Radiation induced graft polymerization on polymeric matrix followed by functionalization is widely accepted for the preparation of metal adsorbents. In this paper, a pre-irradiation method was used for emulsion graft ...Radiation induced graft polymerization on polymeric matrix followed by functionalization is widely accepted for the preparation of metal adsorbents. In this paper, a pre-irradiation method was used for emulsion graft polymerization of 4-hydroxybutyl acrylate glycidylether (4-HB) onto polyethylene/polypropylene (PE/PP) nonwoven fabric. The degree of grafting (Dg) which can be calculated by weight increment was determined as a function of reaction time, irradiation dose, and monomer concentration. After 30 kGy irradiation, with 4-HB concentration of 5%, surfactant Span 20 of 0.5% at 40°C for 2 h, the trunk polymer was made grafted at a Dg of 135%. 4-HB-grafted PE/PP nonwoven fabric was modified by ethylenediamine (EDA) in isopropyl alcohol (IPA) as a solvent at 60°C. With a Dg of 135%, the amine group density of the adsorbent is 2.8 mmol/g. The adsorption test was carried out by batch experiment in several metal ion solutions, and the removal ratio from the EDA modified adsorbent of the metal ions is in the order of Cu2+ > Pb2+ > Zn2+ > Ni2+ > Li+. Compared with glycidyl methacrylate (GMA) which is a typical functional monomer for graft polymerization, 4-HB-grafted adsorbent exhibited not only better mechanical property but also higher adsorption capacity of Cu2+ and Pb2+.展开更多
In order to explore whether the protective function of GST-pi can prevent transformation in vitro, NIH3T3 cells and carcinogen glycidyl methacrylate (GMA) have been used in cell transformation study. NIH3T3 cells have...In order to explore whether the protective function of GST-pi can prevent transformation in vitro, NIH3T3 cells and carcinogen glycidyl methacrylate (GMA) have been used in cell transformation study. NIH3T3 cells have been transfected with GST-pi cDNA inserted retrovirus vector, pXT1, and then G418 resistant clones have been analyzed by Southern and Northern analyses. NIH3T3/pXGST clones that stably express GST-pi and control cells,展开更多
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been combined with immobilized enzyme microreactor for the rapid, sensitive, and accurate tryptic mapping of protein and polypeptides. The t...Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been combined with immobilized enzyme microreactor for the rapid, sensitive, and accurate tryptic mapping of protein and polypeptides. The technique utilizes the trypsin microreactor by immobilized enzyme on the glycidyl methacrylate (GMA)-modified cellulose membrane. The membrane micro-reactor was used for the tryptic mapping of cytochrome C and the results were compared with those obtained by using free trypsin. A significant increase in the overall sensitivity of the process was observed using the membrane microreactor, as well as the elimination of background signals due to the autolysis of the trypsin. Further, membrane microreactor digestions were found to be rapid and convenient.展开更多
文摘Radiation induced graft polymerization on polymeric matrix followed by functionalization is widely accepted for the preparation of metal adsorbents. In this paper, a pre-irradiation method was used for emulsion graft polymerization of 4-hydroxybutyl acrylate glycidylether (4-HB) onto polyethylene/polypropylene (PE/PP) nonwoven fabric. The degree of grafting (Dg) which can be calculated by weight increment was determined as a function of reaction time, irradiation dose, and monomer concentration. After 30 kGy irradiation, with 4-HB concentration of 5%, surfactant Span 20 of 0.5% at 40°C for 2 h, the trunk polymer was made grafted at a Dg of 135%. 4-HB-grafted PE/PP nonwoven fabric was modified by ethylenediamine (EDA) in isopropyl alcohol (IPA) as a solvent at 60°C. With a Dg of 135%, the amine group density of the adsorbent is 2.8 mmol/g. The adsorption test was carried out by batch experiment in several metal ion solutions, and the removal ratio from the EDA modified adsorbent of the metal ions is in the order of Cu2+ > Pb2+ > Zn2+ > Ni2+ > Li+. Compared with glycidyl methacrylate (GMA) which is a typical functional monomer for graft polymerization, 4-HB-grafted adsorbent exhibited not only better mechanical property but also higher adsorption capacity of Cu2+ and Pb2+.
文摘In order to explore whether the protective function of GST-pi can prevent transformation in vitro, NIH3T3 cells and carcinogen glycidyl methacrylate (GMA) have been used in cell transformation study. NIH3T3 cells have been transfected with GST-pi cDNA inserted retrovirus vector, pXT1, and then G418 resistant clones have been analyzed by Southern and Northern analyses. NIH3T3/pXGST clones that stably express GST-pi and control cells,
文摘Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been combined with immobilized enzyme microreactor for the rapid, sensitive, and accurate tryptic mapping of protein and polypeptides. The technique utilizes the trypsin microreactor by immobilized enzyme on the glycidyl methacrylate (GMA)-modified cellulose membrane. The membrane micro-reactor was used for the tryptic mapping of cytochrome C and the results were compared with those obtained by using free trypsin. A significant increase in the overall sensitivity of the process was observed using the membrane microreactor, as well as the elimination of background signals due to the autolysis of the trypsin. Further, membrane microreactor digestions were found to be rapid and convenient.