A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of ...A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of the two compared signals. It utilizes the regular phase shift characteristics between the signals. The resolution of the measurement approach can reach 10^-13/s at 5 MHz, and the self-calibration resolution can achieve 10^-14/s in the comparison between 10 MHz and 100 MHz, or even can reach 10^-15/s in the comparison between 10 MHz and 190 MHz. This method implies significant progress in the development of the high precision frequency standard comparison technology.展开更多
The phase change between periodic signals is regular. Research on the regular phenomenon between periodic signals is helpful to improve the precision of some measurements and develop some new measurement methods. So i...The phase change between periodic signals is regular. Research on the regular phenomenon between periodic signals is helpful to improve the precision of some measurements and develop some new measurement methods. So it is necessary to analyze the characteristics of the greatest common factor frequency and the least common multiple period universally existing in periodic signals. The regulation of the quantitative phase shift resolution between periodic signals is presented.The cause of difference in phase characteristics between periodic signals is explained well. In this paper we propose different application prospects based on the regular phenomenon between periodic signals, with focusing on the methods for high precision frequency measurement and transient stability measurement. The experimental results are satisfactory.展开更多
基金supported by the National Natural Science Foundation of China (Grant Nos.60772135 and 10978017)the Open Fund of Key Laboratory of Precision Navigation and Technology,National Time Service Center,Chinese Academy of Sciences (Grant No.2009PNTT10)the Fundamental Research Funds for the Central Universities,China (Grant No.JY10000905015)
文摘A method for super high resolution comparison measurement is proposed in this paper with a comparison between the frequency standards of different nominal frequencies, which is based on phase coincidence detection of the two compared signals. It utilizes the regular phase shift characteristics between the signals. The resolution of the measurement approach can reach 10^-13/s at 5 MHz, and the self-calibration resolution can achieve 10^-14/s in the comparison between 10 MHz and 100 MHz, or even can reach 10^-15/s in the comparison between 10 MHz and 190 MHz. This method implies significant progress in the development of the high precision frequency standard comparison technology.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.10978017 and 61201288)
文摘The phase change between periodic signals is regular. Research on the regular phenomenon between periodic signals is helpful to improve the precision of some measurements and develop some new measurement methods. So it is necessary to analyze the characteristics of the greatest common factor frequency and the least common multiple period universally existing in periodic signals. The regulation of the quantitative phase shift resolution between periodic signals is presented.The cause of difference in phase characteristics between periodic signals is explained well. In this paper we propose different application prospects based on the regular phenomenon between periodic signals, with focusing on the methods for high precision frequency measurement and transient stability measurement. The experimental results are satisfactory.