The slotted-orifice is a new type of flow sensor for gas-liquid two-phase flow measurement,and there is no correlation of two-phase multipliers for the slotted-orifice available.Based on the air-water two-phase flow e...The slotted-orifice is a new type of flow sensor for gas-liquid two-phase flow measurement,and there is no correlation of two-phase multipliers for the slotted-orifice available.Based on the air-water two-phase flow experimental data of slotted-orifice,five typical correlations of the standard throttle device were applied to the data,and the application range and the reason for error involved from these correlations were analyzed.Based on different modeling ideas,three new correlations,which include the Lockhart-Martinelli parameter,gas pressure and gas Froude number,were proposed and used in the study of metering technology of wet gas flow.The accuracy of new correlations can meet the gas industry demands for production based metering.展开更多
As international maritime organization (IMO) draft 289 was adopted to develop a low-alloy anti-corrosion steel for the deck of cargo oil tank and to understand corrosion mechanism, corrosion behavior of a low-alloy ...As international maritime organization (IMO) draft 289 was adopted to develop a low-alloy anti-corrosion steel for the deck of cargo oil tank and to understand corrosion mechanism, corrosion behavior of a low-alloy steel with chromium contents was studied in O2-CO2-SO2-H2 S wet gas environment. Corrosion rate was measured, and the microstructure and morphology of corrosion product film were characterized by scanning electron microscopy (SEM). The phase and chemical composition of the corrosion product film were investigated by X-ray diffraction (XRD) and energy dispersive spectroscopy (EDS), respectively. The effect of misorientation distribution on corro- sion resistance of steel was evaluated by electron backscattered diffraction (EBSD). The results showed that corro- sion rate decreased with increasing chromium content in the low-alloy steel, and the corrosion type was general corrosion. The phenomenon of chromium enrichment was found in corrosion product film consisting of a-FeOOH, γ- FeOOH, sulphur, FeS2 and Fel-xS. The increase of chromium content decreases the amount of high-angle grain boundaries, thus resulting in the improvement of corrosion resistance.展开更多
The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field...The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed. Three 50 mm Venturi meters were tested systematically, with fl values of 0.4048, 0.55 and 0.70, the opera- tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio, and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore, low-pressure performance was compared with that under high pressure.展开更多
文摘The slotted-orifice is a new type of flow sensor for gas-liquid two-phase flow measurement,and there is no correlation of two-phase multipliers for the slotted-orifice available.Based on the air-water two-phase flow experimental data of slotted-orifice,five typical correlations of the standard throttle device were applied to the data,and the application range and the reason for error involved from these correlations were analyzed.Based on different modeling ideas,three new correlations,which include the Lockhart-Martinelli parameter,gas pressure and gas Froude number,were proposed and used in the study of metering technology of wet gas flow.The accuracy of new correlations can meet the gas industry demands for production based metering.
基金Item Sponsored by National Science and Technology Major Project of the Ministry of Science and Technology of China(2011ZX05016-004)National Key Technology Research and Development Program of the Ministry of Science and Technology of China(2011BAE25B00)
文摘As international maritime organization (IMO) draft 289 was adopted to develop a low-alloy anti-corrosion steel for the deck of cargo oil tank and to understand corrosion mechanism, corrosion behavior of a low-alloy steel with chromium contents was studied in O2-CO2-SO2-H2 S wet gas environment. Corrosion rate was measured, and the microstructure and morphology of corrosion product film were characterized by scanning electron microscopy (SEM). The phase and chemical composition of the corrosion product film were investigated by X-ray diffraction (XRD) and energy dispersive spectroscopy (EDS), respectively. The effect of misorientation distribution on corro- sion resistance of steel was evaluated by electron backscattered diffraction (EBSD). The results showed that corro- sion rate decreased with increasing chromium content in the low-alloy steel, and the corrosion type was general corrosion. The phenomenon of chromium enrichment was found in corrosion product film consisting of a-FeOOH, γ- FeOOH, sulphur, FeS2 and Fel-xS. The increase of chromium content decreases the amount of high-angle grain boundaries, thus resulting in the improvement of corrosion resistance.
基金the National High Technology Research and Development Program of China(2006AA04Z167,2007AA04Z180)
文摘The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed. Three 50 mm Venturi meters were tested systematically, with fl values of 0.4048, 0.55 and 0.70, the opera- tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio, and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore, low-pressure performance was compared with that under high pressure.