Sodium-ion batteries(SIBs)have garnered significant interest in energy storage due to their similar working mechanism to lithium ion batteries and abundant reserves of sodium resource.Exploring facile synthesis of a c...Sodium-ion batteries(SIBs)have garnered significant interest in energy storage due to their similar working mechanism to lithium ion batteries and abundant reserves of sodium resource.Exploring facile synthesis of a carbon-based anode materials with capable electrochemical performance is key to promoting the practical application of SIBs.In this work,a combination of petroleum pitch and recyclable sodium chloride is selected as the carbon source and template to obtain hard carbon(HC)anode for SIBs.Carbonization times and temperatures are optimized by assessing the sodium ion storage behavior of different HC materials.The optimized HC exhibits a remarkable capacity of over 430 mAh·g^(-1) after undergoing full activation through 500 cycles at a density of current of 0.1 A·g^(-1).Furthermore,it demonstrates an initial discharge capacity of 276 mAh·g^(-1) at a density of current of 0.5 A·g^(-1).Meanwhile,the optimized HC shows a good capacity retention(170 mAh·g^(-1) after 750 cycles)and a remarkable rate ability(166 mAh·g^(-1) at 2 A·g^(-1)).The enhanced capacity is attributed to the suitable degree of graphitization and surface area,which improve the sodium ion transport and storage.展开更多
Objective To assess the image quality and effective radiation dose of prospectively electrocardiogram-triggered high-pitch spiral acquisition (flash spiral mode)dual-source CT coronary angiography in patients with hig...Objective To assess the image quality and effective radiation dose of prospectively electrocardiogram-triggered high-pitch spiral acquisition (flash spiral mode)dual-source CT coronary angiography in patients with high heart rate(HR).Methods From 1321 consecutive patients,seventy patients with HR≥70 bpm (group A) and seventy patients with HR<70 bpm (group B) underwent CT angiography and were prospectively included in this study.The start phase for image acquisition of the most cranial slice was selected at 20%-30% of the R-R interval for group A and at 60% of the RR interval for group B.Assessed the image quality and effective radiation dose of two group.Results (1)There were no significant differences in age,sex,BMI and scan time between the two groups.(2)Image qualities:The segments with non-diagnostic image quality occurred (i.e.score 3) had no significant difference between group A and group B (2.1% vs.1.5%,P=0.48).Non-diagnostic image quality was most often found in the RCA and LCX in both groups.(3)The estimated radiation dose was on average (1.00±0.15) mSv(0.7-1.82 mSv) in group A and (1.01±0.16)mSv (0.65-1.82 mSv) in group B.Conclusions Patients with high heart rates can be performed CTCA with high-pitch spiral acquisition mode.20%-30% of the R-R interval window for data acquisition for high-pitch dual-source CTCA may probably obtain good image quality with low doses.The highest HRs are 100 bpm with good image quality.HR variability is a great effect factor of image quality.The estimated radiation dose is about 1 mSv.展开更多
Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona...Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch sp展开更多
In this work,we have prepared the hierarchically nanostructured core–shell NiCo layered double hydroxide(NiCo-LDH)nanosheets-and ZnFe_(2)O_(4) nanocubes-decorated polyacrylonitrile(PAN)/pitch-based carbon nanofibers(...In this work,we have prepared the hierarchically nanostructured core–shell NiCo layered double hydroxide(NiCo-LDH)nanosheets-and ZnFe_(2)O_(4) nanocubes-decorated polyacrylonitrile(PAN)/pitch-based carbon nanofibers(PPCNs)webs(NiCo-LDH@PPCNs as cathode and ZnFe_(2)O_(4)@PPCNs as anode materials)with the bonded network structure by a facile and scalable hydrothemal method.Herein,the low-cost pitch with lower softening point(~90℃)as co-precursor was utilized to produce the PAN/pitch-based carbon nanofibers(PPCNs)with enhanced electrical conductivity.The obtained PPCNs with pitch content of 30%(PP30CNs)electrode material delivered higher specific capacitance(~67 F g^(-1))than that(~48 F g^(-1))of the PAN-based carbon nanofibers(PCNs)at 1 A g^(-1),due to the increased electrical conductivity and lower interfacial charge transfer resistance(RCT)of~0.16 U.Further,the NiCo-LDH-decorated PP30CNs(NiCoLDH@PP30CNs)as cathode material showed superior specific capacitance of 1162 F g^(-1) at 1.0 A g^(-1) and ultra-high retention rate of 91.56%at 10 A g^(-1).The ZnFe_(2)O_(4)@PP30CNs as anode material also showed higher specific capacitance of 282 F g^(-1) at 1 A g^(-1) and good rate capability with capacitance retention of 56.73%at 10 A g^(-1).The as-fabricated asymmetric NiCo-LDH@PP30CNs//ZnFe_(2)O_(4)@PP30CNs hybrid supercapacitor device delivered a specific capacitance of~98 F g^(-1) at 1 A g^(-1) and excellent capacitance retention of~88%after 5000 charge–discharge cycles.展开更多
This paper focuses on the influence of the disturbance rejection rate(DRR)and parasitic loop parameters on the stability domain of the roll-pitch seeker's guidance system.The DRR models of the roll-pitch seeker ca...This paper focuses on the influence of the disturbance rejection rate(DRR)and parasitic loop parameters on the stability domain of the roll-pitch seeker's guidance system.The DRR models of the roll-pitch seeker caused by different types of disturbance torques and the scale deviation of different sensors are established.The optimal DRR model of the roll-pitch seeker,which contains the scale deviation model,is proposed by formula derivation.The model of the roll-pitch seeker's guidance system is established and equivalently simplified by the dimensionless method.The Lyapunov stability criterion for stability analysis of the guidance system is given by means of the passivity theorem and related definitions and lemmas.A simplified model of the roll-pitch seeker's guidance system,which is suitable for the Lyapunov stability criterion,is established by formula derivation and equivalent transformation.Three conditions that satisfy the Lyapunov stability criterion are obtained.Mathematical simulation with Nyquist plots is used to analyze the influence of different DRR parameters on the stability domain of the roll-pitch seeker's guidance system.Simulation results of this paper can provide reference for the stability analysis of systems related to the roll-pitch seeker.展开更多
基金supported by Heilongjiang Province Key R&D Program(Grant No.GA22A014).
文摘Sodium-ion batteries(SIBs)have garnered significant interest in energy storage due to their similar working mechanism to lithium ion batteries and abundant reserves of sodium resource.Exploring facile synthesis of a carbon-based anode materials with capable electrochemical performance is key to promoting the practical application of SIBs.In this work,a combination of petroleum pitch and recyclable sodium chloride is selected as the carbon source and template to obtain hard carbon(HC)anode for SIBs.Carbonization times and temperatures are optimized by assessing the sodium ion storage behavior of different HC materials.The optimized HC exhibits a remarkable capacity of over 430 mAh·g^(-1) after undergoing full activation through 500 cycles at a density of current of 0.1 A·g^(-1).Furthermore,it demonstrates an initial discharge capacity of 276 mAh·g^(-1) at a density of current of 0.5 A·g^(-1).Meanwhile,the optimized HC shows a good capacity retention(170 mAh·g^(-1) after 750 cycles)and a remarkable rate ability(166 mAh·g^(-1) at 2 A·g^(-1)).The enhanced capacity is attributed to the suitable degree of graphitization and surface area,which improve the sodium ion transport and storage.
基金grants from the Natural Science Foundation of Inner Mongolia (20110054)
文摘Objective To assess the image quality and effective radiation dose of prospectively electrocardiogram-triggered high-pitch spiral acquisition (flash spiral mode)dual-source CT coronary angiography in patients with high heart rate(HR).Methods From 1321 consecutive patients,seventy patients with HR≥70 bpm (group A) and seventy patients with HR<70 bpm (group B) underwent CT angiography and were prospectively included in this study.The start phase for image acquisition of the most cranial slice was selected at 20%-30% of the R-R interval for group A and at 60% of the RR interval for group B.Assessed the image quality and effective radiation dose of two group.Results (1)There were no significant differences in age,sex,BMI and scan time between the two groups.(2)Image qualities:The segments with non-diagnostic image quality occurred (i.e.score 3) had no significant difference between group A and group B (2.1% vs.1.5%,P=0.48).Non-diagnostic image quality was most often found in the RCA and LCX in both groups.(3)The estimated radiation dose was on average (1.00±0.15) mSv(0.7-1.82 mSv) in group A and (1.01±0.16)mSv (0.65-1.82 mSv) in group B.Conclusions Patients with high heart rates can be performed CTCA with high-pitch spiral acquisition mode.20%-30% of the R-R interval window for data acquisition for high-pitch dual-source CTCA may probably obtain good image quality with low doses.The highest HRs are 100 bpm with good image quality.HR variability is a great effect factor of image quality.The estimated radiation dose is about 1 mSv.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch sp
基金supported by the National Research Foundation of Korea grant funded by the Korea government(MSIT)(No.2020R1A2C2012356)the National Research Foundation of Korea grant funded by the Korea government(MSIT)(2020R1I1A1A01073937).
文摘In this work,we have prepared the hierarchically nanostructured core–shell NiCo layered double hydroxide(NiCo-LDH)nanosheets-and ZnFe_(2)O_(4) nanocubes-decorated polyacrylonitrile(PAN)/pitch-based carbon nanofibers(PPCNs)webs(NiCo-LDH@PPCNs as cathode and ZnFe_(2)O_(4)@PPCNs as anode materials)with the bonded network structure by a facile and scalable hydrothemal method.Herein,the low-cost pitch with lower softening point(~90℃)as co-precursor was utilized to produce the PAN/pitch-based carbon nanofibers(PPCNs)with enhanced electrical conductivity.The obtained PPCNs with pitch content of 30%(PP30CNs)electrode material delivered higher specific capacitance(~67 F g^(-1))than that(~48 F g^(-1))of the PAN-based carbon nanofibers(PCNs)at 1 A g^(-1),due to the increased electrical conductivity and lower interfacial charge transfer resistance(RCT)of~0.16 U.Further,the NiCo-LDH-decorated PP30CNs(NiCoLDH@PP30CNs)as cathode material showed superior specific capacitance of 1162 F g^(-1) at 1.0 A g^(-1) and ultra-high retention rate of 91.56%at 10 A g^(-1).The ZnFe_(2)O_(4)@PP30CNs as anode material also showed higher specific capacitance of 282 F g^(-1) at 1 A g^(-1) and good rate capability with capacitance retention of 56.73%at 10 A g^(-1).The as-fabricated asymmetric NiCo-LDH@PP30CNs//ZnFe_(2)O_(4)@PP30CNs hybrid supercapacitor device delivered a specific capacitance of~98 F g^(-1) at 1 A g^(-1) and excellent capacitance retention of~88%after 5000 charge–discharge cycles.
基金supported by the Defense Science and Technology Key Laboratory Fund of Luoyang Electro-optical Equipment Institute,Aviation Industry Corporation of China(6142504200108)。
文摘This paper focuses on the influence of the disturbance rejection rate(DRR)and parasitic loop parameters on the stability domain of the roll-pitch seeker's guidance system.The DRR models of the roll-pitch seeker caused by different types of disturbance torques and the scale deviation of different sensors are established.The optimal DRR model of the roll-pitch seeker,which contains the scale deviation model,is proposed by formula derivation.The model of the roll-pitch seeker's guidance system is established and equivalently simplified by the dimensionless method.The Lyapunov stability criterion for stability analysis of the guidance system is given by means of the passivity theorem and related definitions and lemmas.A simplified model of the roll-pitch seeker's guidance system,which is suitable for the Lyapunov stability criterion,is established by formula derivation and equivalent transformation.Three conditions that satisfy the Lyapunov stability criterion are obtained.Mathematical simulation with Nyquist plots is used to analyze the influence of different DRR parameters on the stability domain of the roll-pitch seeker's guidance system.Simulation results of this paper can provide reference for the stability analysis of systems related to the roll-pitch seeker.