The paper concerns with the relationship between cavitation inception andSound Pressure Level (SPL). A case study for the Xiaolangdi Hydro-project was taken as a typicalexample, which demonstrated the standard criteri...The paper concerns with the relationship between cavitation inception andSound Pressure Level (SPL). A case study for the Xiaolangdi Hydro-project was taken as a typicalexample, which demonstrated the standard criterion of SPL indicating cavitation inception.Cavitation inception of an orifice plate used for energy dissipation in a tunnel spillway waswitnessed and verified both in model test and prototype observation. A design criterion was proposedfor a cavitation-free hydraulic structure which can be served as a reference for designers as wellas researchers. Consequently, scale effects were discussed with an aim at suggesting an appropriatefactor of safety in design.展开更多
文摘The paper concerns with the relationship between cavitation inception andSound Pressure Level (SPL). A case study for the Xiaolangdi Hydro-project was taken as a typicalexample, which demonstrated the standard criterion of SPL indicating cavitation inception.Cavitation inception of an orifice plate used for energy dissipation in a tunnel spillway waswitnessed and verified both in model test and prototype observation. A design criterion was proposedfor a cavitation-free hydraulic structure which can be served as a reference for designers as wellas researchers. Consequently, scale effects were discussed with an aim at suggesting an appropriatefactor of safety in design.