Experimental study on heat exchange of several types of exchangers
1
作者 周志华 赵振华 于洋 《Journal of Central South University》 SCIE EI CAS 2009年第S1期204-208,共5页
Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers bu... Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers buried directly. The result indicates that the heat exchanger makes the best use of structure of building,saves land,reduces the construction cost,and the heat exchanged is obviously more than exchangers buried directly. In winter condition,when W-shape pipe heat exchanger in pile foundation is 50 m deep and diameter is 800 mm,it transfers 1.2-1.3 times as large as the one of single U-shape buried directly at the flow rate of 0.6 m/s,whose borehole diameter is 300 mm. And in summer condition it does about 2.0-2.3 times as that of U-shape one. 展开更多
关键词 ground-coupled source heat pump heat exchanger in pile foundation single U-shape pipe heat exchanger BURIED directly heat exchange
下载PDF
桩基螺旋地埋管换热器模型与换热性能研究 被引量:5
2
作者 吴华剑 付祥钊 刘希臣 《煤气与热力》 2012年第10期27-31,共5页
以线热源理论为基础,结合格林函数法中的持续热源法,建立了桩基螺旋地埋管换热器准三维模型,采用Matlab程序对模型进行编程计算。在设定条件下,分析了土壤热导率、土壤初始温度、螺旋地埋管螺距、桩基半径、管内流体流速对桩基螺旋地埋... 以线热源理论为基础,结合格林函数法中的持续热源法,建立了桩基螺旋地埋管换热器准三维模型,采用Matlab程序对模型进行编程计算。在设定条件下,分析了土壤热导率、土壤初始温度、螺旋地埋管螺距、桩基半径、管内流体流速对桩基螺旋地埋管换热器换热性能的影响。 展开更多
关键词 桩基螺旋地埋管换热器 线热源 持续热源法 换热性能
下载PDF
桩基地埋管对土壤温度的影响及换热性能研究
3
作者 吴华剑 戴会英 付祥钊 《煤气与热力》 2015年第11期11-15,共5页
结合实际工程,采用实验方法研究桩基螺旋地埋管换热器运行阶段周围土壤温度的变化,以及换热性能的影响因素。运行期间,深度越大土壤温度越高,随着换热时间的延长,接近地面的土壤温度增速明显高于深度更大的土壤。与单组螺旋地埋管运行相... 结合实际工程,采用实验方法研究桩基螺旋地埋管换热器运行阶段周围土壤温度的变化,以及换热性能的影响因素。运行期间,深度越大土壤温度越高,随着换热时间的延长,接近地面的土壤温度增速明显高于深度更大的土壤。与单组螺旋地埋管运行相比,三组螺旋地埋管运行对土壤温升作用明显。对于单组螺旋地埋管换热器的运行工况,流速从0.6 m/s增至0.8 m/s时,单位孔深换热量仅增加3.8%。对于三组螺旋地埋管运行工况,在加热功率相同的条件下,水流量为1.71 m^3/h时的单位孔深换热量与流量为2.1 m^3/h时相差不大,建议采用小流量大温差运行。 展开更多
关键词 桩基螺旋地埋管换热器 土壤温度 换热性能