In order to improve aerodynamic performance and efficiency, monitoring the geometry and position information of the internal structure with the aero-engine under various operational statuses is an important task. In t...In order to improve aerodynamic performance and efficiency, monitoring the geometry and position information of the internal structure with the aero-engine under various operational statuses is an important task. In this paper, a novel design of industrial computed tomography(ICT) system with a linac as X-ray source is proposed to complete the task. The major advantage of the proposed system is that it can provide visualized images of internal structures of the running aero-engine without physical disturbance, which makes it possible to extract the accurate geometry information. The main idea behind this design is to measure the projection data from various views for reconstructions making use of the rotations of the aero-engine blades, instead of the mechanical rotations in the conventional ICT system. However, due to high speed rotation of the aero-engine blades,the system faces more challenges than conventional ICT systems both in data acquisitions and reconstruction algorithms. The challenges and corresponding solutions are presented in this paper. In conclusion, the proposed ICT system provides a powerful tool for monitoring the running aero-engines.展开更多
The recent increasing use of γ-rays industrial computed tomography(γ-rays ICT) in various fields has induced greater attention to its performance as well as to considerations of radiation safety. It is understood th...The recent increasing use of γ-rays industrial computed tomography(γ-rays ICT) in various fields has induced greater attention to its performance as well as to considerations of radiation safety. It is understood that radiation protection planning cannot be sacrificed for the sake of CT image quality during the design, manufacture,and layout of γ-rays ICT systems. In the present work, we describe a typical γ-rays ICT system in brief, and, based on experience and pertinent examples, we propose design requirements for ensuring the radiation safety of the sealed radioactive source, source container, and workspace. The design examples and dose rate measurement results illustrate that the proposed design standards are reasonable,feasible, and safe, and are therefore meaningful for the design, manufacture, and layout of γ-rays ICT systems. This paper discussed the predominant measures associated with the radiation protection of γ-rays ICT systems in accordance with the pertinent Chinese standards. In addition, based on experience and pertinent examples, the design requirements for ensuring the radiation safety of a sealed radioactive source, source container, and workspace were defined in detail. The design examples and dose rate measurements conducted in conjunction with a γ-rays ICT system and workspace employing the proposed design standards have illustrated that the proposals provided in this paper are reasonable, feasible, and safe, and are therefore meaningful for the design, manufacture, and layout of γ-rays ICT systems.展开更多
X-ray computer tomography(CT)has been intensively applied to the research of cement-based materials,while most of the CT applications are qualitative.To have more quantitative applications,the arbitrary grayscale valu...X-ray computer tomography(CT)has been intensively applied to the research of cement-based materials,while most of the CT applications are qualitative.To have more quantitative applications,the arbitrary grayscale values and the specially defined CT numbers of the main cement constituents,including the cement clinkers,the hydrated products,and some durability products are calibrated on an industrial CT system in this study.The calibration results can deepen our understandings of the X-ray CT image of the cement-based materials.The universalities of the calibrated results and the calibration procedures are clarified.The potential applications are anticipated,such as segmentation of the individual phases,quantitative durability research,porosity determinations,and quantitative composition characterizations.展开更多
基金Supported by the Transportation Construction Science and Technology Project(No.201332849A090)
文摘In order to improve aerodynamic performance and efficiency, monitoring the geometry and position information of the internal structure with the aero-engine under various operational statuses is an important task. In this paper, a novel design of industrial computed tomography(ICT) system with a linac as X-ray source is proposed to complete the task. The major advantage of the proposed system is that it can provide visualized images of internal structures of the running aero-engine without physical disturbance, which makes it possible to extract the accurate geometry information. The main idea behind this design is to measure the projection data from various views for reconstructions making use of the rotations of the aero-engine blades, instead of the mechanical rotations in the conventional ICT system. However, due to high speed rotation of the aero-engine blades,the system faces more challenges than conventional ICT systems both in data acquisitions and reconstruction algorithms. The challenges and corresponding solutions are presented in this paper. In conclusion, the proposed ICT system provides a powerful tool for monitoring the running aero-engines.
文摘The recent increasing use of γ-rays industrial computed tomography(γ-rays ICT) in various fields has induced greater attention to its performance as well as to considerations of radiation safety. It is understood that radiation protection planning cannot be sacrificed for the sake of CT image quality during the design, manufacture,and layout of γ-rays ICT systems. In the present work, we describe a typical γ-rays ICT system in brief, and, based on experience and pertinent examples, we propose design requirements for ensuring the radiation safety of the sealed radioactive source, source container, and workspace. The design examples and dose rate measurement results illustrate that the proposed design standards are reasonable,feasible, and safe, and are therefore meaningful for the design, manufacture, and layout of γ-rays ICT systems. This paper discussed the predominant measures associated with the radiation protection of γ-rays ICT systems in accordance with the pertinent Chinese standards. In addition, based on experience and pertinent examples, the design requirements for ensuring the radiation safety of a sealed radioactive source, source container, and workspace were defined in detail. The design examples and dose rate measurements conducted in conjunction with a γ-rays ICT system and workspace employing the proposed design standards have illustrated that the proposals provided in this paper are reasonable, feasible, and safe, and are therefore meaningful for the design, manufacture, and layout of γ-rays ICT systems.
基金supported by the Fundamental Research Funds for the Central Universities(Grant No.2242014R30014)State Key Laboratory of High Performance Civil Engineering Materials of China(Grant No.2012CEM008)
文摘X-ray computer tomography(CT)has been intensively applied to the research of cement-based materials,while most of the CT applications are qualitative.To have more quantitative applications,the arbitrary grayscale values and the specially defined CT numbers of the main cement constituents,including the cement clinkers,the hydrated products,and some durability products are calibrated on an industrial CT system in this study.The calibration results can deepen our understandings of the X-ray CT image of the cement-based materials.The universalities of the calibrated results and the calibration procedures are clarified.The potential applications are anticipated,such as segmentation of the individual phases,quantitative durability research,porosity determinations,and quantitative composition characterizations.