To investigate the seismic performance of hollow reinforced concrete (RC) bridge columns of rectangular cross section under constant axial load and cyclically biaxial bending, five specimens were tested. A parametri...To investigate the seismic performance of hollow reinforced concrete (RC) bridge columns of rectangular cross section under constant axial load and cyclically biaxial bending, five specimens were tested. A parametric study is carried out for different axial load ratios, longitudinal reinforcement ratios and lateral reinforcement ratios. The experimental results showed that all tested specimens failed in the flexural failure mode and their ultimate performance was dominated by flexural capacity, which is represented by the rupture/buckling of tensile longitudinal rebars at the bottom of the bridge columns. Biaxial force and displacement hysteresis loops showed significant stiffness and strength degradations, and the pinching effect and coupling interaction effect of both directions severely decrease the structural seismic resistance. However, the measured ductility coefficient varying from 3.5 to 5.7 and the equivalent viscous damping ratio varying from 0.19 and 0.26 can meet the requirements of the seismic design. The hollow RC rectangular bridge columns with configurations of lateral reinforcement in this study have excellent performance under bidirectional earthquake excitations, and may be considered as a substitute for current hollow RC rectangular section configurations described in the Guideline for Seismic Design of Highway Bridges (JTG/T B02-01-2008). The length of the plastic hinge region was found to approach one sixth of the hollow RC rectangular bridge column height for all specimen columns, and it was much less than those specified in the current JTG/T. Thus, the length of the plastic hinge region is more concentrated for RC rectangular hollow bridge columns.展开更多
Currently the design scheme ofprecast hollow concrete bridge piers will be adopted in bridge design in China, but there is no code including specific design details of precast segmental piers in high seismic risk area...Currently the design scheme ofprecast hollow concrete bridge piers will be adopted in bridge design in China, but there is no code including specific design details of precast segmental piers in high seismic risk area. For comparative study of seismic performance of the hollow bridge piers which had different design details, six specimens of hollow section bridge pier were designed and tested. The specimens consist of the monolithic cast-in-place concrete bridge pier, precast segmental prestressed pier with cast-in-place joint and precast segmental concrete bridge pier with dry joints. Results show that all specimens have good displacement capacity. The bridge pier with bonded prestressed strands exhibits better energy dissipation capacity and higher strength. The un-bonded prestressed strand bridge pier displays less residual plastic displacement and energy dissipation capacity. The bridge pier with both bonded prestressed strands at the edge of the section and un-bonded in the center of the section not only exhibits more ductility capacity and less residual plastic displacement, but also shows better energy dissipation capacity. Compared with experimental results of prestressed bridge columns, analytical result demonstrates the developed numerical analysis model would provide the reasonable and accurate results.展开更多
基金National Natural Science Foundation of China under Grant No.51178008,No.50908005National Basic Research Program of China under Grant No.2011CB013600+1 种基金the International Cooperative Project of NSFC-JST under Grant No.51021140003a Joint Research Project between the Beijing University of Technology and the University at Buffalo with Partial Support from the U.S.Federal Highway Administration under Contract No.DTFH61-07-C-00020
文摘To investigate the seismic performance of hollow reinforced concrete (RC) bridge columns of rectangular cross section under constant axial load and cyclically biaxial bending, five specimens were tested. A parametric study is carried out for different axial load ratios, longitudinal reinforcement ratios and lateral reinforcement ratios. The experimental results showed that all tested specimens failed in the flexural failure mode and their ultimate performance was dominated by flexural capacity, which is represented by the rupture/buckling of tensile longitudinal rebars at the bottom of the bridge columns. Biaxial force and displacement hysteresis loops showed significant stiffness and strength degradations, and the pinching effect and coupling interaction effect of both directions severely decrease the structural seismic resistance. However, the measured ductility coefficient varying from 3.5 to 5.7 and the equivalent viscous damping ratio varying from 0.19 and 0.26 can meet the requirements of the seismic design. The hollow RC rectangular bridge columns with configurations of lateral reinforcement in this study have excellent performance under bidirectional earthquake excitations, and may be considered as a substitute for current hollow RC rectangular section configurations described in the Guideline for Seismic Design of Highway Bridges (JTG/T B02-01-2008). The length of the plastic hinge region was found to approach one sixth of the hollow RC rectangular bridge column height for all specimen columns, and it was much less than those specified in the current JTG/T. Thus, the length of the plastic hinge region is more concentrated for RC rectangular hollow bridge columns.
基金This research was supported by the National Science Foundation of China (Grant Nos. 51408360, 51178350, and 51378386), and by Science and Technology Commission of Shanghai Municipality under Research (Grant Nos. 13QH1400300, 12231201300, 13231200802), and their assistances are gratefully acknowledged.
文摘Currently the design scheme ofprecast hollow concrete bridge piers will be adopted in bridge design in China, but there is no code including specific design details of precast segmental piers in high seismic risk area. For comparative study of seismic performance of the hollow bridge piers which had different design details, six specimens of hollow section bridge pier were designed and tested. The specimens consist of the monolithic cast-in-place concrete bridge pier, precast segmental prestressed pier with cast-in-place joint and precast segmental concrete bridge pier with dry joints. Results show that all specimens have good displacement capacity. The bridge pier with bonded prestressed strands exhibits better energy dissipation capacity and higher strength. The un-bonded prestressed strand bridge pier displays less residual plastic displacement and energy dissipation capacity. The bridge pier with both bonded prestressed strands at the edge of the section and un-bonded in the center of the section not only exhibits more ductility capacity and less residual plastic displacement, but also shows better energy dissipation capacity. Compared with experimental results of prestressed bridge columns, analytical result demonstrates the developed numerical analysis model would provide the reasonable and accurate results.