BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacia...BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen 展开更多
A novel mesa ultra-thin base AlGaAs/GaAs HBT is designed and fabricated with wet chemical selective etch technique and monitor electrode technique. It has a particular and obvious voltage-controlled NDR whose PVCR is ...A novel mesa ultra-thin base AlGaAs/GaAs HBT is designed and fabricated with wet chemical selective etch technique and monitor electrode technique. It has a particular and obvious voltage-controlled NDR whose PVCR is larger than 120. By use of device simulation,the cause of NDR is that increasing collector voltage makes the ultrathin base reach through and the device transforms from a bipolar state to a bulk barrier state. In addition, the simulated cutoff frequency is about 60-80GHz.展开更多
基金a grant fromTackle Key Problems in Sci-ence and Technology of FoshanCity, No. 200505075
文摘BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen
文摘A novel mesa ultra-thin base AlGaAs/GaAs HBT is designed and fabricated with wet chemical selective etch technique and monitor electrode technique. It has a particular and obvious voltage-controlled NDR whose PVCR is larger than 120. By use of device simulation,the cause of NDR is that increasing collector voltage makes the ultrathin base reach through and the device transforms from a bipolar state to a bulk barrier state. In addition, the simulated cutoff frequency is about 60-80GHz.