Tensile tests of GH4169 alloy were performed at room temperature. Different fractions, distributions and shapes of δ phase was prepared by aging treated at 880 ℃, 930 ℃ and 980 ℃ for 5 h or 10 h. The effect of δ ...Tensile tests of GH4169 alloy were performed at room temperature. Different fractions, distributions and shapes of δ phase was prepared by aging treated at 880 ℃, 930 ℃ and 980 ℃ for 5 h or 10 h. The effect of δ phase on the mechanical pro- perties of GH4169 alloy was investigated. The results show that 0.2% yield strength and ultimate tensile strength of GH4169 alloy increase by 61 MPa and 78 MPa respectively when the fraction of δ phase increases from 2.20% to 5.21%. Then, the ultimate tensile strength remains at 1 012 MPa even when the fraction of δ phase reaches 7.56%. The fraction effect of δ phase on the strength improvement of GH4169 alloy is more significant than morphology, and the critical fraction value is 5.21%. In addition, the elongation decreases by 14.1% when the fraction of δ phase increases from 2.20% to 7.56%. Excessive needle or short rod shaped 8 ohase is resoonsible for the reduction of eloneation.展开更多
Trombe wall and phase change materials(PCMs)are two effective ways to regulate indoor thermal comfort.However,Trombe wall surfers from overheating in summer and PCMs suffer from low heat transfer rate caused by the li...Trombe wall and phase change materials(PCMs)are two effective ways to regulate indoor thermal comfort.However,Trombe wall surfers from overheating in summer and PCMs suffer from low heat transfer rate caused by the limited thermal conductivity.To compensate the shortcomings of the two methods,this paper proposed a Trombe wall system integrated with PCMs.Based on a light-weight building envelope in Changsha,China,the thermal comfort of 10 kinds of Trombe wall systems with PCMs with a melting temperature of 18-28℃ were studied.Taking the integrated indoor discomfort duration(I_(D)),integrated indoor discomfort degree-hour(I_(DH)),indoor air temperature(T_(in)),PCM liquid fraction(γ)and heat flux across wall(q)as evaluation indexes,the indoor thermal comfort was assessed in hot summer and cold winter region.Results show that the Trombe wall helped PCMs complete the phase change process effectively.Trombe wall with PCM25 next to the wall inner surface possessed the lowest annual I_(D) and I_(DH),as 2877 h and 12,974℃·h,respectively.Compared with the values in a traditional building,the I_(D) and I_(DH) were reduced by 7.01% and 14.14%.In order to give full play to the heat storage and heat release of the Trombe wall with PCMs,PCMs with phase change temperature 7℃ lower than the peak ambient temperature in summer or 8℃ higher than the winter night temperature was recommended according to regional climate conditions.展开更多
This paper discusses mineral composition and pore microstructure characteristics of water-cooled manganese slag and its effects on durability of concrete. The Mn slag has an alveolate pore structure, and the ground Mn...This paper discusses mineral composition and pore microstructure characteristics of water-cooled manganese slag and its effects on durability of concrete. The Mn slag has an alveolate pore structure, and the ground Mn slag is characterized by multiangular shape which consists of a'-C2S, C3M82, CaO.MnO-2SiOu and C2AS. Experimental results show that the Mn slag has potential hydraulic reactivity. Concrete made with Mn slag as supplementary cementitious materials (SCMs) exhibits very low strength loss and weight loss in the synthetic seawater corrosion and freezing-thawing cycle tests. The research provides useful reference for knowing about Mn slag and for applying Mn slag to improve the durability of concrete.展开更多
This study evaluates the effectiveness of phase change materials(PCMs) inside a storage tank of warm water for solar water heating(SWH) system through the theoretical simulation based on the experimental model of S.Ca...This study evaluates the effectiveness of phase change materials(PCMs) inside a storage tank of warm water for solar water heating(SWH) system through the theoretical simulation based on the experimental model of S.Canbazoglu et al.The model is explained by five fundamental equations for the calculation of various parameters like the effectiveness of PCMs,the mass of hot water,total heat content,and duration of charging.This study simulated eleven PCMs to analyze their effectiveness like Sodium hydrogen phosphate dodecahydrate(SHPD),OM 37,N-Eicosane(NE),Lauric acid(LA),Paraffin wax(PW),OM 48,Paraffin wax C_(20-33)(PW-C20-33),Sodium acetate trihydrate(SAT),Palmitic acid(PA),Myristic acid(MA),and Stearic acid(SA).Among all PCMs,the SHPD has found the highest value of effectiveness factor of 3.27.So,it is the most recommended PCM for the storage tank of the SWH system.The study also includes the melt fraction analysis of all enumerated PCMs corresponding to container materials of stainless steel,glass,aluminum mixed,tin,aluminum,and copper.This melt fraction analysis is performed by making a coding program in the FORTRAN programming language.Through the analysis,copper container material is found to have high melting rate for all PCMs so it is superior to other container materials.展开更多
Oil-air two-phase flow measurement was investigated with a Venturi and void fraction meters in this work. This paper proposes a new flow rate measurement correlation in which the effect of the velocity ratio between g...Oil-air two-phase flow measurement was investigated with a Venturi and void fraction meters in this work. This paper proposes a new flow rate measurement correlation in which the effect of the velocity ratio between gas and liquid was considered. With the pressure drop across the Venturi and the void fraction that was measured by electrical capacitance tomography apparatus, both mixture flow rate and oil flow rate could be obtained by the correlation. Experiments included bubble-, slug-, wave and annular flow with the void fraction ranging from 15% to 83%, the oil flow rate ranging from 0.97 kg/s to 1.78 kg/s, the gas flow rate ranging up to 0.018 kg/s and quality ranging nearly up to 2.0%. The root-mean-square errors of mixture mass flow rate and that of oil mass flow rate were less than 5%. Furthermore, coefficients of the correlation were modified based on flow regimes, with the results showing reduced root-mean-square errors.展开更多
基金Sponsored by the Fund of China State Key Laboratory of Advanced Processing and Recycling of Non-ferrous Metals,Lanzhou University of Technology(SKLAB02014001)
文摘Tensile tests of GH4169 alloy were performed at room temperature. Different fractions, distributions and shapes of δ phase was prepared by aging treated at 880 ℃, 930 ℃ and 980 ℃ for 5 h or 10 h. The effect of δ phase on the mechanical pro- perties of GH4169 alloy was investigated. The results show that 0.2% yield strength and ultimate tensile strength of GH4169 alloy increase by 61 MPa and 78 MPa respectively when the fraction of δ phase increases from 2.20% to 5.21%. Then, the ultimate tensile strength remains at 1 012 MPa even when the fraction of δ phase reaches 7.56%. The fraction effect of δ phase on the strength improvement of GH4169 alloy is more significant than morphology, and the critical fraction value is 5.21%. In addition, the elongation decreases by 14.1% when the fraction of δ phase increases from 2.20% to 7.56%. Excessive needle or short rod shaped 8 ohase is resoonsible for the reduction of eloneation.
基金supported by the National Key Research and Devel-opment Program of China(2018YFE0111200)the National Natural Science Foundation of China(52078053,51608051)+4 种基金the Science and Technology Department of Hunan(2019JJ30027,2020GK4057)the Changsha City Fund for Distinguished and Innovative Young Scholars(kq2106036)the Hunan Provincial Science and Technology Depart-ment(2020WK2012,2021JJ40584)the Education Department of Hu-nan Province(19C0073)the Chenzhou Municipal Science and Tech-nology Bureau(2021SFQ01).
文摘Trombe wall and phase change materials(PCMs)are two effective ways to regulate indoor thermal comfort.However,Trombe wall surfers from overheating in summer and PCMs suffer from low heat transfer rate caused by the limited thermal conductivity.To compensate the shortcomings of the two methods,this paper proposed a Trombe wall system integrated with PCMs.Based on a light-weight building envelope in Changsha,China,the thermal comfort of 10 kinds of Trombe wall systems with PCMs with a melting temperature of 18-28℃ were studied.Taking the integrated indoor discomfort duration(I_(D)),integrated indoor discomfort degree-hour(I_(DH)),indoor air temperature(T_(in)),PCM liquid fraction(γ)and heat flux across wall(q)as evaluation indexes,the indoor thermal comfort was assessed in hot summer and cold winter region.Results show that the Trombe wall helped PCMs complete the phase change process effectively.Trombe wall with PCM25 next to the wall inner surface possessed the lowest annual I_(D) and I_(DH),as 2877 h and 12,974℃·h,respectively.Compared with the values in a traditional building,the I_(D) and I_(DH) were reduced by 7.01% and 14.14%.In order to give full play to the heat storage and heat release of the Trombe wall with PCMs,PCMs with phase change temperature 7℃ lower than the peak ambient temperature in summer or 8℃ higher than the winter night temperature was recommended according to regional climate conditions.
基金the National Basic Research Program(973) of China(No.2009CB326200)the Guangxi Technology and Science Development Program (Nos.11107024-4,0842003-17 and 0842003-3A)
文摘This paper discusses mineral composition and pore microstructure characteristics of water-cooled manganese slag and its effects on durability of concrete. The Mn slag has an alveolate pore structure, and the ground Mn slag is characterized by multiangular shape which consists of a'-C2S, C3M82, CaO.MnO-2SiOu and C2AS. Experimental results show that the Mn slag has potential hydraulic reactivity. Concrete made with Mn slag as supplementary cementitious materials (SCMs) exhibits very low strength loss and weight loss in the synthetic seawater corrosion and freezing-thawing cycle tests. The research provides useful reference for knowing about Mn slag and for applying Mn slag to improve the durability of concrete.
基金the University Grants Commission (UGC) & Ministry of Human Resource Development (MHRD),Government of India,New Delhi for providing the Junior Research Fellowship (JRF)the Council of Science and Technology,UP (Reference No, CST 3012-dt.26-12-2016) for providing research grants to carry out the work at the institute。
文摘This study evaluates the effectiveness of phase change materials(PCMs) inside a storage tank of warm water for solar water heating(SWH) system through the theoretical simulation based on the experimental model of S.Canbazoglu et al.The model is explained by five fundamental equations for the calculation of various parameters like the effectiveness of PCMs,the mass of hot water,total heat content,and duration of charging.This study simulated eleven PCMs to analyze their effectiveness like Sodium hydrogen phosphate dodecahydrate(SHPD),OM 37,N-Eicosane(NE),Lauric acid(LA),Paraffin wax(PW),OM 48,Paraffin wax C_(20-33)(PW-C20-33),Sodium acetate trihydrate(SAT),Palmitic acid(PA),Myristic acid(MA),and Stearic acid(SA).Among all PCMs,the SHPD has found the highest value of effectiveness factor of 3.27.So,it is the most recommended PCM for the storage tank of the SWH system.The study also includes the melt fraction analysis of all enumerated PCMs corresponding to container materials of stainless steel,glass,aluminum mixed,tin,aluminum,and copper.This melt fraction analysis is performed by making a coding program in the FORTRAN programming language.Through the analysis,copper container material is found to have high melting rate for all PCMs so it is superior to other container materials.
基金Project (No. 2001AA413210) supported by the Hi-Tech Researchand Development Program (863) of China
文摘Oil-air two-phase flow measurement was investigated with a Venturi and void fraction meters in this work. This paper proposes a new flow rate measurement correlation in which the effect of the velocity ratio between gas and liquid was considered. With the pressure drop across the Venturi and the void fraction that was measured by electrical capacitance tomography apparatus, both mixture flow rate and oil flow rate could be obtained by the correlation. Experiments included bubble-, slug-, wave and annular flow with the void fraction ranging from 15% to 83%, the oil flow rate ranging from 0.97 kg/s to 1.78 kg/s, the gas flow rate ranging up to 0.018 kg/s and quality ranging nearly up to 2.0%. The root-mean-square errors of mixture mass flow rate and that of oil mass flow rate were less than 5%. Furthermore, coefficients of the correlation were modified based on flow regimes, with the results showing reduced root-mean-square errors.