Image compression techniques aim to reduce redundant information in order to allow data storage and transmission in an efficient way. In this work, we propose and analyze a lossy image compression method based on the ...Image compression techniques aim to reduce redundant information in order to allow data storage and transmission in an efficient way. In this work, we propose and analyze a lossy image compression method based on the singular value decomposition using an optimal choice of eigenvalues and an adaptive mechanism for block partitioning. Experiments are conducted on several images to demonstrate the effectiveness of the proposed compression method in comparison with the direct application of the singular value decomposition.展开更多
Array of Things (AoT)通过单一位置上的多传感器对城市系统进行连续动态观测。AoT观测数据量大且持续增长,使得如何利用有限的计算资源进行AoT序列数据的压缩传输成为其应用的关键瓶颈之一。本文提出了一种基于张量分解的AoT序列数据...Array of Things (AoT)通过单一位置上的多传感器对城市系统进行连续动态观测。AoT观测数据量大且持续增长,使得如何利用有限的计算资源进行AoT序列数据的压缩传输成为其应用的关键瓶颈之一。本文提出了一种基于张量分解的AoT序列数据的有损压缩方法。面向其海量、高维且需在传感器端处理的需求,该方法首先将AoT序列数据组织成高维张量,利用算法复杂度较低的张量CANDECOMP/PARAFAC (CP)分解提取各维度上的特征主分量,而后利用张量重构实现特征保持的数据有损压缩。利用基于张量分解的有损压缩方法,针对美国芝加哥市区的24 h内感测的声光电磁数据进行了实验,讨论了不同压缩参数对压缩比、压缩误差、压缩精度、压缩时间、压缩过程运行内存占用和压缩结果内存占用之间的影响。实验结果表明该方法可实现AoT序列数据的有损压缩,其较小的内存占用能够支持传感器端数据压缩。并且与原始光场强度对比表明,压缩后的数据保持了原有时空分布特征。与传统矢量量化编码压缩方法相比,在相同压缩精度下,本文方法的压缩比约高27%~76%,压缩时间约节省46%~73%,压缩结果所占内存约节省17%~57%,因此本文方法具有更高的压缩比,更低的压缩时间和内存占用,可为Ao T这一类数据的大规模有损压缩提供借鉴意义。展开更多
In this paper, we introduce a novel approach to compress jointly a medical image and a multichannel bio-signals (e.g. ECG, EEG). This technique is based on the idea of Multimodal Compression (MC) which requires only o...In this paper, we introduce a novel approach to compress jointly a medical image and a multichannel bio-signals (e.g. ECG, EEG). This technique is based on the idea of Multimodal Compression (MC) which requires only one codec instead of multiple codecs. Objectively, biosignal samples are merged in the spatial domain of the image using a specific mixing function. Afterwards, the whole mixture is compressed using JPEG 2000. The spatial mixing function inserts samples in low-frequency regions, defined using a set of operations, including down-sampling, interpolation, and quad-tree decomposition. The decoding is achieved by inverting the process using a separation function. Results show that this technique allows better performances in terms of Compression Ratio (CR) compared to approaches which encode separately modalities. The reconstruction quality is evaluated on a set of test data using the PSNR (Peak Signal Noise Ratio) and the PRD (Percent Root Mean Square Difference), respectively for the image and biosignals.展开更多
文摘Image compression techniques aim to reduce redundant information in order to allow data storage and transmission in an efficient way. In this work, we propose and analyze a lossy image compression method based on the singular value decomposition using an optimal choice of eigenvalues and an adaptive mechanism for block partitioning. Experiments are conducted on several images to demonstrate the effectiveness of the proposed compression method in comparison with the direct application of the singular value decomposition.
文摘Array of Things (AoT)通过单一位置上的多传感器对城市系统进行连续动态观测。AoT观测数据量大且持续增长,使得如何利用有限的计算资源进行AoT序列数据的压缩传输成为其应用的关键瓶颈之一。本文提出了一种基于张量分解的AoT序列数据的有损压缩方法。面向其海量、高维且需在传感器端处理的需求,该方法首先将AoT序列数据组织成高维张量,利用算法复杂度较低的张量CANDECOMP/PARAFAC (CP)分解提取各维度上的特征主分量,而后利用张量重构实现特征保持的数据有损压缩。利用基于张量分解的有损压缩方法,针对美国芝加哥市区的24 h内感测的声光电磁数据进行了实验,讨论了不同压缩参数对压缩比、压缩误差、压缩精度、压缩时间、压缩过程运行内存占用和压缩结果内存占用之间的影响。实验结果表明该方法可实现AoT序列数据的有损压缩,其较小的内存占用能够支持传感器端数据压缩。并且与原始光场强度对比表明,压缩后的数据保持了原有时空分布特征。与传统矢量量化编码压缩方法相比,在相同压缩精度下,本文方法的压缩比约高27%~76%,压缩时间约节省46%~73%,压缩结果所占内存约节省17%~57%,因此本文方法具有更高的压缩比,更低的压缩时间和内存占用,可为Ao T这一类数据的大规模有损压缩提供借鉴意义。
文摘In this paper, we introduce a novel approach to compress jointly a medical image and a multichannel bio-signals (e.g. ECG, EEG). This technique is based on the idea of Multimodal Compression (MC) which requires only one codec instead of multiple codecs. Objectively, biosignal samples are merged in the spatial domain of the image using a specific mixing function. Afterwards, the whole mixture is compressed using JPEG 2000. The spatial mixing function inserts samples in low-frequency regions, defined using a set of operations, including down-sampling, interpolation, and quad-tree decomposition. The decoding is achieved by inverting the process using a separation function. Results show that this technique allows better performances in terms of Compression Ratio (CR) compared to approaches which encode separately modalities. The reconstruction quality is evaluated on a set of test data using the PSNR (Peak Signal Noise Ratio) and the PRD (Percent Root Mean Square Difference), respectively for the image and biosignals.