This study used a three-dimensional numerical model of a proton exchange membrane fuel cell with five types of channels:a smooth channel(Case 1);eight rectangular baffles were arranged in the upstream(Case 2),midstrea...This study used a three-dimensional numerical model of a proton exchange membrane fuel cell with five types of channels:a smooth channel(Case 1);eight rectangular baffles were arranged in the upstream(Case 2),midstream(Case 3),downstream(Case 4),and the entire cathode flow channel(Case 5)to study the effects of baffle position on mass transport,power density,net power,etc.Moreover,the effects of back pressure and humidity on the voltage were investigated.Results showed that compared to smooth channels,the oxygen and water transport facilitation at the diffusion layer-channel interface were added 11.53%-20.60%and 7.81%-9.80%at 1.68 A·cm^(-2)by adding baffles.The closer the baffles were to upstream,the higher the total oxygen flux,but the lower the flux uniformity the worse the water removal.The oxygen flux of upstream baffles was 8.14%higher than that of downstream baffles,but oxygen flux uniformity decreased by 18.96%at 1.68 A·cm^(-2).The order of water removal and voltage improvement was Case 4>Case 5>Case 3>Case 2>Case 1.Net power of Case 4 was 9.87%higher than that of the smooth channel.To the Case 4,when the cell worked under low back pressure or high humidity,the voltage increments were higher.The potential increment for the back pressure of 0 atm was 0.9%higher than that of 2 atm(1 atm=101.325 kPa).The potential increment for the humidity of 100%was 7.89%higher than that of 50%.展开更多
In order to diagnose the working status of each module on sensor node and make sure the wireless sensor networks (WSN) work properly, the components of sensor node and their working characteristics are studied. An o...In order to diagnose the working status of each module on sensor node and make sure the wireless sensor networks (WSN) work properly, the components of sensor node and their working characteristics are studied. An on-line fault self-diagnosis method for sensor node is proposed. First, a flexible fault sensing circuit is designed as a state detection module on sensor node. Second, a self- diagnosis algorithm is proposed based on the hardware design and the failure analysis on sensor node. Finally, in order to ensure the WSN reliability, the voltage changes of each module working statuses can be observed using the state detection module and the faulty module will be found out timely. The experimental results show that this self-diagnosis method is suitable to sensor nodes in WSN.展开更多
基金financially supported by the Science&Technology Project of Beijing Education Committee(KM202210005013)National Natural Science Foundation of China(52306180)。
文摘This study used a three-dimensional numerical model of a proton exchange membrane fuel cell with five types of channels:a smooth channel(Case 1);eight rectangular baffles were arranged in the upstream(Case 2),midstream(Case 3),downstream(Case 4),and the entire cathode flow channel(Case 5)to study the effects of baffle position on mass transport,power density,net power,etc.Moreover,the effects of back pressure and humidity on the voltage were investigated.Results showed that compared to smooth channels,the oxygen and water transport facilitation at the diffusion layer-channel interface were added 11.53%-20.60%and 7.81%-9.80%at 1.68 A·cm^(-2)by adding baffles.The closer the baffles were to upstream,the higher the total oxygen flux,but the lower the flux uniformity the worse the water removal.The oxygen flux of upstream baffles was 8.14%higher than that of downstream baffles,but oxygen flux uniformity decreased by 18.96%at 1.68 A·cm^(-2).The order of water removal and voltage improvement was Case 4>Case 5>Case 3>Case 2>Case 1.Net power of Case 4 was 9.87%higher than that of the smooth channel.To the Case 4,when the cell worked under low back pressure or high humidity,the voltage increments were higher.The potential increment for the back pressure of 0 atm was 0.9%higher than that of 2 atm(1 atm=101.325 kPa).The potential increment for the humidity of 100%was 7.89%higher than that of 50%.
基金Supported by the Basic Research Foundation of Beijing Institute of Technology(200705422009)
文摘In order to diagnose the working status of each module on sensor node and make sure the wireless sensor networks (WSN) work properly, the components of sensor node and their working characteristics are studied. An on-line fault self-diagnosis method for sensor node is proposed. First, a flexible fault sensing circuit is designed as a state detection module on sensor node. Second, a self- diagnosis algorithm is proposed based on the hardware design and the failure analysis on sensor node. Finally, in order to ensure the WSN reliability, the voltage changes of each module working statuses can be observed using the state detection module and the faulty module will be found out timely. The experimental results show that this self-diagnosis method is suitable to sensor nodes in WSN.