期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
OSEM重建算法中几个关键问题的研究 被引量:2
1
作者 凌松云 曹文田 包尚联 《中国医学物理学杂志》 CSCD 2008年第4期729-736,共8页
目的:改进平行孔准直器SPECT系统的成像方法,快速、精确地实现有序子集期望值最大化(OSEM)重建算法。方法:采用理想平行孔和张角效应平行孔准直器两种模型,将准直器的空间响应融入系统传输矩阵,利用改进的射线跟踪算法进行衰减校正。结... 目的:改进平行孔准直器SPECT系统的成像方法,快速、精确地实现有序子集期望值最大化(OSEM)重建算法。方法:采用理想平行孔和张角效应平行孔准直器两种模型,将准直器的空间响应融入系统传输矩阵,利用改进的射线跟踪算法进行衰减校正。结果:随着准直器张角的增加,Jaszczak模型的重建图像在边界出现明显的亮环;利用考虑准直器空间响应的系统矩阵进行图像重建,能较好的抑制边界伪影。结论:融入准直器空间响应函数的系统矩阵更为精确、贴近真实情况,能较好的抑制边界伪影,提高了重建图像的对比度和信噪比。 展开更多
关键词 OSEM 平行孔准直器 张角效应 准直器空间响应函数 边界伪影
下载PDF
A compact gamma camera with scintillation array and parallel-hole collimator 被引量:1
2
作者 ZHU Jie MA Hongguang +3 位作者 MA Wenyan ZENG Hui WANG Zhaomin XU Zizhong 《Nuclear Science and Techniques》 SCIE CAS CSCD 2008年第5期297-301,共5页
A new compact gamma camera for small object imaging has been developed.It consists of a pixelized Nal(T1) scintillator array coupled to a position sensitive photomultiplier tube (Hamamatsu R2486) with a parallel-hole ... A new compact gamma camera for small object imaging has been developed.It consists of a pixelized Nal(T1) scintillator array coupled to a position sensitive photomultiplier tube (Hamamatsu R2486) with a parallel-hole lead collimator.The compact camera has better spatial resolution than Anger camera.The average value of intrinsic spatial resolutions is 2.3 mm (FWHM).The overall spatial resolution (FWHM) is 3,5 and 6 mm at 0,2.5 and 3 mm SCD (source-to-collimator distance),respectively.The phantom studies with the compact camera have demonstrated that parallel-hole collimator gamma camera is a practical technique for nuclear medicine application. 展开更多
关键词 核医学 肿瘤诊断 γ照相机 并行孔准直仪
下载PDF
Performance evaluation of a parallel-hole collimated detector module for animal SPECT imaging 被引量:1
3
作者 黄先超 章志明 +10 位作者 李道武 唐浩辉 李婷 廖燕飞 刘军辉 王培林 陈研 王英杰 魏龙 单保慈 王宝义 《Chinese Physics C》 SCIE CAS CSCD 2011年第12期1162-1165,共4页
We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with ... We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with an effective area of 80 mm× 80 mm. The detector is composed of a NaI scintillation crystal array coupled to four H8500 position sensitive photomultiplier tubes (PS-PMT). The intrinsic energy resolution of the detector is 11.5% at 140 keV on average. The planar spatial resolution of the module changes from 2.2 mm to 5.1 mm at different source-to-collimator distances with an unchanged sensitivity of about 34cps/MBq. Additionally, the SPECT Micro Deluxe Phantom imaging was performed with a radius of rotation (ROR) of 40 mm. Using the FBP reconstruction algorithm, a high performance image was obtained, indicating the feasibility of this detector module. 展开更多
关键词 animal imaging SPECT parallel-hole collimator
原文传递
Fanbeam准直器与平行孔准直器的性能比较
4
作者 秦卫仕 周绿漪 《华西医科大学学报》 CSCD 北大核心 2002年第4期648-649,668,共3页
目的 比较两种准直器的能峰响应、探测灵敏度、计数随采集窗宽变化的响应、计数随探测距离变化的响应等特性 ,评估 Fanbeam准直器性能特点 ,为临床更好地应用 Fanbeam准直器提供参考。方法 制作一个活度为 1.85× 10 8Bq(5 m Ci)... 目的 比较两种准直器的能峰响应、探测灵敏度、计数随采集窗宽变化的响应、计数随探测距离变化的响应等特性 ,评估 Fanbeam准直器性能特点 ,为临床更好地应用 Fanbeam准直器提供参考。方法 制作一个活度为 1.85× 10 8Bq(5 m Ci)的 99m Tc点源 ,分别用 Fanbeam准直器和平行孔准直器进行能峰检测、探测灵敏度检测、计数随采集窗宽变化和随探测距离变化的检测。结果 两种准直器的能谱响应无差异 ,与系统的固有能量响应曲线相一致。Fanbeam准直器的探测灵敏度高于平行孔准直器 ,最小探测距离条件下 ,灵敏度提高 10 0 %。采集计数随窗宽变化的响应特性 ,两种准直器相一致。配置平行孔准直器 (HPC- 4 5 ) ,计数随探测距离的变化不明显 ;配置Fanbeam准直器 (HU FB- 75 ) ,探测距离在 0~ 34cm的范围内 ,计数随探测距离的增加而增加 ,34cm处计数最大 ,探测距离大于 34cm ,计数随探测距离的增加而减少。结论 应用 Fanbeam准直器 ,系统的能量分辨率不受影响。Fanbeam准直器的探测灵敏度是平行孔准直器的 2倍以上。应用 Fanbeam准直器 ,其适宜的采集窗宽为 10 %~30 %。 Fanbeam准直器有一个特有的探测聚焦线 (Focal line) ,本文实测 HU FB- 75准直器的焦距为 34cm。 展开更多
关键词 Fanbeam准直器 平行孔准直器 比较
下载PDF