In today’s fast-paced,information-driven world,data centers can offer high-speed,intricate capabilities on a larger scale owing to the ever-growing demand for networks and information systems.Because data centers pro...In today’s fast-paced,information-driven world,data centers can offer high-speed,intricate capabilities on a larger scale owing to the ever-growing demand for networks and information systems.Because data centers process and transmit information,stability and reliability are important.Data center power supply architectures rely heavily on isolated bidirectional DC-DC converters to ensure safety and stability.For the smooth operation of a data center,the power supply must be reliable and uninterrupted.In this study,we summarize the basic principle,topology,switch conversion strategy,and control technology of the existing isolated bidirectional DC-DC converters.Subsequently,existing research results and problems with isolated bidirectional DC-DC converters are reviewed.Finally,future trends in the development of isolated bidirectional DC-DC converters for data centers are presented,which offer valuable insights for solving engineering obstacles and future research directions in the field.展开更多
针对我国首个±1100 k V特高压直流工程(准东—皖南),研究了直流送受端接入系统方案。首先,对于直流送端系统,考虑直流再启动、闭锁等故障对电网的影响,采用直流安全稳定计算标准,从频率和电压稳定性角度研究送端换流站孤岛接入和...针对我国首个±1100 k V特高压直流工程(准东—皖南),研究了直流送受端接入系统方案。首先,对于直流送端系统,考虑直流再启动、闭锁等故障对电网的影响,采用直流安全稳定计算标准,从频率和电压稳定性角度研究送端换流站孤岛接入和联网接入2种方式的可行性。然后,对于直流受端系统,从提高多馈入短路比、抑制短路电流、平衡潮流分布3个层次,研究受端换流站单层接入500 k V、单层接入1000k V、分层接入1000 k V/500 k V这3种方式的可行性。最后,从受端换流站近区网架结构、接入通道选择等多角度研究并提出了换流站的系统接入网架方案。展开更多
基金Supported by the Natural Science Foundation for Distinguished Young Scholars of Guangdong Province(2022B1515020002).
文摘In today’s fast-paced,information-driven world,data centers can offer high-speed,intricate capabilities on a larger scale owing to the ever-growing demand for networks and information systems.Because data centers process and transmit information,stability and reliability are important.Data center power supply architectures rely heavily on isolated bidirectional DC-DC converters to ensure safety and stability.For the smooth operation of a data center,the power supply must be reliable and uninterrupted.In this study,we summarize the basic principle,topology,switch conversion strategy,and control technology of the existing isolated bidirectional DC-DC converters.Subsequently,existing research results and problems with isolated bidirectional DC-DC converters are reviewed.Finally,future trends in the development of isolated bidirectional DC-DC converters for data centers are presented,which offer valuable insights for solving engineering obstacles and future research directions in the field.
文摘针对我国首个±1100 k V特高压直流工程(准东—皖南),研究了直流送受端接入系统方案。首先,对于直流送端系统,考虑直流再启动、闭锁等故障对电网的影响,采用直流安全稳定计算标准,从频率和电压稳定性角度研究送端换流站孤岛接入和联网接入2种方式的可行性。然后,对于直流受端系统,从提高多馈入短路比、抑制短路电流、平衡潮流分布3个层次,研究受端换流站单层接入500 k V、单层接入1000k V、分层接入1000 k V/500 k V这3种方式的可行性。最后,从受端换流站近区网架结构、接入通道选择等多角度研究并提出了换流站的系统接入网架方案。