A heat transfer model of furnace roller cooling process was established based on analysis of furnace roller's structure. The complicated model was solved with iteration planning algorithm based on Newton search. The ...A heat transfer model of furnace roller cooling process was established based on analysis of furnace roller's structure. The complicated model was solved with iteration planning algorithm based on Newton search. The model is proved logical and credible by comparing calculated results and measured data. Then, the relationship between water flow velocity, inlet water temperature, furnace temperature and roller cross section temperature, outlet water temperature, water temperature rise, cooling water heat absorption was studied. The conclusions and recommendations are mainly as follows: l) Cooling water temperature rise decreases with the increase of water flow velocity, but it has small relationship with inlet water temperature; 2) In order to get little water scale, inlet water temperature should be controlled below 30 ℃. 3) The cooling water flow velocity should be greater than critical velocity. The critical velocity is 0.07 m/s and water flow velocity should be controlled within 0.4-0.8 m/s. Within this velocity range, water cooling efficiency is high and water temperature rise is little. If cooling water velocity increases again, heat loss will increase, leading to energy wasting.展开更多
As to the horizontal stripes defect which exist on the surface of the high-grade automotive panels in continuous annealing process, an effective comprehensive control method is proposed on the basis of full considerat...As to the horizontal stripes defect which exist on the surface of the high-grade automotive panels in continuous annealing process, an effective comprehensive control method is proposed on the basis of full consideration of the equipment and technological features of continuous annealing line. With five field tests as basis, the generation mechanism of the defect was analysised in detail and the comprehensive control measures were put forward. According to actual situation, a detailed technical plan was worked out .Then the relevant technologies were applied to a 1850 continuous annealing line. The statistics shows that this program acquired good effects. The incidence of horizontal stripes defect decreased from 100% to 2.78%. Meanwhile, the surface quality of strip also improved effectively, which created a larger economic benefit.展开更多
基金Project(2010CB630800) supported by the National Basic Research Program of China
文摘A heat transfer model of furnace roller cooling process was established based on analysis of furnace roller's structure. The complicated model was solved with iteration planning algorithm based on Newton search. The model is proved logical and credible by comparing calculated results and measured data. Then, the relationship between water flow velocity, inlet water temperature, furnace temperature and roller cross section temperature, outlet water temperature, water temperature rise, cooling water heat absorption was studied. The conclusions and recommendations are mainly as follows: l) Cooling water temperature rise decreases with the increase of water flow velocity, but it has small relationship with inlet water temperature; 2) In order to get little water scale, inlet water temperature should be controlled below 30 ℃. 3) The cooling water flow velocity should be greater than critical velocity. The critical velocity is 0.07 m/s and water flow velocity should be controlled within 0.4-0.8 m/s. Within this velocity range, water cooling efficiency is high and water temperature rise is little. If cooling water velocity increases again, heat loss will increase, leading to energy wasting.
文摘As to the horizontal stripes defect which exist on the surface of the high-grade automotive panels in continuous annealing process, an effective comprehensive control method is proposed on the basis of full consideration of the equipment and technological features of continuous annealing line. With five field tests as basis, the generation mechanism of the defect was analysised in detail and the comprehensive control measures were put forward. According to actual situation, a detailed technical plan was worked out .Then the relevant technologies were applied to a 1850 continuous annealing line. The statistics shows that this program acquired good effects. The incidence of horizontal stripes defect decreased from 100% to 2.78%. Meanwhile, the surface quality of strip also improved effectively, which created a larger economic benefit.