Dedicated experiments are designed to collect the infrared spectra of dissolved gas-in-oil of power transformers. Spectra of diagnostic gases are collected by 3 different laboratorial FTIR spectrometers using 3 differ...Dedicated experiments are designed to collect the infrared spectra of dissolved gas-in-oil of power transformers. Spectra of diagnostic gases are collected by 3 different laboratorial FTIR spectrometers using 3 different gas cells with various sets of equipment parameters. A formula is deduced to calculate the shortest optical length to detect a specific concentration according to measurements on gases with known concentrations near to the minimum detection limit. Collected spectra and calculated results suggested that the optimum optical length of the gas cell should be 150 mm to realize on-line monitoring of diagnostic gases within the required concentration range. At the end, an economic novel design of the gas cell is proposed based on the optimum length.展开更多
An optical length measuring system base on all-fiber optic interferometer is proposed. The theoretical analysis indicates that, when the two branches of the interferometer are equal, the output have the maximum cohere...An optical length measuring system base on all-fiber optic interferometer is proposed. The theoretical analysis indicates that, when the two branches of the interferometer are equal, the output have the maximum coherent intensity. Therefore, the optical length can be obtained by measuring the distance of collimator movement. Through the experiment and simulation, the impact of the signal-to-noise ratio and fluctuation of the coupling efficiency on null error has been obtained.展开更多
文摘Dedicated experiments are designed to collect the infrared spectra of dissolved gas-in-oil of power transformers. Spectra of diagnostic gases are collected by 3 different laboratorial FTIR spectrometers using 3 different gas cells with various sets of equipment parameters. A formula is deduced to calculate the shortest optical length to detect a specific concentration according to measurements on gases with known concentrations near to the minimum detection limit. Collected spectra and calculated results suggested that the optimum optical length of the gas cell should be 150 mm to realize on-line monitoring of diagnostic gases within the required concentration range. At the end, an economic novel design of the gas cell is proposed based on the optimum length.
基金supported by the Fundamental Research Funds for the Central Universities under Grant No.E022050205
文摘An optical length measuring system base on all-fiber optic interferometer is proposed. The theoretical analysis indicates that, when the two branches of the interferometer are equal, the output have the maximum coherent intensity. Therefore, the optical length can be obtained by measuring the distance of collimator movement. Through the experiment and simulation, the impact of the signal-to-noise ratio and fluctuation of the coupling efficiency on null error has been obtained.