Single photon counting imaging technology has been widely used in space environment detection, astronomy observation, nuclear physics, and ultraweak bioluminescence. However, the distortion of the single photon counti...Single photon counting imaging technology has been widely used in space environment detection, astronomy observation, nuclear physics, and ultraweak bioluminescence. However, the distortion of the single photon counting image will badly affect the measurement results. Therefore, the correction of distortion for single photon counting image is very significant. Ultraviolet single photon imaging system with wedge and strip anode is introduced and the influence factor leading to image distortion is analyzed. To correct original distorted image, three different image correction methods, namely, the physical correction, the global correction, and the local correction, are applied. In addition, two parameters, i.e., the position index and the linearity index, are defined to evaluate the performance of the three methods. The results suggest that the correction methods can improve the quality of the initial image without losing gray information of each counting light spot. And the local correction can provide the best visual inspections and performance evaluation among the three methods.展开更多
In this paper, the fabrication and testing results of a two-dimensional pin-cushion position sensitive detector (PSD) are presented. The obtained pin-cushion PSD with an 8×8 mm2 effective area presents a maximum ...In this paper, the fabrication and testing results of a two-dimensional pin-cushion position sensitive detector (PSD) are presented. The obtained pin-cushion PSD with an 8×8 mm2 effective area presents a maximum spectral response of 0.5 mA/mW at 850-nm wavelength, a 12-nA dark current at 5-V reverse voltage, a reverse breakdown voltage of 50 V, a nonlinearity of 2.175%, and a spatial resolution of 10 μm. The spatial resolution is relatively low and the slight pin-cushion concave distortion is generated due to the incompletely satisfied relationship between sheet resistivity of the anode and the resistance per unit length.展开更多
基金supported by the Knowledge Innovation Program of Chinese Academy of Sciences.
文摘Single photon counting imaging technology has been widely used in space environment detection, astronomy observation, nuclear physics, and ultraweak bioluminescence. However, the distortion of the single photon counting image will badly affect the measurement results. Therefore, the correction of distortion for single photon counting image is very significant. Ultraviolet single photon imaging system with wedge and strip anode is introduced and the influence factor leading to image distortion is analyzed. To correct original distorted image, three different image correction methods, namely, the physical correction, the global correction, and the local correction, are applied. In addition, two parameters, i.e., the position index and the linearity index, are defined to evaluate the performance of the three methods. The results suggest that the correction methods can improve the quality of the initial image without losing gray information of each counting light spot. And the local correction can provide the best visual inspections and performance evaluation among the three methods.
文摘In this paper, the fabrication and testing results of a two-dimensional pin-cushion position sensitive detector (PSD) are presented. The obtained pin-cushion PSD with an 8×8 mm2 effective area presents a maximum spectral response of 0.5 mA/mW at 850-nm wavelength, a 12-nA dark current at 5-V reverse voltage, a reverse breakdown voltage of 50 V, a nonlinearity of 2.175%, and a spatial resolution of 10 μm. The spatial resolution is relatively low and the slight pin-cushion concave distortion is generated due to the incompletely satisfied relationship between sheet resistivity of the anode and the resistance per unit length.