Detection of gas decomposition products is widely used for condition diagnosis of SF6-insulated equipment because of its an- ti-electromagnetic-interference ability and high sensitivity. Previous investigations show t...Detection of gas decomposition products is widely used for condition diagnosis of SF6-insulated equipment because of its an- ti-electromagnetic-interference ability and high sensitivity. Previous investigations show that the volume of gas chamber influences the types and concentrations of SF6 decomposition products. Therefore using a newly developed dual gas chromatography (GC) detection sys- tem we investigated the discharge and decomposition of SF6 in a discharge chamber with its volume close to that of the real chambers in GIS. Tests in the chamber were performed with different applied voltage, different electrode arrangements, and different defect types. For discharge between needle-to-plane electrodes, the typical gas decomposition products are SO2F2, SO2 and S2OF10. A near linear growth with the increase of voltage duration is found in the concentration of SO2F2, whereas the growth rates of SO2 and S2OF10 concentration decrease with time. Concentrations of SO2F2, SO2 and S2OF10 at the same voltage duration decrease with the decrease of the voltage amplitude and the increase of the needle-to-plane distance. Change of the gas chamber volume affects the generation rates of SO2F2 and SO2, however not S2OF10. For insulator surface defects, the typical gas decomposition products are CF4, CS2 and SO2. Among which, the concentrations of CF4 and SO2 increase with the voltage duration almost linearly. Moreover, a new parameter that represents the degree of SF6 degradation, the SF6 deterioration ratio, is proposed. In the needle-to-plane case, SF6 deterioration ratio is positively correlated to the fitting value of an averaged discharge capacity. However, the maximum value of SF6 deterioration ratio varies with the defect type.展开更多
Recent advancements in person-portable instrumentation have resulted in the potential to provide contemporaneous results through rapid in-field analyses.These technologies can be utilised in emergency response scenari...Recent advancements in person-portable instrumentation have resulted in the potential to provide contemporaneous results through rapid in-field analyses.These technologies can be utilised in emergency response scenarios to aid first responders in appropriate site risk assessment and management.Large metropolitan fires can pose great risk to human and environmental health due to the rapid release of hazardous compounds into the atmosphere.Understanding the release of these hazardous organics is critical in understanding their associated risks.Person-portable gas chromatography-mass spectrometry(GC-MS)was evaluated for its potential to provide rapid on-site analysis for real-time monitoring of hazardous organic compounds at fire scenes.Air sampling and analysis methods were developed for scenes of this nature.Controlled field testing demonstrated that the portable GC-MS was able to provide preliminary analytical results on the volatile organic compounds present in air samples collected from both active and extinguished fires.In-field results were confirmed using conventional laboratory-based air sampling and analysis procedures.The deployment of portable instrumentation could provide first responders with a rapid on-site assessment tool for the appropriate management of scenes,thereby ensuring environmental and human health is proactively protected and scientifically informed decisions are made for the provision of timely advice to stakeholders.展开更多
To understand the discharge characteristics under a gap of micrometers,the breakdown voltage and current–voltage curve are measured experimentally in a needle-to-plate electrode at a microscale gap of 3–50 μm in ai...To understand the discharge characteristics under a gap of micrometers,the breakdown voltage and current–voltage curve are measured experimentally in a needle-to-plate electrode at a microscale gap of 3–50 μm in air.The effect of the needle radius and the gas pressure on the discharge characteristics are tested.The results show that when the gap is larger than 10 μm,the relation between the breakdown voltage and the gap looks like the Paschen curve;while below 10 μm,the breakdown voltage is nearly constant in the range of the tested gap.However,at the same gap distance,the breakdown voltage is still affected by the pressure and shows a trend similar to Paschen's law.The current–voltage characteristic in all the gaps is similar and follows the trend of a typical Townsend-to-glow discharge.A simple model is used to explain the non-normality of breakdown in the micro-gaps.The Townsend mechanism is suggested to control the breakdown process in this configuration before the gap reduces much smaller in air.展开更多
基金Project supported by International Cooperation Project in Shaanxi Province of China (2012KW-01)
文摘Detection of gas decomposition products is widely used for condition diagnosis of SF6-insulated equipment because of its an- ti-electromagnetic-interference ability and high sensitivity. Previous investigations show that the volume of gas chamber influences the types and concentrations of SF6 decomposition products. Therefore using a newly developed dual gas chromatography (GC) detection sys- tem we investigated the discharge and decomposition of SF6 in a discharge chamber with its volume close to that of the real chambers in GIS. Tests in the chamber were performed with different applied voltage, different electrode arrangements, and different defect types. For discharge between needle-to-plane electrodes, the typical gas decomposition products are SO2F2, SO2 and S2OF10. A near linear growth with the increase of voltage duration is found in the concentration of SO2F2, whereas the growth rates of SO2 and S2OF10 concentration decrease with time. Concentrations of SO2F2, SO2 and S2OF10 at the same voltage duration decrease with the decrease of the voltage amplitude and the increase of the needle-to-plane distance. Change of the gas chamber volume affects the generation rates of SO2F2 and SO2, however not S2OF10. For insulator surface defects, the typical gas decomposition products are CF4, CS2 and SO2. Among which, the concentrations of CF4 and SO2 increase with the voltage duration almost linearly. Moreover, a new parameter that represents the degree of SF6 degradation, the SF6 deterioration ratio, is proposed. In the needle-to-plane case, SF6 deterioration ratio is positively correlated to the fitting value of an averaged discharge capacity. However, the maximum value of SF6 deterioration ratio varies with the defect type.
基金This project has been assisted by the New South Wales Government through its Environmental Trust[grant number 2015/RD/0156].
文摘Recent advancements in person-portable instrumentation have resulted in the potential to provide contemporaneous results through rapid in-field analyses.These technologies can be utilised in emergency response scenarios to aid first responders in appropriate site risk assessment and management.Large metropolitan fires can pose great risk to human and environmental health due to the rapid release of hazardous compounds into the atmosphere.Understanding the release of these hazardous organics is critical in understanding their associated risks.Person-portable gas chromatography-mass spectrometry(GC-MS)was evaluated for its potential to provide rapid on-site analysis for real-time monitoring of hazardous organic compounds at fire scenes.Air sampling and analysis methods were developed for scenes of this nature.Controlled field testing demonstrated that the portable GC-MS was able to provide preliminary analytical results on the volatile organic compounds present in air samples collected from both active and extinguished fires.In-field results were confirmed using conventional laboratory-based air sampling and analysis procedures.The deployment of portable instrumentation could provide first responders with a rapid on-site assessment tool for the appropriate management of scenes,thereby ensuring environmental and human health is proactively protected and scientifically informed decisions are made for the provision of timely advice to stakeholders.
基金supported by National Natural Science Foundation of China(11475019)the Electrostatic Research Foundation of Liu Shanghe Academicians and Experts Workstation,Beijing Orient Institute of Measurement and Test(BOIMTLSHJD20161002)
文摘To understand the discharge characteristics under a gap of micrometers,the breakdown voltage and current–voltage curve are measured experimentally in a needle-to-plate electrode at a microscale gap of 3–50 μm in air.The effect of the needle radius and the gas pressure on the discharge characteristics are tested.The results show that when the gap is larger than 10 μm,the relation between the breakdown voltage and the gap looks like the Paschen curve;while below 10 μm,the breakdown voltage is nearly constant in the range of the tested gap.However,at the same gap distance,the breakdown voltage is still affected by the pressure and shows a trend similar to Paschen's law.The current–voltage characteristic in all the gaps is similar and follows the trend of a typical Townsend-to-glow discharge.A simple model is used to explain the non-normality of breakdown in the micro-gaps.The Townsend mechanism is suggested to control the breakdown process in this configuration before the gap reduces much smaller in air.