Cooling energy needs, for mines in Northern Ontario, are mainly driven by the mining cooling technologies available and the cost to implement them in a 2500 m deep underground mine. The cooling technologies reviewed h...Cooling energy needs, for mines in Northern Ontario, are mainly driven by the mining cooling technologies available and the cost to implement them in a 2500 m deep underground mine. The cooling technologies reviewed herein include mechanical and natural cooling systems, ranging from mechanical chillers to seasonal thermal storages. The economic and operating parameters for each technology were estimated and evaluated according to the mine's energy loads. Including consideration of any combined heat and power benefits of the technology, cooling tower requirements, etc., the resulting cost of implementation for each technology could be ranked. This showed that the natural thermal storage systems and conventional chillers were the most cost-effective, mainly since the natural systems had very low operating cost and the chillers had relatively low capital costs.展开更多
Cooling energy needs, for mines in Northern Ontario, are mainly driven by the mining depth and its operation. Part I of this research focusses on the thermal energy loads in deep mines as a result of the virgin rock t...Cooling energy needs, for mines in Northern Ontario, are mainly driven by the mining depth and its operation. Part I of this research focusses on the thermal energy loads in deep mines as a result of the virgin rock temperature, mining operations and climatic conditions. A breakdown of the various heat sources is outlined, for an underground mine producing 3500 tonnes per day of broken rock, taking into consideration the latent and sensible portions of that heat to properly assess the wet bulb global temperature. The resulting thermal loads indicate that cooling efforts would be needed both at surface and underground to maintain the temperature underground within the legal threshold. In winter the air might also have to be heated at surface and cooled underground, to ensure that icing does not occur in the inlet ventilation shaft-the main reason why coolin~ cannot be focussed solely at surface.展开更多
基金CEMI (Centre for Excellence in Mining Innovation) for their funding to support this research
文摘Cooling energy needs, for mines in Northern Ontario, are mainly driven by the mining cooling technologies available and the cost to implement them in a 2500 m deep underground mine. The cooling technologies reviewed herein include mechanical and natural cooling systems, ranging from mechanical chillers to seasonal thermal storages. The economic and operating parameters for each technology were estimated and evaluated according to the mine's energy loads. Including consideration of any combined heat and power benefits of the technology, cooling tower requirements, etc., the resulting cost of implementation for each technology could be ranked. This showed that the natural thermal storage systems and conventional chillers were the most cost-effective, mainly since the natural systems had very low operating cost and the chillers had relatively low capital costs.
基金CEMI (Centre for Excellence in Mining Innovation) for their funding to support this research
文摘Cooling energy needs, for mines in Northern Ontario, are mainly driven by the mining depth and its operation. Part I of this research focusses on the thermal energy loads in deep mines as a result of the virgin rock temperature, mining operations and climatic conditions. A breakdown of the various heat sources is outlined, for an underground mine producing 3500 tonnes per day of broken rock, taking into consideration the latent and sensible portions of that heat to properly assess the wet bulb global temperature. The resulting thermal loads indicate that cooling efforts would be needed both at surface and underground to maintain the temperature underground within the legal threshold. In winter the air might also have to be heated at surface and cooled underground, to ensure that icing does not occur in the inlet ventilation shaft-the main reason why coolin~ cannot be focussed solely at surface.