In this paper, reliability analysis for the offshore jacket platform with the interaction of structure- pile- soil under extreme environmental loads is carried out. The inherent uncertainties of the environmental load...In this paper, reliability analysis for the offshore jacket platform with the interaction of structure- pile- soil under extreme environmental loads is carried out. The inherent uncertainties of the environmental load, foundation soil, platform itself, and calculating models are evaluated. The action of extreme loads on the offshore platform is modeled as a function of extreme wave height. The system capacity of the whole platform is determined by nonlinear pushover analysis, and the relevant probability property is obtained by the simulation method. The reliability model for the whole jacket platform is described as the relationship between the load and resistance based on the offshore design codes. The reliability of whole platform is calculated by the analytical method and the importance sampling method on the basis of a case study for a tripod jacket platform.展开更多
The physical models of the outer and inner half coil jackets were simplified to two types of coiled ducts.The mathematic models of incompressible fluid at the condition of laminar flow and heat transfer in the two typ...The physical models of the outer and inner half coil jackets were simplified to two types of coiled ducts.The mathematic models of incompressible fluid at the condition of laminar flow and heat transfer in the two types of jackets for cooling process reactor were set up and solved by the semi-implicit method for pressure linked equa-tions consistent (SIMPLEC) algorithm based on a control volume method.The flow and temperature fields were given and the effects of Dean and Prandtl numbers on flow and heat transfer were studied.The results show that flow in the inner half coil jacket is found to exhibit transition of secondary flow pattern from two vortices to four vortices when the Dean number increases,but that in the outer half coil jacket is not found.The critical Dean num-ber is about 96.The inner half coil jacket has stronger heat transfer ability than the outer half coil jacket and this superiority is more evident with larger Prandtl number.However,as the Dean number is greater than 105,the flow resistance enhances more severely in the inner jacket than the outer jacket.For both jackets,the centers of the heated wall are the poorest for heat transfer.展开更多
为解决具有高黏度、易结垢、强腐蚀性等特点的热敏性物料的蒸发浓缩,设计了夹套式MVR(机械蒸汽再压缩)热泵蒸发浓缩系统,并以水为实验介质进行了相关的实验研究。实验结果表明,温差、压缩比、蒸发量、传热系数、COP(制热性能系数)、...为解决具有高黏度、易结垢、强腐蚀性等特点的热敏性物料的蒸发浓缩,设计了夹套式MVR(机械蒸汽再压缩)热泵蒸发浓缩系统,并以水为实验介质进行了相关的实验研究。实验结果表明,温差、压缩比、蒸发量、传热系数、COP(制热性能系数)、SMER(单位能耗蒸发量)、绝热效率、容积效率等各项指标均受蒸发压力、压缩机频率、换热面积的影响;压缩机在频率50 Hz下运转时的系统性能大大优于低频率运转;单台蒸发釜在蒸发压力为65~85 k Pa之间运行较为合适,且不需要补热;两台蒸发釜完全可以同时应用于工业蒸发浓缩过程,但需要少量的补热;两者节能效果均十分显著。展开更多
文摘In this paper, reliability analysis for the offshore jacket platform with the interaction of structure- pile- soil under extreme environmental loads is carried out. The inherent uncertainties of the environmental load, foundation soil, platform itself, and calculating models are evaluated. The action of extreme loads on the offshore platform is modeled as a function of extreme wave height. The system capacity of the whole platform is determined by nonlinear pushover analysis, and the relevant probability property is obtained by the simulation method. The reliability model for the whole jacket platform is described as the relationship between the load and resistance based on the offshore design codes. The reliability of whole platform is calculated by the analytical method and the importance sampling method on the basis of a case study for a tripod jacket platform.
基金Supported by the National Key Technologies Research and Development Program during the 10th Five-year Plan Period(2004BA319B1)the Educational Commission of Liaoning Province of China(2008S117)
文摘The physical models of the outer and inner half coil jackets were simplified to two types of coiled ducts.The mathematic models of incompressible fluid at the condition of laminar flow and heat transfer in the two types of jackets for cooling process reactor were set up and solved by the semi-implicit method for pressure linked equa-tions consistent (SIMPLEC) algorithm based on a control volume method.The flow and temperature fields were given and the effects of Dean and Prandtl numbers on flow and heat transfer were studied.The results show that flow in the inner half coil jacket is found to exhibit transition of secondary flow pattern from two vortices to four vortices when the Dean number increases,but that in the outer half coil jacket is not found.The critical Dean num-ber is about 96.The inner half coil jacket has stronger heat transfer ability than the outer half coil jacket and this superiority is more evident with larger Prandtl number.However,as the Dean number is greater than 105,the flow resistance enhances more severely in the inner jacket than the outer jacket.For both jackets,the centers of the heated wall are the poorest for heat transfer.
文摘为解决具有高黏度、易结垢、强腐蚀性等特点的热敏性物料的蒸发浓缩,设计了夹套式MVR(机械蒸汽再压缩)热泵蒸发浓缩系统,并以水为实验介质进行了相关的实验研究。实验结果表明,温差、压缩比、蒸发量、传热系数、COP(制热性能系数)、SMER(单位能耗蒸发量)、绝热效率、容积效率等各项指标均受蒸发压力、压缩机频率、换热面积的影响;压缩机在频率50 Hz下运转时的系统性能大大优于低频率运转;单台蒸发釜在蒸发压力为65~85 k Pa之间运行较为合适,且不需要补热;两台蒸发釜完全可以同时应用于工业蒸发浓缩过程,但需要少量的补热;两者节能效果均十分显著。