期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
悬索及其索网在高温(火灾)作用下的计算 被引量:5
1
作者 周焕廷 李国强 罗永峰 《工业建筑》 CSCD 北大核心 2009年第2期106-108,127,共4页
对悬索及其双曲索网结构在索张紧状态下发生火灾时结构的反应特点进行分析。在节点荷载作用下,悬索及其双曲索网的面内位移相对于面外位移来说是一个较小量,可以忽略;且高温作用下索网结构具有"卸载"的特性,据此对悬索及其索... 对悬索及其双曲索网结构在索张紧状态下发生火灾时结构的反应特点进行分析。在节点荷载作用下,悬索及其双曲索网的面内位移相对于面外位移来说是一个较小量,可以忽略;且高温作用下索网结构具有"卸载"的特性,据此对悬索及其索网结构在荷载作用同时经受高温作用时结构反应进行理论推导,同时,考虑了材料和索网结构的几何非线性问题。算例表明,该方法正确、简便,精度满足工程要求。 展开更多
关键词 双曲索网 火灾反应 简化算法 双重非线性
原文传递
Temperature and structural responses of a single-section utility tunnel throughout fire exposure
2
作者 Yanmin YANG Ying XIONG +3 位作者 Yongqing LI Xiangkun MENG Peng WANG Tianyuan CAI 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2022年第10期1351-1364,共14页
In this study,fire tests of four single-section scaled-down utility tunnels were conducted.By analyzing temperature and structural responses of the utility tunnel throughout the fire exposure,the effects on the fire b... In this study,fire tests of four single-section scaled-down utility tunnels were conducted.By analyzing temperature and structural responses of the utility tunnel throughout the fire exposure,the effects on the fire behavior of two different construction methods,cast-in-situ and prefabricated,and of two different materials,ordinary concrete and full lightweight concrete,were explored.The results of the study showed that the shear failure of the cast-in-situ utility tunnel occurred at the end of the top or bottom plate,and the failure of the prefabricated utility tunnel occurred at the junction of the prefabricated member and post-cast concrete.As the temperature increased,the temperature gradient along the thickness direction of the tunnel became apparent.The maximum temperature difference between the inner and outer wall surfaces was 531.7°C.The highest temperature occurred in the cooling stage after stopping the heating,which provided a reference for the fire protection design and rescue of the utility tunnel.The displacement of the top plate of the prefabricated utility tunnel was 16.8 mm,which was 41.8%larger than that of the cast-in-situ utility tunnel.The bearing capacities of the ordinary concrete utility tunnel and full lightweight concrete utility tunnel after the fire loss were 27%and 16.8%,respectively.The full lightweight concrete utility tunnel exhibited good ductility and fire resistance and high collapse resistance. 展开更多
关键词 full lightweight concrete construction methods temperature response structural response fire test
原文传递
双曲索网结构抗火极限承载力影响因素分析 被引量:4
3
作者 周焕廷 李国强 《钢结构》 2005年第5期86-89,共4页
对双曲抛物面索网结构利用非线性有限元方法对找形、常温下结构受载计算及其火灾反应的过程等进行详细的分析研究。利用通用有限元程序ANSYS对两种典型的索网结构进行了抗火研究,通过影响抗火性能的相关参数分析,发现影响此种形式索网... 对双曲抛物面索网结构利用非线性有限元方法对找形、常温下结构受载计算及其火灾反应的过程等进行详细的分析研究。利用通用有限元程序ANSYS对两种典型的索网结构进行了抗火研究,通过影响抗火性能的相关参数分析,发现影响此种形式索网抗火性能的主要因素是荷载比与预应力比的大小。该结果可供索网结构抗火设计时参考。 展开更多
关键词 双曲索网结构 抗火性能 极限承载力 建筑结构 弹性模量
下载PDF
火灾环境下钢结构力学响应行为研究进展 被引量:1
4
作者 郭相凯 汪金辉 +1 位作者 陈科烨 杨宇鹏 《消防技术与产品信息》 2018年第8期18-23,共6页
对火灾模拟与钢结构热响应行为相关研究成果进行了调研,主要对火灾温度场、结构热环境下力学响应行为、钢结构抗火等方面的研究进展和现状进行了分析、梳理和总结;从工程实际出发,探讨了火灾环境下钢结构抗火领域需要解决的主要问题。
关键词 火灾 结构力学响应 热—力耦合 钢结构抗火
原文传递
上一页 1 下一页 到第