It is necessary that the laser inertial system is used to further improve the fire accuracy and quick reaction capability in the ballistic missile strapdown inertial navigation system. According to the guidance contro...It is necessary that the laser inertial system is used to further improve the fire accuracy and quick reaction capability in the ballistic missile strapdown inertial navigation system. According to the guidance controlling method and the output and error model of ballistic missile laser SIMU, the mathematical model of error propagation mechanism is set up and any transfer environmental function of error coefficient that affects the fire accuracy is deduced. Also, the missile longitudinal/lateral impact point is calculated using MATLAB. These establish the technical foundation for further researching the dispersion characteristics of impact point and reducing the laser guidance error.展开更多
Standard mica was used to correct the X-ray powder diffraction instrument error and mathematic methods were employed to find the correction equation. By analyzing mullite sample and comparing the corrected and uncorre...Standard mica was used to correct the X-ray powder diffraction instrument error and mathematic methods were employed to find the correction equation. By analyzing mullite sample and comparing the corrected and uncorrected analysis results we found the former is obviously more reasonable. So the conclusion is that the X-ray powder diffraction instrument error greatly affects the crystalline structure analysis, and the above method is convenient and effective for the correction of instrument error.展开更多
文摘It is necessary that the laser inertial system is used to further improve the fire accuracy and quick reaction capability in the ballistic missile strapdown inertial navigation system. According to the guidance controlling method and the output and error model of ballistic missile laser SIMU, the mathematical model of error propagation mechanism is set up and any transfer environmental function of error coefficient that affects the fire accuracy is deduced. Also, the missile longitudinal/lateral impact point is calculated using MATLAB. These establish the technical foundation for further researching the dispersion characteristics of impact point and reducing the laser guidance error.
基金This work was financially supported by the Natural Science Foundation of Fujian Province (No. K03007)
文摘Standard mica was used to correct the X-ray powder diffraction instrument error and mathematic methods were employed to find the correction equation. By analyzing mullite sample and comparing the corrected and uncorrected analysis results we found the former is obviously more reasonable. So the conclusion is that the X-ray powder diffraction instrument error greatly affects the crystalline structure analysis, and the above method is convenient and effective for the correction of instrument error.