A simple solution for a multilayer metallic optical waveguide by transforming it intoan equivalent three-layer slab waveguide is presented. The dispersion relation of the equivalentthree-layer slab waveguide is solved...A simple solution for a multilayer metallic optical waveguide by transforming it intoan equivalent three-layer slab waveguide is presented. The dispersion relation of the equivalentthree-layer slab waveguide is solved by using a simple iterative formula. This method itself isexact and can approach any accuracy desired. Moreover, the numerical results for four-layer andfive-layer structures show that the second-order solution is also accurate enough. It is simple andhas the same form of expressions for TE and TM modes and for different layer structures.展开更多
A metal-clad planar polymer waveguide refractive index sensor based on epoxy(EPO)polymer materials by using light intensity interrogation at 850 nm is designed.The polymethyl methacrylate(PMMA)material is deployed as ...A metal-clad planar polymer waveguide refractive index sensor based on epoxy(EPO)polymer materials by using light intensity interrogation at 850 nm is designed.The polymethyl methacrylate(PMMA)material is deployed as the low refractive index(RI)buffer layer in order to better couple the optical guided mode and the surface plasmon polaritons(SPP)mode for working in water environment.The effects of the gold film thickness,PMMA buffer layer thickness,waveguide layer thickness,waveguide width,and gold length on the sensor sensing characteristics have been comprehensively studied.Simulation results demonstrate that the normalized transmission increases quasi-linearly with the increment of RI of the analyte from 1.33 to 1.46.The sensitivity is 491.5 dB/RIU,corresponding to a high RI resolution of 2.6×10^(9)RIU.The designed SPP-based optical waveguide sensor is low-cost,wide-range,and high-precision,and has a broad application prospect in biochemical sensing with merits of miniaturization,flexibility,and multiplexing.展开更多
文摘A simple solution for a multilayer metallic optical waveguide by transforming it intoan equivalent three-layer slab waveguide is presented. The dispersion relation of the equivalentthree-layer slab waveguide is solved by using a simple iterative formula. This method itself isexact and can approach any accuracy desired. Moreover, the numerical results for four-layer andfive-layer structures show that the second-order solution is also accurate enough. It is simple andhas the same form of expressions for TE and TM modes and for different layer structures.
基金The authors gratefully acknowledge the financial support from the Shandong Provincial Key Research and Development Program(Grant Nos.2018YFJH0702 and 2019JZZY020711)Shandong Postdoctoral Innovation Project,and Qingdao Postdoctoral Applied Research Project.
文摘A metal-clad planar polymer waveguide refractive index sensor based on epoxy(EPO)polymer materials by using light intensity interrogation at 850 nm is designed.The polymethyl methacrylate(PMMA)material is deployed as the low refractive index(RI)buffer layer in order to better couple the optical guided mode and the surface plasmon polaritons(SPP)mode for working in water environment.The effects of the gold film thickness,PMMA buffer layer thickness,waveguide layer thickness,waveguide width,and gold length on the sensor sensing characteristics have been comprehensively studied.Simulation results demonstrate that the normalized transmission increases quasi-linearly with the increment of RI of the analyte from 1.33 to 1.46.The sensitivity is 491.5 dB/RIU,corresponding to a high RI resolution of 2.6×10^(9)RIU.The designed SPP-based optical waveguide sensor is low-cost,wide-range,and high-precision,and has a broad application prospect in biochemical sensing with merits of miniaturization,flexibility,and multiplexing.