During operating of the X-ray machines, if the protection of X-ray rooms is insufficient, not only the patient but also clinical staffs as well as public are exposed to high X-ray dosage and they are affected from X-r...During operating of the X-ray machines, if the protection of X-ray rooms is insufficient, not only the patient but also clinical staffs as well as public are exposed to high X-ray dosage and they are affected from X-ray related to the dose level. In the present survey, by testing the radiological leakage and scatter from X-rays machines in radiology departments of 7 randomly selected hospitals in Duhok governorate, the effects dose of X-ray to the both control panel area and the patients waiting or visiting area who are located near the radiography room, were measured. The dose was recorded for a range of peak kilovoltage (kVp) and mAs values to find efficiency of shielding materials (barriers) of radiography rooms for different X-rays level. The measurements were performed at one meter above the ground surface which was the same height of X-rays tube by using Gamma Scout dosimeter. From the measurement results, it was seen that the most hospitals barriers (doors and walls) were not appropriate to the standards except 2 hospitals. The maximum effective doses were measured in uncontrolled area of Khazer hospital which was 82.48 ± 0.73 mSv·yr-1 that was much more than the reference dose limits and in controlled area of Haval Banda Zaroka hospital which was 12.98 ± 0.16 mSv·yr-1. In result, the knowledge about the radiation dose affecting the radiologists and public in the selected hospitals was obtained, and by informing the radiologists and the hospitals managements, the necessary regulations would be planned.展开更多
During the operation of an X-ray machine, if the radiation protection of X-ray room is insufficient, not only the patient but also clinical staffs as well as public are exposed to high X-ray exposures. In this researc...During the operation of an X-ray machine, if the radiation protection of X-ray room is insufficient, not only the patient but also clinical staffs as well as public are exposed to high X-ray exposures. In this research work, leakage and scattered radiations were measured from X-ray machine in the radiology department of Cape Coast Teaching hospital in the Cape Coast Municipality of Ghana. The scattered radiation exposures of X-rays in some selected areas within the facility were measured. The X-ray machine was operated for a range of kilo voltage peaks of kVp 77, 70, 63 and 66 with intensities 20, 6.3 and 8.0 mAs, which represents the main technique factors of some body parts such as chest, lumbar spine and extremities during radiographic examinations. The measurements were performed using a RADOS-120 Universal survey meter. The radiation doses rates measured in the various locations in the Radiology Department of Cape Coast Teaching Hospital of Ghana were in the range of 0.10 μSv/hr to 0.12 μSv/hr. These values were all within the background measurement of 0.10 μSv/hr. Moreover, there were no risks of high radiation doses to patients, staffs and people visiting the X-ray department. The results obtained indicated that within the radiology department of the Hospital, all the selected locations were very safe to patients, occupational workers and the general public which could be attributed to adequate shielding in the facility.展开更多
文摘During operating of the X-ray machines, if the protection of X-ray rooms is insufficient, not only the patient but also clinical staffs as well as public are exposed to high X-ray dosage and they are affected from X-ray related to the dose level. In the present survey, by testing the radiological leakage and scatter from X-rays machines in radiology departments of 7 randomly selected hospitals in Duhok governorate, the effects dose of X-ray to the both control panel area and the patients waiting or visiting area who are located near the radiography room, were measured. The dose was recorded for a range of peak kilovoltage (kVp) and mAs values to find efficiency of shielding materials (barriers) of radiography rooms for different X-rays level. The measurements were performed at one meter above the ground surface which was the same height of X-rays tube by using Gamma Scout dosimeter. From the measurement results, it was seen that the most hospitals barriers (doors and walls) were not appropriate to the standards except 2 hospitals. The maximum effective doses were measured in uncontrolled area of Khazer hospital which was 82.48 ± 0.73 mSv·yr-1 that was much more than the reference dose limits and in controlled area of Haval Banda Zaroka hospital which was 12.98 ± 0.16 mSv·yr-1. In result, the knowledge about the radiation dose affecting the radiologists and public in the selected hospitals was obtained, and by informing the radiologists and the hospitals managements, the necessary regulations would be planned.
文摘During the operation of an X-ray machine, if the radiation protection of X-ray room is insufficient, not only the patient but also clinical staffs as well as public are exposed to high X-ray exposures. In this research work, leakage and scattered radiations were measured from X-ray machine in the radiology department of Cape Coast Teaching hospital in the Cape Coast Municipality of Ghana. The scattered radiation exposures of X-rays in some selected areas within the facility were measured. The X-ray machine was operated for a range of kilo voltage peaks of kVp 77, 70, 63 and 66 with intensities 20, 6.3 and 8.0 mAs, which represents the main technique factors of some body parts such as chest, lumbar spine and extremities during radiographic examinations. The measurements were performed using a RADOS-120 Universal survey meter. The radiation doses rates measured in the various locations in the Radiology Department of Cape Coast Teaching Hospital of Ghana were in the range of 0.10 μSv/hr to 0.12 μSv/hr. These values were all within the background measurement of 0.10 μSv/hr. Moreover, there were no risks of high radiation doses to patients, staffs and people visiting the X-ray department. The results obtained indicated that within the radiology department of the Hospital, all the selected locations were very safe to patients, occupational workers and the general public which could be attributed to adequate shielding in the facility.