Humid air turbine cycle(HAT)has potential of electrical efficiencies comparable to combined cycle,with lower investment cost and NO_(x) emission.The typical heat exchanger network of HAT consists of intercooler(if the...Humid air turbine cycle(HAT)has potential of electrical efficiencies comparable to combined cycle,with lower investment cost and NO_(x) emission.The typical heat exchanger network of HAT consists of intercooler(if there is),aftercooler,recuperator,economizer and humidifier,which brings higher efficiency but makes the system more complex.To simplify HAT layout,a novel humidifier concept is proposed by integrating the aftercooler into traditional counter-current humidifier.Based on this concept,a one-dimensional model including pressure drop and exergy calculation is established to distinguish the thermodynamic and hydrodynamic characteristics,and then the structural parameters,such as the number of rows and columns,tube diameter,pitch and type for a micro HAT are identified.The results show that the aftercool-humidifier plays the same role as original aftercooler and humidifier,and can match the in-tube air,out-tube air and water stream well with lower volume.In the case of micro HAT cycle,the volume of heat and mass transfer area can be reduced by 47%compared with traditional design.The major thermal resistance occurred in the convection heat transfer process inside the tube;however,using enhanced tube cannot effectively improve the compactness of device.展开更多
Due to the fact that the turbine outlet temperature of aeroderivative three-shaft gas turbine is low,the conventional combined cycle is not suitable for three-shaft gas turbines.However,the humid air turbine(HAT)cycle...Due to the fact that the turbine outlet temperature of aeroderivative three-shaft gas turbine is low,the conventional combined cycle is not suitable for three-shaft gas turbines.However,the humid air turbine(HAT)cycle provides a new choice for aeroderivative gas turbine because the humidification process does not require high temperature.Existing HAT cycle plants are all based on single-shaft gas turbines due to their simple structures,therefore converting aeroderivative three-shaft gas turbine into HAT cycle still lacks sufficient research.This paper proposes a HAT cycle model on a basis of an aeroderivative three-shaft gas turbine.Detailed HAT cycle modelling of saturator,gas turbine and heat exchanger are carried out based on the modular modeling method.The models are verified by simulations on the aeroderivative three-shaft gas turbine.Simulation results show that the studied gas turbine with original size and characteristics could not reach the original turbine inlet temperature because of the introduction of water.However,the efficiency still increases by 0.16%when the HAT cycle runs at the designed power of the simple cycle.Furthermore,simulations considering turbine modifications show that the efficiency could be significantly improved.The results obtained in the paper can provide reference for design and analysis of HAT cycle based on multi-shaft gas turbine especially the aeroderivative gas turbine.展开更多
湿空气透平(Humid air turbine,HAT)循环是当今最先进的燃气轮机循环之一,饱和器水温控制是HAT循环一种通过改变饱和器给水量维持进口水温的控制逻辑。基于上海交通大学HAT循环实验台建立HAT循环模型,分析饱和器水温控制对HAT循环系统...湿空气透平(Humid air turbine,HAT)循环是当今最先进的燃气轮机循环之一,饱和器水温控制是HAT循环一种通过改变饱和器给水量维持进口水温的控制逻辑。基于上海交通大学HAT循环实验台建立HAT循环模型,分析饱和器水温控制对HAT循环系统稳态和动态性能的影响。仿真结果表明,饱和器水温控制可以提高系统变工况运行的效率。对于研究对象,系统效率在75%工况条件下提高0.071%。此外饱和器水温控制可以使得饱和器更快达到稳定,但对HAT循环系统功率调节特性的影响较小。展开更多
Humidification is an important step in humid air turbine system. The calculation on humidification is carried out at 423.15—573.15K, 5—15MPa. The results suggest that to produce high-enthalpy moist air, high water t...Humidification is an important step in humid air turbine system. The calculation on humidification is carried out at 423.15—573.15K, 5—15MPa. The results suggest that to produce high-enthalpy moist air, high water temperature and large water flow are needed. The water temperature is the most sensitive parameter to the humidification tower. And it is better for the humidification tower to work at temperature higher than 523 K when the system pressure is higher than 5 MPa. The comparison between the model used in this paper and ideal model shows that the ideal model can be used in simulation to simply the calculation when the temperature is lower than 473 K and pressure is lower than 5 MPa.展开更多
基金financial support by National Science and Technology Major Project(2017-I-0009-0010)to this research work。
文摘Humid air turbine cycle(HAT)has potential of electrical efficiencies comparable to combined cycle,with lower investment cost and NO_(x) emission.The typical heat exchanger network of HAT consists of intercooler(if there is),aftercooler,recuperator,economizer and humidifier,which brings higher efficiency but makes the system more complex.To simplify HAT layout,a novel humidifier concept is proposed by integrating the aftercooler into traditional counter-current humidifier.Based on this concept,a one-dimensional model including pressure drop and exergy calculation is established to distinguish the thermodynamic and hydrodynamic characteristics,and then the structural parameters,such as the number of rows and columns,tube diameter,pitch and type for a micro HAT are identified.The results show that the aftercool-humidifier plays the same role as original aftercooler and humidifier,and can match the in-tube air,out-tube air and water stream well with lower volume.In the case of micro HAT cycle,the volume of heat and mass transfer area can be reduced by 47%compared with traditional design.The major thermal resistance occurred in the convection heat transfer process inside the tube;however,using enhanced tube cannot effectively improve the compactness of device.
基金Project(2017YFB0903300)supported by the National Key R&D Program of ChinaProject(2016M601593)supported by the China Postdoctoral Science Foundation
文摘Due to the fact that the turbine outlet temperature of aeroderivative three-shaft gas turbine is low,the conventional combined cycle is not suitable for three-shaft gas turbines.However,the humid air turbine(HAT)cycle provides a new choice for aeroderivative gas turbine because the humidification process does not require high temperature.Existing HAT cycle plants are all based on single-shaft gas turbines due to their simple structures,therefore converting aeroderivative three-shaft gas turbine into HAT cycle still lacks sufficient research.This paper proposes a HAT cycle model on a basis of an aeroderivative three-shaft gas turbine.Detailed HAT cycle modelling of saturator,gas turbine and heat exchanger are carried out based on the modular modeling method.The models are verified by simulations on the aeroderivative three-shaft gas turbine.Simulation results show that the studied gas turbine with original size and characteristics could not reach the original turbine inlet temperature because of the introduction of water.However,the efficiency still increases by 0.16%when the HAT cycle runs at the designed power of the simple cycle.Furthermore,simulations considering turbine modifications show that the efficiency could be significantly improved.The results obtained in the paper can provide reference for design and analysis of HAT cycle based on multi-shaft gas turbine especially the aeroderivative gas turbine.
文摘湿空气透平(Humid air turbine,HAT)循环是当今最先进的燃气轮机循环之一,饱和器水温控制是HAT循环一种通过改变饱和器给水量维持进口水温的控制逻辑。基于上海交通大学HAT循环实验台建立HAT循环模型,分析饱和器水温控制对HAT循环系统稳态和动态性能的影响。仿真结果表明,饱和器水温控制可以提高系统变工况运行的效率。对于研究对象,系统效率在75%工况条件下提高0.071%。此外饱和器水温控制可以使得饱和器更快达到稳定,但对HAT循环系统功率调节特性的影响较小。
基金Supported by the Natural Science Foundation of Jiangsu Province (BK97124) the National Natural Science Foundation (No. 20376032)+1 种基金 the Outstanding Youth Fund of National Natural Science Foundation (No. 29925616)Key Fund of National Natural Science Fo
文摘Humidification is an important step in humid air turbine system. The calculation on humidification is carried out at 423.15—573.15K, 5—15MPa. The results suggest that to produce high-enthalpy moist air, high water temperature and large water flow are needed. The water temperature is the most sensitive parameter to the humidification tower. And it is better for the humidification tower to work at temperature higher than 523 K when the system pressure is higher than 5 MPa. The comparison between the model used in this paper and ideal model shows that the ideal model can be used in simulation to simply the calculation when the temperature is lower than 473 K and pressure is lower than 5 MPa.