The purpose of this paper is to investigate the performance improvement mechanism of a high power vertical centrifugal pump by using numerical calculations.Therefore,a comparative study of energy losses and internal f...The purpose of this paper is to investigate the performance improvement mechanism of a high power vertical centrifugal pump by using numerical calculations.Therefore,a comparative study of energy losses and internal flow characteristics in the original and optimized models was carried out with special attention to the hydraulic component matching.The optimized model(model B)was obtained by optimizing the vaned diffuser and volute based on the original model(model A),mainly the diffuser inlet diameter,diffuser inlet vane angle,volute channel inlet width and volute throat area were changed.Firstly,the comparative results on performance and energy losses of two models showed that the efficiency and head of model B was significantly increased under design and part-load conditions.It is mainly due to the dramatic reduction of energy loss PL in the diffuser and volute.Then,the comparisons of PL and flow patterns in the vaned diffuser showed that the matching optimization between the model B impeller outlet flow angle and diffuser inlet vane angle resulted in a better flow pattern in both the circumferential and axial directions of the diffuser,which leads to the PL3 reduction.The meridian velocity Vm of model B was significantly increased at diffuser inlet regions and resulted in improvements of flow patterns at diffuser middle and outlet regions as well as pressure expansion capacity.Finally,the comparisons of PL and flow characteristics in the volute showed that the turbulence loss reduction in the model B volute was due to the flow pattern improvement at diffuser outlet regions which provided better flow conditions at volute inlet regions.The matching optimization between the diffuser and volute significantly reduced the turbulence loss in volute sections 1–4 and enhanced the pressure expansion capacity in sections 8–10.展开更多
Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on th...Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials.展开更多
The flow structure around the intake of a vertical pump is investigated experimentally and numerically in order to obtain a guideline in designing the optimum shape of the intake of vertical pumps, in which their inst...The flow structure around the intake of a vertical pump is investigated experimentally and numerically in order to obtain a guideline in designing the optimum shape of the intake of vertical pumps, in which their installation area is demanded to be minimum without losing the high performance. We concentrate our attention on the expansion ratio of the intake as a representative characteristic of the shape of the pumps and investigate the effect of the expansion ratio on pump performance. It is concluded that the optimum expansion ratio ranges in 1.1-1.2 if we take into consideration that the area needed for the installation of the pump should be minimum.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.51979125)supported by the Jiangsu Provincial Science Fund for Distinguished Young Scholars(Grant No.BK20211547)+2 种基金the Technological Innovation Team Project in Colleges and Universities of Jiangsu Province(Grant No.SKJ(2021)-1)the Open Research Subject of Key Laboratory of Fluid Machinery and Engineering(Xihua University)of Sichuan Province(Grant No.LTDL-2022007)the Graduate Research and Innovation Projects of Jiangsu Province(Grant No.KYCX23_3701).
文摘The purpose of this paper is to investigate the performance improvement mechanism of a high power vertical centrifugal pump by using numerical calculations.Therefore,a comparative study of energy losses and internal flow characteristics in the original and optimized models was carried out with special attention to the hydraulic component matching.The optimized model(model B)was obtained by optimizing the vaned diffuser and volute based on the original model(model A),mainly the diffuser inlet diameter,diffuser inlet vane angle,volute channel inlet width and volute throat area were changed.Firstly,the comparative results on performance and energy losses of two models showed that the efficiency and head of model B was significantly increased under design and part-load conditions.It is mainly due to the dramatic reduction of energy loss PL in the diffuser and volute.Then,the comparisons of PL and flow patterns in the vaned diffuser showed that the matching optimization between the model B impeller outlet flow angle and diffuser inlet vane angle resulted in a better flow pattern in both the circumferential and axial directions of the diffuser,which leads to the PL3 reduction.The meridian velocity Vm of model B was significantly increased at diffuser inlet regions and resulted in improvements of flow patterns at diffuser middle and outlet regions as well as pressure expansion capacity.Finally,the comparisons of PL and flow characteristics in the volute showed that the turbulence loss reduction in the model B volute was due to the flow pattern improvement at diffuser outlet regions which provided better flow conditions at volute inlet regions.The matching optimization between the diffuser and volute significantly reduced the turbulence loss in volute sections 1–4 and enhanced the pressure expansion capacity in sections 8–10.
基金Project(CSTC 2004AA7008 2 2) supported by Key Technologies for Development of Small Cities of ChongqingMunicipality
文摘Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials.
文摘The flow structure around the intake of a vertical pump is investigated experimentally and numerically in order to obtain a guideline in designing the optimum shape of the intake of vertical pumps, in which their installation area is demanded to be minimum without losing the high performance. We concentrate our attention on the expansion ratio of the intake as a representative characteristic of the shape of the pumps and investigate the effect of the expansion ratio on pump performance. It is concluded that the optimum expansion ratio ranges in 1.1-1.2 if we take into consideration that the area needed for the installation of the pump should be minimum.