The anti-overturning ability and structure safety of jack-up unit in in-place condition are often affected by environment loads, especially wind load. According to the MODU rule, the projected area method is used for ...The anti-overturning ability and structure safety of jack-up unit in in-place condition are often affected by environment loads, especially wind load. According to the MODU rule, the projected area method is used for calculating the wind load. However, the calculated results are conservative and not good for structure optimization design. In this paper, a 400 ft jack-up is studied as an example. Based on the wind tunnel test and numerical simulation method, some key points of wind load calculation, such as shielding effect, lift effect and shape coefficient of component, are discussed. The study shows that the points mentioned above, which are ignored in the MODU rule calculation, result in the conservative result.展开更多
A slat without a cove is built on the basis of a bionic airfoil (i.e. stowed multi-element airfoil), which is extracted from a long-eared owl wing. The three-dimensional models with a deployed slat and a stowed slat...A slat without a cove is built on the basis of a bionic airfoil (i.e. stowed multi-element airfoil), which is extracted from a long-eared owl wing. The three-dimensional models with a deployed slat and a stowed slat are measured in a low-turbulence wind tunnel. The results are used to characterize high-lift effect: compared with the stowed slat, the deployed slat works more like a spoiler at low angles of attack, but like a conventional slat or slot at high angles of attack. In addition, it can also increase stall angle and maximum lift coefficient, and postpone the decrease in the gradient of the lift coefficient. At the same time, the flow field visualized around both three-dimensional models suggests the leading-edge separation associated with the decrease in the gradient of the lift coefficient, Furthermore, the related two-dimensional simulation well agrees with the analysis of the lift coefficient, as the complement to the experiment. The bionic slat may be used as reference in the design of leading-edge slats without a cove.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.51079034)the Fundamental Research Funds for the Central Universities(Grant No.HEUCFR1003)
文摘The anti-overturning ability and structure safety of jack-up unit in in-place condition are often affected by environment loads, especially wind load. According to the MODU rule, the projected area method is used for calculating the wind load. However, the calculated results are conservative and not good for structure optimization design. In this paper, a 400 ft jack-up is studied as an example. Based on the wind tunnel test and numerical simulation method, some key points of wind load calculation, such as shielding effect, lift effect and shape coefficient of component, are discussed. The study shows that the points mentioned above, which are ignored in the MODU rule calculation, result in the conservative result.
文摘A slat without a cove is built on the basis of a bionic airfoil (i.e. stowed multi-element airfoil), which is extracted from a long-eared owl wing. The three-dimensional models with a deployed slat and a stowed slat are measured in a low-turbulence wind tunnel. The results are used to characterize high-lift effect: compared with the stowed slat, the deployed slat works more like a spoiler at low angles of attack, but like a conventional slat or slot at high angles of attack. In addition, it can also increase stall angle and maximum lift coefficient, and postpone the decrease in the gradient of the lift coefficient. At the same time, the flow field visualized around both three-dimensional models suggests the leading-edge separation associated with the decrease in the gradient of the lift coefficient, Furthermore, the related two-dimensional simulation well agrees with the analysis of the lift coefficient, as the complement to the experiment. The bionic slat may be used as reference in the design of leading-edge slats without a cove.