After giving a short review of the methods used for detecting and monitoring in general systems, this paper describes the way of communication between computer and Computer Numerical Control (CNC) Machining Center (MC...After giving a short review of the methods used for detecting and monitoring in general systems, this paper describes the way of communication between computer and Computer Numerical Control (CNC) Machining Center (MC). Based on these, the paper addresses the means of performing in cycle measurement for manufacturing quality, provides an approach of improving the state of manufacturing process by achieving the real time change of control parameters according to the level of manufacturing process, and discusses the technique of implementing in process dimensional errors compensation corresponding to the in cycle measurement. The results of the experiments show that the frame design is successful and the operation is reliable. The system is taking shape nowadays.展开更多
This study presents the results of the preliminary tests performed using a kerma-area product (KAP) meter in order to verify its usefulness as a monitor chamber in a clinical X ray system, which will be used in ioniza...This study presents the results of the preliminary tests performed using a kerma-area product (KAP) meter in order to verify its usefulness as a monitor chamber in a clinical X ray system, which will be used in ionization chambers’ quality control program. The tests performed were repeatability, surface measurement uniformity, linearity with tube current, measurement variation changing the distance and field size, KAP chamber radiation attenuation, and energy dependence. The KAP meter has presented a good repeatability (a maximum variation of 0.4%);its surface has a homogeneous response (a maximum variation of 1.0% among the different irradiated regions);the response is linear with the tube current and the variation of the PKA along the distance is less than 3.43%. On the other hand, the results obtained for chamber attenuation and energy dependence show that some corrections must be applied when the measurements are made. The results have shown a good performance of the KAP meter, confirming that it is possible to use this instrument as a monitor chamber. However, it is important to highlight that some correction factors for energy dependence and chamber radiation attenuation must be considered.展开更多
文摘After giving a short review of the methods used for detecting and monitoring in general systems, this paper describes the way of communication between computer and Computer Numerical Control (CNC) Machining Center (MC). Based on these, the paper addresses the means of performing in cycle measurement for manufacturing quality, provides an approach of improving the state of manufacturing process by achieving the real time change of control parameters according to the level of manufacturing process, and discusses the technique of implementing in process dimensional errors compensation corresponding to the in cycle measurement. The results of the experiments show that the frame design is successful and the operation is reliable. The system is taking shape nowadays.
文摘This study presents the results of the preliminary tests performed using a kerma-area product (KAP) meter in order to verify its usefulness as a monitor chamber in a clinical X ray system, which will be used in ionization chambers’ quality control program. The tests performed were repeatability, surface measurement uniformity, linearity with tube current, measurement variation changing the distance and field size, KAP chamber radiation attenuation, and energy dependence. The KAP meter has presented a good repeatability (a maximum variation of 0.4%);its surface has a homogeneous response (a maximum variation of 1.0% among the different irradiated regions);the response is linear with the tube current and the variation of the PKA along the distance is less than 3.43%. On the other hand, the results obtained for chamber attenuation and energy dependence show that some corrections must be applied when the measurements are made. The results have shown a good performance of the KAP meter, confirming that it is possible to use this instrument as a monitor chamber. However, it is important to highlight that some correction factors for energy dependence and chamber radiation attenuation must be considered.