The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the or...The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the original interceptive fluorescent target. This paper gives out the theoretical analysis and bench test result of the strip line BPM. The BPM has a characteristic impedance of (50±5)?, a reflection coefficient of less than –4 dB, a band-width of 400 MHz, a coupling coefficient of less than -15 dB, and a sensitivity of 1.16 dB/mm. Additionally, the strip line BPM has a good linearity.展开更多
A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity er...A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.展开更多
基金Supported by Project of Building a High-level University Well-known Both in China and in the World (KY2901), and Project of Hi-tech Research and Development Program of China (863-410-8-2)
文摘The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the original interceptive fluorescent target. This paper gives out the theoretical analysis and bench test result of the strip line BPM. The BPM has a characteristic impedance of (50±5)?, a reflection coefficient of less than –4 dB, a band-width of 400 MHz, a coupling coefficient of less than -15 dB, and a sensitivity of 1.16 dB/mm. Additionally, the strip line BPM has a good linearity.
文摘A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.