A fast radial scanning probe system was constructed for the Keda Torus eXperiment(KTX)to measure the profiles of boundary plasma parameters such as floating potential,electron density,temperature,transport fluxes,etc....A fast radial scanning probe system was constructed for the Keda Torus eXperiment(KTX)to measure the profiles of boundary plasma parameters such as floating potential,electron density,temperature,transport fluxes,etc.The scanning probe system is driven by slow and fast motion mechanisms,corresponding to the stand-by movement of a stepping motor and the fast scanning movement of a high-torque servo-motor,respectively.In fast scanning,the scanner drives the probe radially up to 20 cm at a maximum velocity of 4.0 m s-1.A noncontact magnetic grating ruler with a high spatial resolution of 5μm is used for the displacement measurement.New scanning probe can reach the center of plasmas rapidly.The comparison of plasma floating potential profiles obtained by a fixed radial rake probe and the single scanning probe suggests that the high-speed scanning probe system is reliable for measuring edge plasma parameter profiles on the KTX device.展开更多
Human saccade is a dynamic process of information pursuit. There are many methods using either global context or local context cues to model human saccadic scan-paths. In contrast to them, this paper introduces a mode...Human saccade is a dynamic process of information pursuit. There are many methods using either global context or local context cues to model human saccadic scan-paths. In contrast to them, this paper introduces a model for gaze movement control using both global and local cues. To test the performance of this model, an experiment is done to collect human eye movement data by using an SMI iVIEW X Hi-Speed eye tracker with a sampling rate of 1250 Hz. The experiment used a two-by-four mixed design with the location of the targets and the four initial positions. We compare the saccadic scan-paths generated by the proposed model against human eye movement data on a face benchmark dataset. Experimental results demonstrate that the simulated scan-paths by the proposed model are similar to human saccades in term of the fixation order, Hausdorff distance, and prediction accuracy for both static fixation locations and dynamic scan-paths.展开更多
基金supported by the National Magnetic Confinement Fusion Science Program of China(No.2017YFE0301700)National Natural Science Foundation of China(No.11635008).
文摘A fast radial scanning probe system was constructed for the Keda Torus eXperiment(KTX)to measure the profiles of boundary plasma parameters such as floating potential,electron density,temperature,transport fluxes,etc.The scanning probe system is driven by slow and fast motion mechanisms,corresponding to the stand-by movement of a stepping motor and the fast scanning movement of a high-torque servo-motor,respectively.In fast scanning,the scanner drives the probe radially up to 20 cm at a maximum velocity of 4.0 m s-1.A noncontact magnetic grating ruler with a high spatial resolution of 5μm is used for the displacement measurement.New scanning probe can reach the center of plasmas rapidly.The comparison of plasma floating potential profiles obtained by a fixed radial rake probe and the single scanning probe suggests that the high-speed scanning probe system is reliable for measuring edge plasma parameter profiles on the KTX device.
文摘Human saccade is a dynamic process of information pursuit. There are many methods using either global context or local context cues to model human saccadic scan-paths. In contrast to them, this paper introduces a model for gaze movement control using both global and local cues. To test the performance of this model, an experiment is done to collect human eye movement data by using an SMI iVIEW X Hi-Speed eye tracker with a sampling rate of 1250 Hz. The experiment used a two-by-four mixed design with the location of the targets and the four initial positions. We compare the saccadic scan-paths generated by the proposed model against human eye movement data on a face benchmark dataset. Experimental results demonstrate that the simulated scan-paths by the proposed model are similar to human saccades in term of the fixation order, Hausdorff distance, and prediction accuracy for both static fixation locations and dynamic scan-paths.