A quasi-optical dielectric lens used for W-band focal plane array passive imaging has been developed. The imaging system requires the lens to form beam spot with 3 dB width less than 35 mm at distance of 3500 mm. The ...A quasi-optical dielectric lens used for W-band focal plane array passive imaging has been developed. The imaging system requires the lens to form beam spot with 3 dB width less than 35 mm at distance of 3500 mm. The powerful optical design software ZEMAX was utilized to design the contours of the lens, and numerical method based on ray tracing and Huygens’ Principle was processed to verify the design result. Measurement result shows that the 3 dB width of the beam spot formed by the lens is 34 mm at distance of 3460 mm, and the beam pattern on imaging plane are equally arranged and the intensity decreases only 0.55 dB while the object lateral deviation increases to 300 mm.展开更多
This paper designs a 3 mm radiometer and validate with experiments based on the principle of passive millimeter wave (PMMW) imaging. The poor spatial resolution, which is limited by antenna size, should be improved ...This paper designs a 3 mm radiometer and validate with experiments based on the principle of passive millimeter wave (PMMW) imaging. The poor spatial resolution, which is limited by antenna size, should be improved by post data processing. A conjugate-gradient (CG) algorithm is adopted to circumvent this drawback. Simulation and real data collected in laboratory environment are given, and the results show that the CG algorithm improves the spatial resolution and convergent rate. Further, it can reduce the ringing effects which are caused by regularizing the image restoration. Thus, the CG algorithm is easily implemented for PMMW imaging.展开更多
文摘针对近程焦平面被动阵成像系统应用,设计了3 mm波准光介质透镜天线。根据应用需求设计成像系统光路结构,并结合高斯准光理论得出光路设计参数;选择透镜表面为双凸非球面结构,利用光学分析软件ZEMAX优化设计透镜轮廓以减小成像像差;利用电磁仿真软件FEKO计算透镜天线近场分布,对设计进行验证与修正。测试结果表明,所设计的介质透镜在像平面上形成的聚焦波束3 d B尺寸仅为29.5 mm,偏轴时波束指向均匀性好,在700 mm(H)*1 800 mm(V)视场范围内波束功率电平值性改变量小于0.9 d B。
文摘A quasi-optical dielectric lens used for W-band focal plane array passive imaging has been developed. The imaging system requires the lens to form beam spot with 3 dB width less than 35 mm at distance of 3500 mm. The powerful optical design software ZEMAX was utilized to design the contours of the lens, and numerical method based on ray tracing and Huygens’ Principle was processed to verify the design result. Measurement result shows that the 3 dB width of the beam spot formed by the lens is 34 mm at distance of 3460 mm, and the beam pattern on imaging plane are equally arranged and the intensity decreases only 0.55 dB while the object lateral deviation increases to 300 mm.
基金supported partly by the State Key Program of National Natural Science Foundation of China(60632020)the Youth Science Foundation of University of Electronic Science and Technology of China(JX0823).
文摘This paper designs a 3 mm radiometer and validate with experiments based on the principle of passive millimeter wave (PMMW) imaging. The poor spatial resolution, which is limited by antenna size, should be improved by post data processing. A conjugate-gradient (CG) algorithm is adopted to circumvent this drawback. Simulation and real data collected in laboratory environment are given, and the results show that the CG algorithm improves the spatial resolution and convergent rate. Further, it can reduce the ringing effects which are caused by regularizing the image restoration. Thus, the CG algorithm is easily implemented for PMMW imaging.