The Vienna rectifier with unbalanced input voltage and load transient is analyzed.A nonlinear control strategy for Vienna rectifier under unbalanced input is proposed.From the view of positive and negative sequence co...The Vienna rectifier with unbalanced input voltage and load transient is analyzed.A nonlinear control strategy for Vienna rectifier under unbalanced input is proposed.From the view of positive and negative sequence components,the proposed nonlinear control strategy suppresses the twice frequency ripple and guarantees the dynamic response characteristic at the same time.Thanks to the proposed nonlinear control strategy,the DC bus capacitor can be reduced a lot since the voltage ripple and drop can be suppressed.A 10 kW Vienna rectifier is built to verify the proposed control strategy.After applying the proposed nonlinear control strategy,the voltage ripple is only7 V and decreases over 75%over the traditional PI control when the unbalanced degree is 20%.The voltage drop can be reduced about 80%than former control strategy which is helpful to reduce the DC bus capacitor and achieve higher power density.The volume of the capacitor can be reduced by 83.3%with the new control method.展开更多
In this paper, a voltage oriented control strategy for three-level PWM rectifier based on Sliding Mode Control (SMC) is introduced in order to obtain fast and accurate response of dc-bus voltage. To verify the validit...In this paper, a voltage oriented control strategy for three-level PWM rectifier based on Sliding Mode Control (SMC) is introduced in order to obtain fast and accurate response of dc-bus voltage. To verify the validity of the analysis and the feasibility of the proposed control method a set of simulation tests have been conducted using Matlab/Simulink. The simulation results show that compared to the conventional PI controller, the SMC can reduce drastically the three-level rectifier’s voltage fluctuation and improve the dynamic response of dc-bus significantly.展开更多
Pre-and post-selected(PPS) measurement, especially the weak PPS measurement, has been proved to be a useful tool for measuring extremely tiny physical parameters. However, it is difficult to retain both the attainable...Pre-and post-selected(PPS) measurement, especially the weak PPS measurement, has been proved to be a useful tool for measuring extremely tiny physical parameters. However, it is difficult to retain both the attainable highest measurement sensitivity and precision with the increase of the parameter to be measured. Here, a modulated PPS measurement scheme based on coupling-strength-dependent modulation is presented with the highest sensitivity and precision retained for an arbitrary coupling strength. This idea is demonstrated by comparing the modulated PPS measurement scheme with the standard PPS measurement scheme in the case of unbalanced input meter. By using the Fisher information metric, we derive the optimal pre-and post-selected states, as well as the optimal coupling-strength-dependent modulation without any restriction on the coupling strength. We also give the specific strategy of performing the modulated PPS measurement scheme, which may promote practical application of this scheme in precision metrology.展开更多
基金supported in part by the National Natural Science Foundation of China (Nos. 51777093 ,51722702)
文摘The Vienna rectifier with unbalanced input voltage and load transient is analyzed.A nonlinear control strategy for Vienna rectifier under unbalanced input is proposed.From the view of positive and negative sequence components,the proposed nonlinear control strategy suppresses the twice frequency ripple and guarantees the dynamic response characteristic at the same time.Thanks to the proposed nonlinear control strategy,the DC bus capacitor can be reduced a lot since the voltage ripple and drop can be suppressed.A 10 kW Vienna rectifier is built to verify the proposed control strategy.After applying the proposed nonlinear control strategy,the voltage ripple is only7 V and decreases over 75%over the traditional PI control when the unbalanced degree is 20%.The voltage drop can be reduced about 80%than former control strategy which is helpful to reduce the DC bus capacitor and achieve higher power density.The volume of the capacitor can be reduced by 83.3%with the new control method.
文摘In this paper, a voltage oriented control strategy for three-level PWM rectifier based on Sliding Mode Control (SMC) is introduced in order to obtain fast and accurate response of dc-bus voltage. To verify the validity of the analysis and the feasibility of the proposed control method a set of simulation tests have been conducted using Matlab/Simulink. The simulation results show that compared to the conventional PI controller, the SMC can reduce drastically the three-level rectifier’s voltage fluctuation and improve the dynamic response of dc-bus significantly.
基金supported by the National Natural Science Foundation of China(Grant Nos.11674234 and 11605205)the Fundamental Research Funds for the Central Universities,China(Grant No.2012017yjsy143)+4 种基金the National Key Research and Development Program of China(Grant No.2017YFA0305200)the Youth Innovation Promotion Association of Chinese Academy of Sciences(CAS)(Grant No.2015317)the Natural Science Foundation of Chongqing,China(Grant Nos.cstc2015jcyjA00021 and cstc2018jcyjAX0656)the Entrepreneurship and Innovation Support Program for Chongqing Overseas Returnees,China(Grant No.cx017134)the Fund of CAS Key Laboratory of Microscale Magnetic Resonance,China,and the Fund of CAS Key Laboratory of Quantum Information,China
文摘Pre-and post-selected(PPS) measurement, especially the weak PPS measurement, has been proved to be a useful tool for measuring extremely tiny physical parameters. However, it is difficult to retain both the attainable highest measurement sensitivity and precision with the increase of the parameter to be measured. Here, a modulated PPS measurement scheme based on coupling-strength-dependent modulation is presented with the highest sensitivity and precision retained for an arbitrary coupling strength. This idea is demonstrated by comparing the modulated PPS measurement scheme with the standard PPS measurement scheme in the case of unbalanced input meter. By using the Fisher information metric, we derive the optimal pre-and post-selected states, as well as the optimal coupling-strength-dependent modulation without any restriction on the coupling strength. We also give the specific strategy of performing the modulated PPS measurement scheme, which may promote practical application of this scheme in precision metrology.