黎明 +3 位作者 应方微 贾惠莉 杨娟 王时娟 《实用医学杂志》 CAS 北大核心 2021年第14期1837-1841,1845,共6页
目的研究飞秒激光制瓣的SBK术(FS⁃SBK术)、小切口飞秒激光基质透镜取出术(SMILE术)、准分子激光原位角膜磨镶术(LASIK术)对近视及近视散光患者角膜生物力学、中央角膜内皮细胞的影响。方法选取2019年1-6月我院收治的近视散光患者150例,... 目的研究飞秒激光制瓣的SBK术(FS⁃SBK术)、小切口飞秒激光基质透镜取出术(SMILE术)、准分子激光原位角膜磨镶术(LASIK术)对近视及近视散光患者角膜生物力学、中央角膜内皮细胞的影响。方法选取2019年1-6月我院收治的近视散光患者150例,采用分层抽样法将患者分为FS⁃SBK术组、SMILE术组和LASIK术组各50例。FS⁃SBK术组使用FS⁃SBK术治疗,SMILE术组使用SMILE术治疗,LASIK术组使用LASIK术治疗,评价患者角膜生物力学指标、中央角膜内皮细胞指标ECD、CV、6A水平、角膜像差、视力、屈光度及并发症发生情况。结果SMILE术组患者角膜生物力学指标、中央角膜内皮细胞指标ECD、CV、6A水平、角膜像差、屈光度、并发症发生率低于FS⁃SBK术组和LASIK术组,视力高于FS⁃SBK术组和LASIK术组,差异有统计学意义(P<0.05)。FS⁃SBK术组和LASIK术组角膜生物力学指标、中央角膜内皮细胞指标ECD、CV、6A水平、角膜像差、视力、屈光度和并发症发生率比较,差异无统计学意义(P>0.05)。结论与FS⁃SBK术和LASIK术相比,SMILE术可显著改善角膜生物力学指标、中央角膜内皮细胞指标ECD、CV、6A水平、角膜像差、屈光度、并发症发生率,促进患者视力恢复。 展开更多
关键词 飞秒激光制瓣的SBK术 小切口飞秒激光基质透镜取出术 准分子激光原位角膜磨镶术 近视 近视散光
下载PDF
SMILE与FS-LASIK矫正近视和近视散光术后24小时内疗效比较 被引量:12
7
作者 石容 廖一露 +3 位作者 令狐绍容 但婷婷 李宗泽 刘太祥 《遵义医学院学报》 2019年第3期311-315,共5页
目的比较小切口飞秒激光角膜基质透镜取出术(Small incision lenticule extraction,SMILE)与飞秒激光辅助的 LASIK(Femtosecond laser-assisted laser in situ keratomileusis,FS-LASIK)矫正近视及近视散光术后24 h内疗效。方法行SMILE... 目的比较小切口飞秒激光角膜基质透镜取出术(Small incision lenticule extraction,SMILE)与飞秒激光辅助的 LASIK(Femtosecond laser-assisted laser in situ keratomileusis,FS-LASIK)矫正近视及近视散光术后24 h内疗效。方法行SMILE的近视患者18例(36眼),同期行FS-LASIK者15例(30眼),记录术前以及术后2、4、6、24 h的裸眼视力(Uncorrected visual acuity,UCVA)、等效球镜(Spherical equivalent,SE)、角膜光密度(Corneal densitometry,CD)、中央角膜厚度(Central corneal thickness,CCT)等。结果 SMILE组术后2 h 36眼中有17%≤0.1 logMAR UCVA,术后4、6、24 h 分别有22%、47%、92%≤0.1 logMAR UCVA;FS-LASIK组术后2 h 30眼中有10%≤0.1 logMAR UCVA,术后4、6、24 h 分别有30%、57%、90%≤0.1 logMAR UCVA。两组差异无统计学意义( P >0.05);两组术后24 h内屈光残留均在(±1.00D),两组比较术后各时间点SE无统计学差异( P >0.05)。两组术后平均角膜光密度均较术前显著增加( P <0.05),均在术后2h平均角膜光密度最大,术后4、6、24 h逐渐减小,两组比较无统计学意义( P >0.05);两组术后中央角膜厚度均随时间推移逐渐变薄,组内各时间点比较差异有统计学意义( P <0.05),组间比较无统计学差异( P >0.05)。结论 SMILE与FS-LASIK治疗近视和散光在术后最初24 h内视力和角膜状态均能快速恢复。该结果对于SMILE和FS-LASIK术后早期疗效的评估,尤其是对于具有迫切体检需求的患者,具有一定的参考意义。 展开更多
关键词 飞秒激光 小切口飞秒激光角膜基质透镜取出术 LASIK 近视 近视散光
下载PDF
2.0mm小切口飞秒激光角膜基质透镜取出术与飞秒激光辅助的LASIK矫正近视的疗效比较 被引量:12
8
作者 梅波 张卉卉 +5 位作者 段丽 朱涛 付竞 周维 赵春焕 易湘龙 《眼科新进展》 CAS 北大核心 2016年第12期1133-1137,共5页
目的比较2.0 mm微切口飞秒激光角膜基质透镜取出术(2.0 mm small incision lenticule extraction,2.0 mm SMILE)与飞秒激光辅助的LASIK(laser in situ keratomileusis with femtosecond laser,FS-LASIK)矫正近视的疗效。方法研究纳入行2... 目的比较2.0 mm微切口飞秒激光角膜基质透镜取出术(2.0 mm small incision lenticule extraction,2.0 mm SMILE)与飞秒激光辅助的LASIK(laser in situ keratomileusis with femtosecond laser,FS-LASIK)矫正近视的疗效。方法研究纳入行2.0 mm SMILE的近视患者48例(96眼),同期行FS-LASK者50例(100眼),记录并比较两组术前及术后1d、1周、1个月、3个月及6个月的裸眼视力(uncorrected visual acuity,UCVA)、最佳矫正视力(best corrected visual acuity,BCVA)、屈光度、生活质量量表(quality of life,QOL)得分及手术满意度量表评分。结果在术后1周以后SMILE组视力高于FS-LASIK组,且状态较FS-LASIK组更为稳定。术后1个月、3个月、6个月SMILE组UCVA≥术前BCVA的比例高于FS-LASIK组,差异均有统计学意义(均为P<0.05)。术后早期(术后1周)SMILE组存在1例过矫,而FS-LASIK组存在1例欠矫,但在术后1个月、3个月、6个月两组手术患者均在±1.00 D范围内。术后平均角膜前表面形态变异指数及垂直不对称指数在各时间点均为FS-LASIK组大于SMILE组,差异均有统计学意义(均为P<0.05)。两组术前及术后6个月QOL得分组间比较,差异均无统计学意义(均为P>0.05),术后6个月QOL得分均较术前有所增加,且差异均有统计学意义(SMILE:t=-13.85,P=0.00;FS-LASIK:t=-13.21,P=0.00),而两组术后6个月QOL得分比较,差异无统计学意义(P>0.05)。两组均有较高的再次手术选择率及手术推荐率,并且未发生严重的并发症。结论 2.0 mm SMILE与FS-LASIK均具有良好的有效性、稳定性以及可预测性,术后都可获得良好的视力及良好的生活质量,前者更好地保持了角膜前表面的形态。 展开更多
关键词 飞秒激光 2.0 mm小切口飞秒激光角膜基质透镜取出术 LASIK 近视
下载PDF
FS-LASIK与SMILE矫正近视术后角膜高阶像差的变化 被引量:11
9
作者 王嘉南 肖玥言 +3 位作者 郗平 高博 金玉梅 龙琴 《眼科新进展》 CAS 北大核心 2019年第6期540-543,共4页
目的比较飞秒激光制瓣准分子激光原位角膜磨镶术(femtosecond-assisted laser in situ keratomileusis,FS-LASIK)与小切口飞秒激光基质透镜切除术(small incision lenticule extraction,SMILE)术后角膜高阶像差的变化。方法选取行FS-LA... 目的比较飞秒激光制瓣准分子激光原位角膜磨镶术(femtosecond-assisted laser in situ keratomileusis,FS-LASIK)与小切口飞秒激光基质透镜切除术(small incision lenticule extraction,SMILE)术后角膜高阶像差的变化。方法选取行FS-LASIK患者22例(22眼)及行SMILE患者30例(30眼)作为研究对象,测量并对比2种术式患者术前及术后1周、1个月的角膜波前像差。结果 FS-LASIK术后1周球差、倾斜三叶草分别为(0.517±0.193)μm、(0.096±0.146)μm,与术前相比均增大,差异均有统计学意义(均为P<0.05)。FS-LASIK术后1个月球差、水平彗差、倾斜三叶草分别为(0.534±0.178)μm、(0.151±0.263)μm、(0.088±0.152)μm,与术前相比均增大,差异均有统计学意义(均为P<0.05)。SMILE术后1周球差、倾斜三叶草分别为(0.361±0.189)μm、(0.017±0.147)μm,与术前相比均增大,差异均有统计学意义(均为P<0.05)。SMILE术后1个月球差为(0.382±0.178)μm,与术前相比增大,差异有统计学意义(P<0.05)。术后1个月2组间球差、倾斜三叶草、总高阶像差均方根值差异均有统计学意义(t=3.043、2.647、2.391,均为P<0.05)。结论 FS-LASIK术后早期角膜高阶像差改变以球差、彗差、倾斜三叶草为主;SMILE术后早期角膜高阶像差改变以球差为主。FS-LASIK和SMILE术后早期球差、倾斜三叶草、总高阶像差有显著差异。 展开更多
关键词 近视 飞秒激光制瓣准分子激光原位角膜磨镶术 小切口飞秒激光基质透镜切除术 波前像差
下载PDF
催化激光热透镜光谱法测定铜 被引量:7
10
作者 阎宏涛 田欣 《分析化学》 SCIE EI CAS CSCD 北大核心 2000年第5期559-562,共4页
基于铜催化邻苯二胺氧化反应,以激光热透镜光谱法测定微量铜,讨论了测定条件的影响。结果表明,该方法测定灵敏度高,在0.2-1.2μg/L铜(Ⅱ)浓度范围内呈线性关系,重现性及回收率实验均取得满意的结果。
关键词 激光透镜光谱法 邻苯二胺 催化反应 测定
下载PDF
2-(3,5-二氯-2-吡啶偶氮)-5-二甲氨基苯胺激光热透镜光谱法测定钯 被引量:7
11
作者 张小玲 闫宏涛 刘根起 《分析化学》 SCIE EI CAS CSCD 北大核心 2002年第1期75-77,共3页
基于2-(3,5-二氯-2-吡啶偶氮)-5-二甲氨基苯胺(3,5-diCl-PADMA)与钯的显色反应,以激光热透镜光谱法测定了微量钯。实验表明:在强酸性介质中,Pd2+与3,5-diCl-PADMA室温显色形成稳定... 基于2-(3,5-二氯-2-吡啶偶氮)-5-二甲氨基苯胺(3,5-diCl-PADMA)与钯的显色反应,以激光热透镜光谱法测定了微量钯。实验表明:在强酸性介质中,Pd2+与3,5-diCl-PADMA室温显色形成稳定的蓝色配合物,最大吸收波长位于623 nm处,与所用激光器输出激光波长匹配较好,从而建立了激光热透镜光谱法测定钯的新方法。把浓度分别在0.005~0.04 mg/L和0.03-0.25mg/L范围内呈线性关系,方法灵敏度高,选择性、重现性好,用于样品测定,结果满意。 展开更多
关键词 激光透镜光谱法 2-(3 5-二氯-2-吡啶偶氮)-5-二甲氨基苯胺 显色剂 显色反应 测定 分析
下载PDF
SMILE和飞秒LASIK术后角膜神经修复的研究进展 被引量:6
12
作者 Jooyeon Son 周行涛 《交通医学》 2016年第2期125-128,共4页
飞秒激光小切口透镜取出术(small incision lenticule extraction,SMILE)和飞秒激光辅助的准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK),即飞秒LASIK是目前角膜屈光手术的两种常用手术方式,两种术式对角膜神经损伤和... 飞秒激光小切口透镜取出术(small incision lenticule extraction,SMILE)和飞秒激光辅助的准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK),即飞秒LASIK是目前角膜屈光手术的两种常用手术方式,两种术式对角膜神经损伤和修复的研究主要包括角膜知觉、干眼、角膜神经密度等变化。本文综合近期参考文献对SMILE和FS-LASIK治疗近视的特点、角膜神经的损伤和修复的临床和基础研究进行综述。 展开更多
关键词 飞秒激光小切口透镜取出术 飞秒激光辅助的准分子激光原位角膜磨镶术 近视 角膜神经
下载PDF
小切口全飞秒激光角膜基质透镜取出术病人的围术期护理 被引量:7
13
作者 吕云燕 《全科护理》 2016年第20期2115-2117,共3页
[目的]总结小切口全飞秒激光角膜基质透镜取出术围术期的护理。[方法]对36例(72眼)近视病人行小切口全飞秒激光角膜基质透镜取出术,做好围术期的护理及检查、复查的健康宣教工作。[结果]术后3个月达到或超过术前最佳矫正视力(72眼),其... [目的]总结小切口全飞秒激光角膜基质透镜取出术围术期的护理。[方法]对36例(72眼)近视病人行小切口全飞秒激光角膜基质透镜取出术,做好围术期的护理及检查、复查的健康宣教工作。[结果]术后3个月达到或超过术前最佳矫正视力(72眼),其中术后2例(2眼)发生角膜水肿,4周角膜水肿消退,病人对手术结果满意。[结论]全面细致的护理是SMILE术获得成功的关键。 展开更多
关键词 小切口全飞秒激光角膜基质透镜取出术 围术期 护理
下载PDF
光敏分离薄膜激光热透镜光谱法测定微区痕量汞的研究 被引量:6
14
作者 杨胜科 阎宏涛 《分析科学学报》 CAS CSCD 1995年第3期21-25,共5页
本文报道光敏分离薄膜激光热透镜光谱法测定微区痕量汞的研究。讨论了汞-双硫腙体系的光敏特性,及其光敏薄膜激光热这憾的产生机理,研究了不同溶剂介质对光敏分离薄膜热透镜信号的影响,采用光敏分离成功地进行了痕量汞的分离测定。... 本文报道光敏分离薄膜激光热透镜光谱法测定微区痕量汞的研究。讨论了汞-双硫腙体系的光敏特性,及其光敏薄膜激光热这憾的产生机理,研究了不同溶剂介质对光敏分离薄膜热透镜信号的影响,采用光敏分离成功地进行了痕量汞的分离测定。薄膜汞含量在50-400ng范围内,与其热透镜信号强度成正比。线性关系为Sc=0.0135C+0.2500,检测限为1×10-8g。对生物样品中痕量汞的测定获得满意结果。 展开更多
关键词 光敏分离 薄膜 激光透镜光谱
下载PDF
激光热透镜光谱分析法 被引量:6
15
作者 韩权 阎宏涛 《化学进展》 SCIE CAS CSCD 2002年第1期24-31,共8页
激光热透镜光谱法是 2 0世纪 80年代发展起来的一种光热光谱分析技术。该法以其高灵敏度、低检出限以及适应于微、少量样品分析等特点引起了分析工作者的极大兴趣。本文从测量装置、理论、痕量无机物和有机物测定以及与其它分析技术的... 激光热透镜光谱法是 2 0世纪 80年代发展起来的一种光热光谱分析技术。该法以其高灵敏度、低检出限以及适应于微、少量样品分析等特点引起了分析工作者的极大兴趣。本文从测量装置、理论、痕量无机物和有机物测定以及与其它分析技术的联用等方面对 1 990年以来激光热透镜光谱分析法的进展作了较为详细的综述。 展开更多
关键词 激光透镜光谱法 测量装置 应用 光谱分析 无机元素 痕量分析 有机分析 流动样品分析
下载PDF
SMILE和FS-LASIK术后干眼的对比研究 被引量:5
16
作者 孙熠 张文俊 曹虹 《国际眼科杂志》 CAS 2017年第1期50-53,共4页
目的:对比分析小切口飞秒激光基质透镜取出术(small incision lenticule extraction,SMILE)和飞秒激光准分子激光原位角膜磨镶术(femtosecond laser in situ keratomileusis,FS-LASIK)术后干眼及泪膜稳定性的变化。方法:回顾性分析2015-... 目的:对比分析小切口飞秒激光基质透镜取出术(small incision lenticule extraction,SMILE)和飞秒激光准分子激光原位角膜磨镶术(femtosecond laser in situ keratomileusis,FS-LASIK)术后干眼及泪膜稳定性的变化。方法:回顾性分析2015-01/06在我院行角膜屈光手术患者60例120眼。其中SMILE组30例60眼,FS-LASIK组30例60眼。观察两组患者术前、术后1wk,1、3、6mo的干眼症状、角膜荧光素染色(corneal fluorescein staining,FL)、基础泪液分泌试验(SchirmerⅠtest,SⅠt)、泪膜破裂时间(tear break-up time,BUT)的变化,并进行对比分析。结果:SMILE组和FS-LASIK组术后1wk、1mo干眼症状问卷评分分别为0.36±0.48、0.95±0.59分;0.15±0.36、0.36±0.60分,差异具有统计学意义(t=-5.8 8 5,P<0.0 1;t=-2.370,P=0.019)。SMILE组和FS-LASIK组术后1wk、1mo的FL评分分别为1.13±0.72、1.85±0.79分;0.68±0.50、1.38±0.55分,差异具有统计学意义(t=-5.149,P<0.01;t=-7.232,P<0.01)。SMILE组和FS-LASIK组术后1wk,1、3mo的SⅠt分别为13.11±1.93、8.76±1.36mm/5min,13.81±1.61、10.60±2.08mm/5min,14.45±1.51、11.85±2.42mm/5min,差异具有统计学意义(t=14.228,P<0.01;t=9.459,P<0.01;t=7.042,P<0.01)。SMILE组和FS-LASIK组术后1wk,1、3mo的BUT分别为11.15±1.71、8.55±1.19s;12.15±1.69、9.68±1.40s;12.51±1.83、10.93±1.90s,差异具有统计学意义(t=9.622,P<0.01;t=8.669,P<0.01;t=4.637,P<0.01)。结论:与FS-LASIK手术比较,SMILE手术切口小、术后干眼症状轻、恢复快,舒适度更高。 展开更多
关键词 小切口飞秒激光基质透镜取出术 飞秒激光准分子激光原位角膜磨镶术 干眼
下载PDF
催化近场激光热透镜光谱法测定痕量铱 被引量:6
17
作者 韩权 阎宏涛 《分析化学》 SCIE EI CAS CSCD 北大核心 2003年第5期608-610,共3页
将近场激光热透镜光谱分析法与动力学分析法相结合.基于铱(Ⅳ)催化高碘酸钾氧化耐尔蓝A的动力学反心,建立了催化近场激光热透镜光谱法测定痕量铱的新方法,并探讨了反应机理。结果表明:铱浓度在0.05~2.4μg/L范围内呈线性关系;俭出限为6... 将近场激光热透镜光谱分析法与动力学分析法相结合.基于铱(Ⅳ)催化高碘酸钾氧化耐尔蓝A的动力学反心,建立了催化近场激光热透镜光谱法测定痕量铱的新方法,并探讨了反应机理。结果表明:铱浓度在0.05~2.4μg/L范围内呈线性关系;俭出限为6.2 x 10-12g/mL。应用该方法测定矿样中痕量铱.结果满意。 展开更多
关键词 催化近场激光透镜光谱法 测定 痕量分析 耐尔蓝A 高碘酸钾 矿物
下载PDF
全飞秒激光角膜基质透镜切除术与飞秒激光制瓣的LASIK术后角膜地形图比较 被引量:5
18
作者 郑燕 周跃华 +3 位作者 张晶 刘倩 李颖 王明 《中华眼视光学与视觉科学杂志》 CAS 2014年第7期408-411,共4页
目的对全飞秒激光角膜基质透镜切除术(Flex)与飞秒激光制瓣的LASIK(FS—LASIK)术后3个月近视散光患者的角膜形态进行比较研究。方法前瞻性病例对照研究。对2013年1-9月在北京同仁医院的近视散光患者165例(323眼)进行Flex(87例17... 目的对全飞秒激光角膜基质透镜切除术(Flex)与飞秒激光制瓣的LASIK(FS—LASIK)术后3个月近视散光患者的角膜形态进行比较研究。方法前瞻性病例对照研究。对2013年1-9月在北京同仁医院的近视散光患者165例(323眼)进行Flex(87例170眼)或FS—LASIK(78例153眼)手术,术后3个月时,对2组视力、屈光状态及角膜形态参数进行独立样本t检验。结果Flex组和FS—LASIK组术后3个月时,logMARUCVA分别为-0.10±0.08和-0.11±0.10,矫正视力分别为-0.11±0.07和-0.12±0.07,均较术前BCVA(-0.07±0.03和-0.07±0.04)提高(t=4.083、5.594、3.458、6.440,P〈0.01),2种手术方式之间差异均无统计学意义(t=-0.811、-1.864,P〉O.05)。Flex和FS—LASIK切削偏心量分别为(0.29±0.17)mm和(0.40±0.17)mm,二者差异有统计学意义(t=5.662,P〈0.01)。Flex切削偏心程度与术前等效球镜度不相关(r=0.122,P〉0.05):FS—LASIK切削偏心程度与术前等效球镜度呈正相关(r=0.210,P〈0.01)。Flex和FS—LASIK术后角膜表面规则指数(SRI)分别为0.34±0.25和0.22±0.21,二者比较差异有统计学意义(t=-4.627,P〈0.01)。结论Flex术后切削偏心程度比FS-LASIK小,FS-LASIK术后角膜表面规则性比Flex更好,二者术后都可获得满意的视力。 展开更多
关键词 飞秒激光角膜基质透镜切除术 角膜磨镶术 激光原位 飞秒激光 角膜地形图 屈光手术
原文传递
角膜基质透镜散光标记器在角膜基质透镜植入术矫正远视及散光中的应用 被引量:4
19
作者 凌玲 陈敬旺 +2 位作者 姚玲 柯慧敏 周文天 《眼科新进展》 CAS 北大核心 2021年第9期861-864,共4页
目的探讨角膜基质透镜散光标记器(简称散光标记器)在角膜基质透镜植入术矫正远视及散光中的应用。方法前瞻性病例研究。选取2019年12月至2020年12月在南昌大学附属眼科医院屈光科就诊的满足手术要求的远视及散光患者6例6眼,年龄20~36(27... 目的探讨角膜基质透镜散光标记器(简称散光标记器)在角膜基质透镜植入术矫正远视及散光中的应用。方法前瞻性病例研究。选取2019年12月至2020年12月在南昌大学附属眼科医院屈光科就诊的满足手术要求的远视及散光患者6例6眼,年龄20~36(27.50±6.72)岁,所有患者均行飞秒激光辅助的瓣下角膜基质透镜植入术(FS-LIKE)。供体角膜取自同期行飞秒激光小切口角膜基质透镜取出术(SMILE)的近视患者,术中利用散光标记器标记角膜基质透镜散光轴位并植入到事先标记好轴位的植床以矫正远视和散光。术后随访6个月,观察所有术眼的裸眼视力(UCVA)、裸眼近视力(UNVA)、最佳矫正视力(BCVA)、等效球镜度、手术安全性及有效性。采用标准矢量分析法对手术前后散光相关指标进行评估。结果所有术眼术后1 d、1周、1个月、3个月、6个月UCVA、UNVA较术前均明显提高(F=5.503、2.968,P=0.002、0.031),术后不同时间点UCVA、UNVA两两比较差异均无统计学意义(均为P>0.05)。术后安全性指数及有效性指数分别为1.17±0.26、0.96±0.25。所有术眼术后BCVA较术前均未见丢失,4眼无变化,2眼提高2行。所有患者术后6个月手术矫正散光量及角度误差分别为(2.24±0.98)D、(5.33±5.79)°。结论散光标记器在FS-LIKE术中能有效标记散光轴位和受体角膜定位,能够有效安全地矫正患者术前远视及散光,为远视散光患者提供了新的、有效的一体式手术方式。 展开更多
关键词 角膜基质透镜散光标记器 飞秒激光辅助的瓣下角膜基质透镜植入术 小切口飞秒激光角膜基质透镜取出术 远视 散光
下载PDF
强化健康教育对小切口全飞秒激光角膜基质透镜取出术患者预后的影响 被引量:6
20
作者 易艳 谢雪儿 《齐齐哈尔医学院学报》 2019年第14期1831-1833,共3页
目的探讨强化健康教育对小切口全飞秒激光角膜基质透镜取出术(SMILE)患者预后的影响。方法收集2017年6月—2018年6月来本院进行SMILE手术的649例患者的临床资料,按照护理方案不同分为观察组(330例)和对照组(319例)两组。对照组患者接受... 目的探讨强化健康教育对小切口全飞秒激光角膜基质透镜取出术(SMILE)患者预后的影响。方法收集2017年6月—2018年6月来本院进行SMILE手术的649例患者的临床资料,按照护理方案不同分为观察组(330例)和对照组(319例)两组。对照组患者接受常规围术期护理,观察组患者在此基础上接受强化健康教育,比较两组患者干预前后心理状态评分变化、干预后健康知识知晓评分、术后依从情况、手术前后视力及屈光值变化情况。结果观察组患者干预后SAS及SDS评分均低于对照组,差异具有统计学意义(P<0.05);观察组患者干预后手术相关知识、术前训练知识、术后用药知识、自我护理知识、注意事项知晓评分均高于对照组,差异具有统计学意义(P<0.05);观察组患者术后用药、体位、行为、饮食、禁忌事项依从性均高于对照组,差异具有统计学意义(P<0.05);观察组患者术后3个月视力高于对照组,屈光值低于对照组,差异具有统计学意义(P<0.05)。结论强化健康教育能够改善小切口全飞秒激光角膜基质透镜取出术患者心理状态,提高健康知识知晓情况和术后依从性,提升手术效果。 展开更多
关键词 小切口全飞秒激光角膜基质透镜取出术 强化健康教育 心理状态 手术效果
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部