In recent years, with the growth of wind energy resources,the capability of wind farms to damp low-frequency oscillations(LFOs) has provided a notable advantage for the stabilityenhancement of the modern power grid. M...In recent years, with the growth of wind energy resources,the capability of wind farms to damp low-frequency oscillations(LFOs) has provided a notable advantage for the stabilityenhancement of the modern power grid. Meanwhile, owingto variations in the power system operating point (OP), thedamping characteristics of LFOs may be affected adversely. Inthis respect, this paper presents a coordinated robust proportional-integral-derivative (PID) based damping control approachfor permanent magnet synchronous generators (PMSGs)to effectively stabilize LFOs, while considering power system operationaluncertainties in the form of a polytopic model constructedby linearizing the power system under a given set ofOPs. The proposed approach works by modulating the DC-linkvoltage control loop of the grid-side converter (GSC) via a supplementaryPID controller, which is synthesized by transformingthe design problem into H-infinity static output feedback(SOF) control methodology. The solution of H-infinity SOF controlproblem involves satisfying linear matrix inequality (LMI)constraints based on the parameter-dependent Lyapunov functionto ensure asymptotic stability such that the minimal H-infinityperformance objective is simultaneously accomplished forthe entire polytope. The coordinated damping controllers forthe multiple wind farms are then designed sequentially by usingthe proposed approach. Eigenvalue analysis confirms the improveddamping characteristics of the closed-loop system forseveral representative OPs. Afterward, the simulation results, includingthe performance comparison with existing approaches,validate the higher robustness of the proposed approach for awide range of operating scenarios.展开更多
Synchronous output of one beam line's two megawatt hot cathode bucket ion sources is required when Neutral Beam Injector (NBI) works on the Experimental Advanced Supercon- ducting Tokamak (EAST). Neutral Beam Inj...Synchronous output of one beam line's two megawatt hot cathode bucket ion sources is required when Neutral Beam Injector (NBI) works on the Experimental Advanced Supercon- ducting Tokamak (EAST). Neutral Beam Injector Control System (NBICS) realizes synchronous output and asynchronous output of two ion sources with network communication and hardware triggers. And the synchronous time can be set by operator. In synchronous mode, two megawatt hot cathode bucket ion sources can produce neutral beams at any relative time with higher energy than two sources' asynchronous output. Two megawatt hot cathode bucket ion sources' synchronous output makes an important contribution to NBI system of 4-8 MW with 10-100 s pulse length and provides more and better parameters for EAST physical experiments.展开更多
基金supported by the Major Program of National Natural Science Foundation of China(No.U2166601)the General Program of National Natural Science Foundation of China(No.52077196).
文摘In recent years, with the growth of wind energy resources,the capability of wind farms to damp low-frequency oscillations(LFOs) has provided a notable advantage for the stabilityenhancement of the modern power grid. Meanwhile, owingto variations in the power system operating point (OP), thedamping characteristics of LFOs may be affected adversely. Inthis respect, this paper presents a coordinated robust proportional-integral-derivative (PID) based damping control approachfor permanent magnet synchronous generators (PMSGs)to effectively stabilize LFOs, while considering power system operationaluncertainties in the form of a polytopic model constructedby linearizing the power system under a given set ofOPs. The proposed approach works by modulating the DC-linkvoltage control loop of the grid-side converter (GSC) via a supplementaryPID controller, which is synthesized by transformingthe design problem into H-infinity static output feedback(SOF) control methodology. The solution of H-infinity SOF controlproblem involves satisfying linear matrix inequality (LMI)constraints based on the parameter-dependent Lyapunov functionto ensure asymptotic stability such that the minimal H-infinityperformance objective is simultaneously accomplished forthe entire polytope. The coordinated damping controllers forthe multiple wind farms are then designed sequentially by usingthe proposed approach. Eigenvalue analysis confirms the improveddamping characteristics of the closed-loop system forseveral representative OPs. Afterward, the simulation results, includingthe performance comparison with existing approaches,validate the higher robustness of the proposed approach for awide range of operating scenarios.
文摘Synchronous output of one beam line's two megawatt hot cathode bucket ion sources is required when Neutral Beam Injector (NBI) works on the Experimental Advanced Supercon- ducting Tokamak (EAST). Neutral Beam Injector Control System (NBICS) realizes synchronous output and asynchronous output of two ion sources with network communication and hardware triggers. And the synchronous time can be set by operator. In synchronous mode, two megawatt hot cathode bucket ion sources can produce neutral beams at any relative time with higher energy than two sources' asynchronous output. Two megawatt hot cathode bucket ion sources' synchronous output makes an important contribution to NBI system of 4-8 MW with 10-100 s pulse length and provides more and better parameters for EAST physical experiments.