With more and more wind power generation integrated into power grids to replace the conventional turbine-generator (T-G) units,how the subsynchronous resonance (SSR) of conventional T-G units is affected becomes an im...With more and more wind power generation integrated into power grids to replace the conventional turbine-generator (T-G) units,how the subsynchronous resonance (SSR) of conventional T-G units is affected becomes an important technical issue.In this paper,a group of T-G units are interconnected with a series compensated transmission line,and some units are substituted by a nearby DFIG-based wind farm (WF).Under such circumstances,the SSR of power systems would change accordingly.This paper establishes the mathematical model to analyze the torsional interaction (TI) and the induction generator effect of the T-G units.Both eigenvalue analysis and time domain simulations demonstrate the impact of DFIG-based WF on SSR of power systems and how the control parameters of wind farms can affect the SSR.展开更多
可控串补(thyristor controlled series compensator,TCSC)对次同步振荡(subsynchronous oscillation,SSO)的阻尼作用受到多种因素的影响,其相关研究也结论不一。因此仅依靠TCSC自身特性来抑制SSO,其效果有待以后更进一步的研究。目前...可控串补(thyristor controlled series compensator,TCSC)对次同步振荡(subsynchronous oscillation,SSO)的阻尼作用受到多种因素的影响,其相关研究也结论不一。因此仅依靠TCSC自身特性来抑制SSO,其效果有待以后更进一步的研究。目前有必要从主动抑制的方向出发,研究TCSC的次同步振荡附加阻尼控制,为SSO的抑制提供更可靠的保障。基于机电扭振互作用的机制,对抑制SSO的原理进行分析,提出一种基于相位补偿原理的TCSC次同步振荡附加阻尼控制方法。针对某一实际串补系统,基于动态相量法对其建模,通过小干扰稳定分析,比较TCSC附加阻尼控制加入前后的模态阻尼比。分析结果表明:在该控制下,系统阻尼增强,并在各模态扭振频率下均呈现正阻尼,时域仿真也验证了控制的有效性。展开更多
This paper performs a study on three-way subsynchronous torsional interactions(SSTI)between a hybrid dual-infeed high-voltage direct current(HVDC)system and a nuclear generator.The test case is based on the French IFA...This paper performs a study on three-way subsynchronous torsional interactions(SSTI)between a hybrid dual-infeed high-voltage direct current(HVDC)system and a nuclear generator.The test case is based on the French IFA2000 line commutated converter(LCC)HVDC(2 GW)and the new Eleclink modular multilevel converter(MMC)HVDC(1 GW)interacting with the Gravelines generator(1 GW).The analysis is performed by the means of the eigenvalue stability assessment on an analytical model,while the accuracy of the conclusions is verified using the detailed non-linear electromegnetic transient program(EMTP)model.The study shows that the dual-infeed system may introduce higher risk of the SSTI compared with the point-to-point HVDC systems.It shows that MMC operating as static synchronous compensator(STATCOM)may further reduce the torsional damping at 6.3 Hz mode.This conclusion may be unexpected since it is known fact from literature that STATCOM has a beneficial impact on the transient performance of LCC.Further studies show that in a sequential HVDC loading,it may be beneficial to load the MMC HVDC first.Also,the risk of the SSTI may be minimized by changing HVDC controller gains,in particular,by increasing phaselocked-loop(PLL)gains on the LCC rectifier.展开更多
Theoretical and experimental research has been performed on the interaction curves and stress paths of crystalline polymeric materials PE and POM under tensile-torsional stress with a linearly intensifying model and i...Theoretical and experimental research has been performed on the interaction curves and stress paths of crystalline polymeric materials PE and POM under tensile-torsional stress with a linearly intensifying model and in terms of the yield points undergoing Von Mises criterion.展开更多
文摘With more and more wind power generation integrated into power grids to replace the conventional turbine-generator (T-G) units,how the subsynchronous resonance (SSR) of conventional T-G units is affected becomes an important technical issue.In this paper,a group of T-G units are interconnected with a series compensated transmission line,and some units are substituted by a nearby DFIG-based wind farm (WF).Under such circumstances,the SSR of power systems would change accordingly.This paper establishes the mathematical model to analyze the torsional interaction (TI) and the induction generator effect of the T-G units.Both eigenvalue analysis and time domain simulations demonstrate the impact of DFIG-based WF on SSR of power systems and how the control parameters of wind farms can affect the SSR.
文摘可控串补(thyristor controlled series compensator,TCSC)对次同步振荡(subsynchronous oscillation,SSO)的阻尼作用受到多种因素的影响,其相关研究也结论不一。因此仅依靠TCSC自身特性来抑制SSO,其效果有待以后更进一步的研究。目前有必要从主动抑制的方向出发,研究TCSC的次同步振荡附加阻尼控制,为SSO的抑制提供更可靠的保障。基于机电扭振互作用的机制,对抑制SSO的原理进行分析,提出一种基于相位补偿原理的TCSC次同步振荡附加阻尼控制方法。针对某一实际串补系统,基于动态相量法对其建模,通过小干扰稳定分析,比较TCSC附加阻尼控制加入前后的模态阻尼比。分析结果表明:在该控制下,系统阻尼增强,并在各模态扭振频率下均呈现正阻尼,时域仿真也验证了控制的有效性。
基金supported by Réseau de Transport d’électricitéof France。
文摘This paper performs a study on three-way subsynchronous torsional interactions(SSTI)between a hybrid dual-infeed high-voltage direct current(HVDC)system and a nuclear generator.The test case is based on the French IFA2000 line commutated converter(LCC)HVDC(2 GW)and the new Eleclink modular multilevel converter(MMC)HVDC(1 GW)interacting with the Gravelines generator(1 GW).The analysis is performed by the means of the eigenvalue stability assessment on an analytical model,while the accuracy of the conclusions is verified using the detailed non-linear electromegnetic transient program(EMTP)model.The study shows that the dual-infeed system may introduce higher risk of the SSTI compared with the point-to-point HVDC systems.It shows that MMC operating as static synchronous compensator(STATCOM)may further reduce the torsional damping at 6.3 Hz mode.This conclusion may be unexpected since it is known fact from literature that STATCOM has a beneficial impact on the transient performance of LCC.Further studies show that in a sequential HVDC loading,it may be beneficial to load the MMC HVDC first.Also,the risk of the SSTI may be minimized by changing HVDC controller gains,in particular,by increasing phaselocked-loop(PLL)gains on the LCC rectifier.
文摘Theoretical and experimental research has been performed on the interaction curves and stress paths of crystalline polymeric materials PE and POM under tensile-torsional stress with a linearly intensifying model and in terms of the yield points undergoing Von Mises criterion.