A numerical program is built to simulate the performance of a spark ignited two-stroke free-piston engine coupled with a linear generator. The computational model combines a series of dynamic and thermodynamic equatio...A numerical program is built to simulate the performance of a spark ignited two-stroke free-piston engine coupled with a linear generator. The computational model combines a series of dynamic and thermodynamic equations that are solved simultaneously to predict the performances of the engines. The dynamic analysis performed consists of an evaluation of the frictional force and load force introduced by the generator. The thermodynamic analysis used a single zone model to describe the engine' s working cycle which includes intake, scavenging, compression, combustion and expansion, and to evaluate the effect of heat transfer based on the first law of thermodynamics and the ideal gas state equation. Because there is no crankshaft, a time based Wiebe equation was used to express the fraction of fuel burned in the combustion. The calculated results were validated by using the experimental data from another research group. The results indicate that the free-piston generator has some advantages over conventional engines.展开更多
Alternate path(AP) method is the most widely used method for the progressive collapse analysis,and its application in frame structures has been well proved.However,the application of AP method for other structures,esp...Alternate path(AP) method is the most widely used method for the progressive collapse analysis,and its application in frame structures has been well proved.However,the application of AP method for other structures,especially for cable-stayed structures,should be further developed.The four analytical procedures,i.e.,linear static,nonlinear static,linear dynamic,and nonlinear dynamic were firstly improved by taking into account the initial state.Then a cable-stayed structure was studied using the four improved methods.Furthermore,the losses of both one cable and two cables were discussed.The results show that for static and dynamic analyses of the cable-stayed bridges,there is large difference between the results obtained from simulations starting with either a deformed or a nondeformed configuration at the time of cable loss.The static results are conservative in the vicinity of the ruptured cable,but the dynamic effect of the cable loss in the area farther away from the loss-cable cannot be considered.Moreover,the dynamic amplification factor of 2.0 is found to be a good estimate for static analysis procedures,since linear static and linear dynamic procedures yield approximately the same maximum vertical deflection.The results of the comprehensive evaluation of the cable failure show that the tread of the progressive failure of the cable-stayed bridges decreases when the location of the failed cables is closer to the pylon.展开更多
Dynamic characteristic is presented by identifying the model and the dynamic parameters of a precise long stroke linear motor (PLSLM) with the air-bearing in optical lithography. The PLSLM is supported by air-bearin...Dynamic characteristic is presented by identifying the model and the dynamic parameters of a precise long stroke linear motor (PLSLM) with the air-bearing in optical lithography. The PLSLM is supported by air-bearing on the stator, and is driven by on-board two large linear motors in a cross-configuration. Firstly, a model of the PLSLM is established by finite element method (FEM). Secondly, based on the model, the natural frequencies and model shapes are discusse& And the contribution of each active mode is evaluated by computing the modal participation factors (MPF), which indicates the major vibration direction. Furthermore, by the experimental modal analysis, the experimental results are in agreement with simulation results, which it is sure that the FEM is reasonable. What's more, comparing with the effects on the frequency due to the air-bearing stiffness, the relations of the natural frequencies with the air-bearing stiffness are found. It is found that the frequency response curve is fluctuant with the air-bearing stiffness in each direction. Finally, it is conclusion that the natural frequency of the PLSLM is largely affected by the air-bearing stiffness variety. This research is contributed to the dynamic characteristics resulted from the air-beating stiffness. Further work will include better optimization on the dynamic parameter in the controller design through the control algorithm for the precise long stroke motor.展开更多
文摘A numerical program is built to simulate the performance of a spark ignited two-stroke free-piston engine coupled with a linear generator. The computational model combines a series of dynamic and thermodynamic equations that are solved simultaneously to predict the performances of the engines. The dynamic analysis performed consists of an evaluation of the frictional force and load force introduced by the generator. The thermodynamic analysis used a single zone model to describe the engine' s working cycle which includes intake, scavenging, compression, combustion and expansion, and to evaluate the effect of heat transfer based on the first law of thermodynamics and the ideal gas state equation. Because there is no crankshaft, a time based Wiebe equation was used to express the fraction of fuel burned in the combustion. The calculated results were validated by using the experimental data from another research group. The results indicate that the free-piston generator has some advantages over conventional engines.
基金supported by the National Natural Science Foundation of China(No. 50478075)the Jiangsu "Six Top Talent" Program of China(No. 07-F-008)+1 种基金the Priority Academic Program Development of Jiangsu Higher Education Institutionsthe Scientific Research Foundation of Graduate School of Southeast University (No. YBJJ0817),China
文摘Alternate path(AP) method is the most widely used method for the progressive collapse analysis,and its application in frame structures has been well proved.However,the application of AP method for other structures,especially for cable-stayed structures,should be further developed.The four analytical procedures,i.e.,linear static,nonlinear static,linear dynamic,and nonlinear dynamic were firstly improved by taking into account the initial state.Then a cable-stayed structure was studied using the four improved methods.Furthermore,the losses of both one cable and two cables were discussed.The results show that for static and dynamic analyses of the cable-stayed bridges,there is large difference between the results obtained from simulations starting with either a deformed or a nondeformed configuration at the time of cable loss.The static results are conservative in the vicinity of the ruptured cable,but the dynamic effect of the cable loss in the area farther away from the loss-cable cannot be considered.Moreover,the dynamic amplification factor of 2.0 is found to be a good estimate for static analysis procedures,since linear static and linear dynamic procedures yield approximately the same maximum vertical deflection.The results of the comprehensive evaluation of the cable failure show that the tread of the progressive failure of the cable-stayed bridges decreases when the location of the failed cables is closer to the pylon.
基金National Basic Research Program of China (973 Program,No.2003CB716206)National Natural Science Foundation of China (No.50605025)
文摘Dynamic characteristic is presented by identifying the model and the dynamic parameters of a precise long stroke linear motor (PLSLM) with the air-bearing in optical lithography. The PLSLM is supported by air-bearing on the stator, and is driven by on-board two large linear motors in a cross-configuration. Firstly, a model of the PLSLM is established by finite element method (FEM). Secondly, based on the model, the natural frequencies and model shapes are discusse& And the contribution of each active mode is evaluated by computing the modal participation factors (MPF), which indicates the major vibration direction. Furthermore, by the experimental modal analysis, the experimental results are in agreement with simulation results, which it is sure that the FEM is reasonable. What's more, comparing with the effects on the frequency due to the air-bearing stiffness, the relations of the natural frequencies with the air-bearing stiffness are found. It is found that the frequency response curve is fluctuant with the air-bearing stiffness in each direction. Finally, it is conclusion that the natural frequency of the PLSLM is largely affected by the air-bearing stiffness variety. This research is contributed to the dynamic characteristics resulted from the air-beating stiffness. Further work will include better optimization on the dynamic parameter in the controller design through the control algorithm for the precise long stroke motor.