A common method to examine the current-limiting performance of saturated iron-core fault current limiter(SI-FCL) in high-voltage direct-current transmission based on voltage source converter(VSC-HVDC) systems is to so...A common method to examine the current-limiting performance of saturated iron-core fault current limiter(SI-FCL) in high-voltage direct-current transmission based on voltage source converter(VSC-HVDC) systems is to solve differential equations based on the system fault transient characteristics and the equivalent inductance calculation equation. This method analyzes the fault current of the VSC-HVDC system in the time domain. However, it is computationally complex and cannot directly reflect the relationship between parameters and the currentlimiting effect of the SI-FCL.In this paper,the relationship between the magnetic flux density and magnetic field energy of the SI-FCL is analyzed. The energy exchange between the DC capacitor and the SI-FCL in the DC short circuit fault process is analyzed. From the perspective of electromagnetic energy conversion, the criterion for determining the current-limiting ability of the SI-FCL in the transient process is given based on the parameters of the SI-FCL and VSC-HVDC system. On this basis, the characteristics of the DC side fault current and the capacitor voltage when the SI-FCL has current-limiting ability are examined.Based on the parameters of the SI-FCL and VSC-HVDC system, a method for calculating the fault current peak value and capacitor voltage drop time is given. Finally, the accuracy of the analysis of the SI-FCL in the VSC-HVDC system based on the electromagnetic energy conversion mechanism is demonstrated through a case study and simulation results of the VSC-HVDC system with different SI-FCLs.展开更多
A special winding iron-core is designed to act as the snubber for the neutral beam injection (NBI) power supply (PS) system in EAST, which will limit the fault current and energy caused by occasional sparking in t...A special winding iron-core is designed to act as the snubber for the neutral beam injection (NBI) power supply (PS) system in EAST, which will limit the fault current and energy caused by occasional sparking in the NBI ion source. 50-50 Ni-Fe is chosen as the high-frequency magnetization material for the iron-core. Equations for the snubber is derived from the design of the iron-core. The iron-loss factor and eddy-current losses are found to increase in a sample experiment at a frequency from 1 kHz to 20 kHz. A 1:10 miniature of the iron-core is tested and performs well with a fine capability.展开更多
基金supported in part by the National Key R&D Program of China (No. 2018YFB0904600)in part by the National Nature Science Foundation of China (NSFC) under Grant 51677125
文摘A common method to examine the current-limiting performance of saturated iron-core fault current limiter(SI-FCL) in high-voltage direct-current transmission based on voltage source converter(VSC-HVDC) systems is to solve differential equations based on the system fault transient characteristics and the equivalent inductance calculation equation. This method analyzes the fault current of the VSC-HVDC system in the time domain. However, it is computationally complex and cannot directly reflect the relationship between parameters and the currentlimiting effect of the SI-FCL.In this paper,the relationship between the magnetic flux density and magnetic field energy of the SI-FCL is analyzed. The energy exchange between the DC capacitor and the SI-FCL in the DC short circuit fault process is analyzed. From the perspective of electromagnetic energy conversion, the criterion for determining the current-limiting ability of the SI-FCL in the transient process is given based on the parameters of the SI-FCL and VSC-HVDC system. On this basis, the characteristics of the DC side fault current and the capacitor voltage when the SI-FCL has current-limiting ability are examined.Based on the parameters of the SI-FCL and VSC-HVDC system, a method for calculating the fault current peak value and capacitor voltage drop time is given. Finally, the accuracy of the analysis of the SI-FCL in the VSC-HVDC system based on the electromagnetic energy conversion mechanism is demonstrated through a case study and simulation results of the VSC-HVDC system with different SI-FCLs.
文摘A special winding iron-core is designed to act as the snubber for the neutral beam injection (NBI) power supply (PS) system in EAST, which will limit the fault current and energy caused by occasional sparking in the NBI ion source. 50-50 Ni-Fe is chosen as the high-frequency magnetization material for the iron-core. Equations for the snubber is derived from the design of the iron-core. The iron-loss factor and eddy-current losses are found to increase in a sample experiment at a frequency from 1 kHz to 20 kHz. A 1:10 miniature of the iron-core is tested and performs well with a fine capability.