A novel method for the determination of vitamin C(Vc) is proposed in this article. After the reaction with Folin-Ciocalteau reagent at ambient temperature, Vc solution was scanned at 750--1100 nm, and its first-orde...A novel method for the determination of vitamin C(Vc) is proposed in this article. After the reaction with Folin-Ciocalteau reagent at ambient temperature, Vc solution was scanned at 750--1100 nm, and its first-order derivative spectrum were obtained from the original spectrum. The values of derivative selected at 995 nm were used for determination. It was proved that Vc could quickly react with Folin-Ciocalteau reagent within 5 min and the product was quite stable for a long time. The conditions required for this method is not very complicated, its precision and accuracy are similar to those of the iodometric titration described in Chinese Pharmacopoeia, and the limit of detection is 0.312 μg/mL. The determination of the results of vitamin C tablet, pill, and injection demonstrates that this method has wide pharmaceutical applications.展开更多
[ Objective ] The study aimed to discuss the optimal conditions for the treatment of enzymolysis wastewater by centrifugation - coagu- lation - Fenton reagent oxidation - adsorption process. [ Metbod] According to the...[ Objective ] The study aimed to discuss the optimal conditions for the treatment of enzymolysis wastewater by centrifugation - coagu- lation - Fenton reagent oxidation - adsorption process. [ Metbod] According to the water-quality characteristics of wastewater from a heparin so- dium production factory of Jiangsu Province, enzymolysis wastewater was segregated from intestinal lavage wastewater and treated through cen- trifugation- coagulation- Fenton reagent oxidation-adsorption process, and the optimal technical parameters were determined. E Resultl After enzymolysis wastewater was centrifuged at a speed of 4 000 rpm, 0.6 g/L CTS as the coagulant was added to the supematant. Hereafter, pH of the coagulated effluent was adjusted to 3, and then 1.5% (V/V) H2O2 was added to the coagulated effluent; a certain amount of ferrous sul- fate (n H2O2-.n FeSO4 . 7H2O =8:1 ) was added to the mixture; the reaction conducted for 30 min, and then solution pH was adjusted to about 9. Finally, the oxidized effluent flowed through a resin red until the adsorptive capacity reached 240 BV, and COD of the effluent water was lower than 100 mg/L, meeting the Grade-I standard of Comprehensive Discharge Standard of Sewage (GB8978-1996). [Condusio] The research could provide a new process for the treatment of enzymolysis wastewater.展开更多
基金Natural Science Foundation of Jilin Province, China(No.200305502)
文摘A novel method for the determination of vitamin C(Vc) is proposed in this article. After the reaction with Folin-Ciocalteau reagent at ambient temperature, Vc solution was scanned at 750--1100 nm, and its first-order derivative spectrum were obtained from the original spectrum. The values of derivative selected at 995 nm were used for determination. It was proved that Vc could quickly react with Folin-Ciocalteau reagent within 5 min and the product was quite stable for a long time. The conditions required for this method is not very complicated, its precision and accuracy are similar to those of the iodometric titration described in Chinese Pharmacopoeia, and the limit of detection is 0.312 μg/mL. The determination of the results of vitamin C tablet, pill, and injection demonstrates that this method has wide pharmaceutical applications.
基金Supported by the Project of Practical Innovation Training Program of Undergraduates in Jiangsu Province in 2012(232)Project of Visiting Engineers of Nanjing College of Chemical Technology in 2012
文摘[ Objective ] The study aimed to discuss the optimal conditions for the treatment of enzymolysis wastewater by centrifugation - coagu- lation - Fenton reagent oxidation - adsorption process. [ Metbod] According to the water-quality characteristics of wastewater from a heparin so- dium production factory of Jiangsu Province, enzymolysis wastewater was segregated from intestinal lavage wastewater and treated through cen- trifugation- coagulation- Fenton reagent oxidation-adsorption process, and the optimal technical parameters were determined. E Resultl After enzymolysis wastewater was centrifuged at a speed of 4 000 rpm, 0.6 g/L CTS as the coagulant was added to the supematant. Hereafter, pH of the coagulated effluent was adjusted to 3, and then 1.5% (V/V) H2O2 was added to the coagulated effluent; a certain amount of ferrous sul- fate (n H2O2-.n FeSO4 . 7H2O =8:1 ) was added to the mixture; the reaction conducted for 30 min, and then solution pH was adjusted to about 9. Finally, the oxidized effluent flowed through a resin red until the adsorptive capacity reached 240 BV, and COD of the effluent water was lower than 100 mg/L, meeting the Grade-I standard of Comprehensive Discharge Standard of Sewage (GB8978-1996). [Condusio] The research could provide a new process for the treatment of enzymolysis wastewater.