对低密度奇偶校验码(LDPC)在AWGN(Additive White Gaussian Noise)信道下的译码算法进行了深入研究,分析了在译码过程中出现突发错误的原因,指出出现这种错误是由于在校验矩阵中存在环路,提出了一种抑制突发错误的软件方法。在该方法中...对低密度奇偶校验码(LDPC)在AWGN(Additive White Gaussian Noise)信道下的译码算法进行了深入研究,分析了在译码过程中出现突发错误的原因,指出出现这种错误是由于在校验矩阵中存在环路,提出了一种抑制突发错误的软件方法。在该方法中,只需对LDPC码的译码程序进行适当控制,就可有效抑制由于环路影响而出现的突发错误,进一步提高了LDPC码的译码性能和译码程序的稳定性,扩大了LDPC码的应用空间。展开更多
With the development of ultra-wide coverage technology,multibeam echo-sounder(MBES)system has put forward higher requirements for localization accuracy and computational efficiency of ray tracing method.The classical ...With the development of ultra-wide coverage technology,multibeam echo-sounder(MBES)system has put forward higher requirements for localization accuracy and computational efficiency of ray tracing method.The classical equivalent sound speed profile(ESSP)method replaces the measured sound velocity profile(SVP)with a simple constant gradient SVP,reducing the computational workload of beam positioning.However,in deep-sea environment,the depth measurement error of this method rapidly increases from the central beam to the edge beam.By analyzing the positioning error of the ESSP method at edge beam,it is discovered that the positioning error increases monotonically with the incident angle,and the relationship between them could be expressed by polynomial function.Therefore,an error correction algorithm based on polynomial fitting is obtained.The simulation experiment conducted on an inclined seafloor shows that the proposed algorithm exhibits comparable efficiency to the original ESSP method,while significantly improving bathymetry accuracy by nearly eight times in the edge beam.展开更多
To explore the method of identifying nursing-related patient safety events, types, contributing factors and evaluate consequences of these events in hospitals of China, incident report program was established and impl...To explore the method of identifying nursing-related patient safety events, types, contributing factors and evaluate consequences of these events in hospitals of China, incident report program was established and implemented in 15 patient units in two teaching hospitals of China to get the relevant information. Among 2935 hospitalized patients, 141 nursing-related patient safety events were reported by nurses. Theses events were categorized into 15 types. Various factors contributed to the events and the consequence varied from no harm to patient death. Most of the events were pre- ventable. It is concluded that incident reporting can provide more information about patient safety, and establishment of a program of voluntary incident reporting in hospitals of China is not only urgent but also feasible.展开更多
This paper describes a broad perspective of the application of graph theory to establishment of GPS control networks whereby the GPS network is considered as a connected and directed graph with three components.In thi...This paper describes a broad perspective of the application of graph theory to establishment of GPS control networks whereby the GPS network is considered as a connected and directed graph with three components.In this algorithm the gross error detection is undertaken through loops of different spanning trees using the "Loop Law" in which the individual components Δ X, Δ Y and Δ Z sum up to zero.If the sum of the respective vector components ∑X,∑Y and ∑Z in a loop is not zero and if the error is beyond the tolerable limit (ε>w),it indicates the existence of gross errors in one of the baselines in the loop and therefore the baseline must be removed or re_observed.After successful screening of errors by graph theory,network adjustment can be carried out.In this paper,the GPS data from the control network established as reference system for the HP Dam at Baishan county in Liaoning province is presented to illustrate the algorithm.展开更多
BACKGROUND: Communication failure in prehospital emergency medicine can affect patient safety as it does in other areas of medicine as well. We analyzed the database of the critical incident reporting system for preho...BACKGROUND: Communication failure in prehospital emergency medicine can affect patient safety as it does in other areas of medicine as well. We analyzed the database of the critical incident reporting system for prehospital emergency medicine in Germany retrospectively regarding communication errors.METHODS: Experts of prehospital emergency medicine and risk management screened the database for verbal communication failure, non-verbal communication failure and missing communication at all.RESULTS: Between 2005 and 2015, 845 reports were analyzed, of which 247 reports were considered to be related to communication failure. An arbitrary classifi cation resulted in six different kinds: 1) no acknowledgement of a suggestion; 2) medication error; 3) miscommunication with dispatcher; 4) utterance heard/understood improperly; 5) missing information transfer between two persons; and 6) other communication failure.CONCLUSION: Communication defi cits can lead to critical incidents in prehospital emergency medicine and are a very important aspect in patient safety.展开更多
文摘对低密度奇偶校验码(LDPC)在AWGN(Additive White Gaussian Noise)信道下的译码算法进行了深入研究,分析了在译码过程中出现突发错误的原因,指出出现这种错误是由于在校验矩阵中存在环路,提出了一种抑制突发错误的软件方法。在该方法中,只需对LDPC码的译码程序进行适当控制,就可有效抑制由于环路影响而出现的突发错误,进一步提高了LDPC码的译码性能和译码程序的稳定性,扩大了LDPC码的应用空间。
基金The Natural Science Foundation of Shandong Province of China under contract Nos ZR2022MA051 and ZR2020MA090the National Natural Science Foundation of China under contract No.U22A2012+2 种基金China Postdoctoral Science Foundation under contract No.2020M670891the SDUST Research Fund under contract No.2019TDJH103the Talent Introduction Plan for Youth Innovation Team in universities of Shandong Province(innovation team of satellite positioning and navigation)。
文摘With the development of ultra-wide coverage technology,multibeam echo-sounder(MBES)system has put forward higher requirements for localization accuracy and computational efficiency of ray tracing method.The classical equivalent sound speed profile(ESSP)method replaces the measured sound velocity profile(SVP)with a simple constant gradient SVP,reducing the computational workload of beam positioning.However,in deep-sea environment,the depth measurement error of this method rapidly increases from the central beam to the edge beam.By analyzing the positioning error of the ESSP method at edge beam,it is discovered that the positioning error increases monotonically with the incident angle,and the relationship between them could be expressed by polynomial function.Therefore,an error correction algorithm based on polynomial fitting is obtained.The simulation experiment conducted on an inclined seafloor shows that the proposed algorithm exhibits comparable efficiency to the original ESSP method,while significantly improving bathymetry accuracy by nearly eight times in the edge beam.
基金supported by a grant from the Bureau of Science and Technology of Hubei Province of China (No.2007AA301B27-7)
文摘To explore the method of identifying nursing-related patient safety events, types, contributing factors and evaluate consequences of these events in hospitals of China, incident report program was established and implemented in 15 patient units in two teaching hospitals of China to get the relevant information. Among 2935 hospitalized patients, 141 nursing-related patient safety events were reported by nurses. Theses events were categorized into 15 types. Various factors contributed to the events and the consequence varied from no harm to patient death. Most of the events were pre- ventable. It is concluded that incident reporting can provide more information about patient safety, and establishment of a program of voluntary incident reporting in hospitals of China is not only urgent but also feasible.
文摘This paper describes a broad perspective of the application of graph theory to establishment of GPS control networks whereby the GPS network is considered as a connected and directed graph with three components.In this algorithm the gross error detection is undertaken through loops of different spanning trees using the "Loop Law" in which the individual components Δ X, Δ Y and Δ Z sum up to zero.If the sum of the respective vector components ∑X,∑Y and ∑Z in a loop is not zero and if the error is beyond the tolerable limit (ε>w),it indicates the existence of gross errors in one of the baselines in the loop and therefore the baseline must be removed or re_observed.After successful screening of errors by graph theory,network adjustment can be carried out.In this paper,the GPS data from the control network established as reference system for the HP Dam at Baishan county in Liaoning province is presented to illustrate the algorithm.
文摘BACKGROUND: Communication failure in prehospital emergency medicine can affect patient safety as it does in other areas of medicine as well. We analyzed the database of the critical incident reporting system for prehospital emergency medicine in Germany retrospectively regarding communication errors.METHODS: Experts of prehospital emergency medicine and risk management screened the database for verbal communication failure, non-verbal communication failure and missing communication at all.RESULTS: Between 2005 and 2015, 845 reports were analyzed, of which 247 reports were considered to be related to communication failure. An arbitrary classifi cation resulted in six different kinds: 1) no acknowledgement of a suggestion; 2) medication error; 3) miscommunication with dispatcher; 4) utterance heard/understood improperly; 5) missing information transfer between two persons; and 6) other communication failure.CONCLUSION: Communication defi cits can lead to critical incidents in prehospital emergency medicine and are a very important aspect in patient safety.