Electrical pole-changing technology leads to torque ripple and speed fluctuation despite broadening the constant power speed range of the multiphase induction machine (IM) system. To reduce the torque ripple and spe...Electrical pole-changing technology leads to torque ripple and speed fluctuation despite broadening the constant power speed range of the multiphase induction machine (IM) system. To reduce the torque ripple and speed fluctuation of the machine, we investigate an exponential response electrical pole-changing method for five-phase IM with a current sliding-mode control strategy. This control strategy employs the dual-plane (dr-q1 and d2-q2) vector control method, which allows the IM to operate under different pole modes. Current sliding-mode controllers are applied instead of conventional proportional integral (PI) controllers to adjust the current vectors, and exponential current response achieves a smooth transition between the d1-q1 and d2-q2 planes. Compared with the step response pole-changing with PI control method, the proposed pole-changing method greatly reduces the torque ripple and speed fluctuation of the IM during the pole-changing process. Experimental results verify the ex- ceptional performance of the proposed electrical pole-changing strategy.展开更多
Model predictive current control(MPCC)and model predictive torque control(MPTC)are two derivatives of model predictive control.These two control methods have demonstrated their strengths in the fault-tolerant control ...Model predictive current control(MPCC)and model predictive torque control(MPTC)are two derivatives of model predictive control.These two control methods have demonstrated their strengths in the fault-tolerant control of multiphase motor drives.To explore the inherent link,the pros and cons of two strategies,the performance analysis and comparative investigation of MPCC and MPTC are conducted through a five-phase permanent magnet synchronous motor with open-phase fault.In MPCC,the currents of fundamental and harmonic subspaces are simultaneously employed and constrained for a combined regulation of the open-circuit fault drive.In MPTC,apart from the torque and the stator flux related to fundamental subspace,the x-y currents are also considered and predicted to achieve the control of harmonic subspace.The principles of two methods are demonstrated in detail and the link is explored in terms of the cost function.Besides,the performance by two methods is experimentally assessed in terms of steady-state,transition,and dynamic tests.Finally,the advantages and disadvantages of each method are concluded.展开更多
In this paper,a robust torque speed estimator(RTSE)for linear parameter changing(LPC)system is proposed and designed for an encoderless five-phase permanent magnet assisted synchronous reluctance motor(5-phase PMa-Syn...In this paper,a robust torque speed estimator(RTSE)for linear parameter changing(LPC)system is proposed and designed for an encoderless five-phase permanent magnet assisted synchronous reluctance motor(5-phase PMa-SynRM).This estimator is utilized for estimating the rotor speed and the load torque as well as can solve the speed sensor fault problem,as the feedback speed information is obtained directly from the virtual sensor.In addition,this technique is able to enhance the 5-phase PMa-SynRM performance by estimating the load torque for the real time compensation.The stability analysis of the proposed estimator is performed via Schur complement along with Lyapunov analysis.Furthermore,for improving the 5-phase PMa-SynRM performance,five super-twisting sliding mode controllers(ST-SMCs)are employed with providing a robust response without the impacts of high chattering problem.A super-twisting sliding mode speed controller(ST-SMSC)is employed for controlling the PMa-SynRM rotor speed,and four super-twisting sliding mode current controllers(ST-SMCCs)are employed for controlling the 5-phase PMa-SynRM currents.The stability analysis and the experimental results indicate the effectiveness along with feasibility of the proposed RTSE and the ST-SMSC with ST-SMCCs approach for a 750-W 5-phase PMa-SynRM under load disturbance,parameters variations,single open-phase fault,and adjacent two-phase open circuit fault conditions.展开更多
In this paper,research into torque ripple production has been undertaken for both the healthy and open-circuit faulttolerant conditions of a five-phase permanent magnet(PM)machine by using the instantaneous power(I-Po...In this paper,research into torque ripple production has been undertaken for both the healthy and open-circuit faulttolerant conditions of a five-phase permanent magnet(PM)machine by using the instantaneous power(I-Power)approach.When only the fundamental component of the phase currents is applied to the phase windings,it has been shown that the 9th and 11th harmonics of the back-electromotive force(back-EMF)causes torque ripples in a five-phase PM machine and its frequency is ten times the frequency of the fundamental phase currents.When the combined fundamental and third harmonic components of the phase currents are applied to the phase windings,it has been shown that the 7th and 13th harmonic of the back-electromotive force(back-EMF)causes additional torque ripples in a five-phase PM machine.These torque ripples under fault-tolerant conditions have been analyzed analytically,as well.It has been proven that there are interactions between the fundamental component of current and the third harmonic component of the back-EMF and vice versa.These interactions cause torque ripples.A finite element analysis(FEA)model of the five-phase PM machine has been done to validate the analytical results.展开更多
The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-to...The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-tolerant control strategy based on decoupling control and stator current compensation is proposed for the propulsion system of five-phase PMSM with independent neutrals.Firstly,the mathematical model of PMSM is established by using vector space decoupling method;Secondly,a stator current compensation method is adopted to carry out fault-tolerant control after the motor has single-phase and two-phase open-circuit faults and the fault-tolerant control system based on decoupling control is established;Finally,the decoupling control model and the fault-tolerant control of stator current compensation are verified by the simulation and experiment.The simulation and experiment results show that the method can reduce the torque ripple caused by the stator winding open-circuit fault,and the operation performance of the motor under fault condition is significantly improved.展开更多
Using traditional five-interferogram algorithm to unwrap phase for length measurement, the phase steps must be equal to π/2 exactly, but it is almost impossible to achieve in nanometer positioning technique. Aiming t...Using traditional five-interferogram algorithm to unwrap phase for length measurement, the phase steps must be equal to π/2 exactly, but it is almost impossible to achieve in nanometer positioning technique. Aiming to overcome this defect of traditional five-interferogram algorithm, an improved five-interferogram algorithm is presented. This improved algorithm not only keeps the high accuracy of traditional fiveinterferogram algorithm, but also does not need absolute equal step to unwrap phase. Instead, this algorithm only needs measuring phase-shifting. With the numerical simulation, the improved five-interferogram algorithm shows high accuracy, high reliability, and feasibility in practice. It is very valuable for accurate length measurement with Fizeau interferometer and Fabry-Perot interferometer.展开更多
The main drawbacks of traditional finite set model predictive control are high computational load,large torque ripple,and variable switching frequency.A less complex deadbeat(DB)model predictive current control(MPCC)w...The main drawbacks of traditional finite set model predictive control are high computational load,large torque ripple,and variable switching frequency.A less complex deadbeat(DB)model predictive current control(MPCC)with improved space vector pulse-width modulation(SVPWM)under a single-phase open-circuit fault is proposed.The proposed method predicts the reference voltage vector in the a-β subspace by employing the deadbeat control principle on the machine predictive model;thus,the exhaustive exploration procedure is avoided to relieve the computational load.To perform the constant switching frequency operation and achieve better steady-state performance,a modified SVPWM strategy is developed with the same conventional structure,which modulates the reference voltage vector.This new approach is based on a redesigned and adjusted post-fault virtual voltage vector space distribution that eliminates the y-axis harmonic components in the x-y subspace and ensures the generation of symmetrical PWM pulses.Meanwhile,the combined merits of the DB,MPCC,and SVPWM methods are realized.To verify the effectiveness of the proposed control scheme,comparative experiments are performed on a five-phase permanent magnet synchronous motor(PMSM)drive system.展开更多
基金Project supported by the National Basic Research Program(973)of China(No.2013CB035600)
文摘Electrical pole-changing technology leads to torque ripple and speed fluctuation despite broadening the constant power speed range of the multiphase induction machine (IM) system. To reduce the torque ripple and speed fluctuation of the machine, we investigate an exponential response electrical pole-changing method for five-phase IM with a current sliding-mode control strategy. This control strategy employs the dual-plane (dr-q1 and d2-q2) vector control method, which allows the IM to operate under different pole modes. Current sliding-mode controllers are applied instead of conventional proportional integral (PI) controllers to adjust the current vectors, and exponential current response achieves a smooth transition between the d1-q1 and d2-q2 planes. Compared with the step response pole-changing with PI control method, the proposed pole-changing method greatly reduces the torque ripple and speed fluctuation of the IM during the pole-changing process. Experimental results verify the ex- ceptional performance of the proposed electrical pole-changing strategy.
基金supported in part by the Fundamental Research Funds for Central Universities under Grant JUSRP121020the Natural Science Foundation of Jiangsu Province under Grant BK20210475。
文摘Model predictive current control(MPCC)and model predictive torque control(MPTC)are two derivatives of model predictive control.These two control methods have demonstrated their strengths in the fault-tolerant control of multiphase motor drives.To explore the inherent link,the pros and cons of two strategies,the performance analysis and comparative investigation of MPCC and MPTC are conducted through a five-phase permanent magnet synchronous motor with open-phase fault.In MPCC,the currents of fundamental and harmonic subspaces are simultaneously employed and constrained for a combined regulation of the open-circuit fault drive.In MPTC,apart from the torque and the stator flux related to fundamental subspace,the x-y currents are also considered and predicted to achieve the control of harmonic subspace.The principles of two methods are demonstrated in detail and the link is explored in terms of the cost function.Besides,the performance by two methods is experimentally assessed in terms of steady-state,transition,and dynamic tests.Finally,the advantages and disadvantages of each method are concluded.
文摘In this paper,a robust torque speed estimator(RTSE)for linear parameter changing(LPC)system is proposed and designed for an encoderless five-phase permanent magnet assisted synchronous reluctance motor(5-phase PMa-SynRM).This estimator is utilized for estimating the rotor speed and the load torque as well as can solve the speed sensor fault problem,as the feedback speed information is obtained directly from the virtual sensor.In addition,this technique is able to enhance the 5-phase PMa-SynRM performance by estimating the load torque for the real time compensation.The stability analysis of the proposed estimator is performed via Schur complement along with Lyapunov analysis.Furthermore,for improving the 5-phase PMa-SynRM performance,five super-twisting sliding mode controllers(ST-SMCs)are employed with providing a robust response without the impacts of high chattering problem.A super-twisting sliding mode speed controller(ST-SMSC)is employed for controlling the PMa-SynRM rotor speed,and four super-twisting sliding mode current controllers(ST-SMCCs)are employed for controlling the 5-phase PMa-SynRM currents.The stability analysis and the experimental results indicate the effectiveness along with feasibility of the proposed RTSE and the ST-SMSC with ST-SMCCs approach for a 750-W 5-phase PMa-SynRM under load disturbance,parameters variations,single open-phase fault,and adjacent two-phase open circuit fault conditions.
文摘In this paper,research into torque ripple production has been undertaken for both the healthy and open-circuit faulttolerant conditions of a five-phase permanent magnet(PM)machine by using the instantaneous power(I-Power)approach.When only the fundamental component of the phase currents is applied to the phase windings,it has been shown that the 9th and 11th harmonics of the back-electromotive force(back-EMF)causes torque ripples in a five-phase PM machine and its frequency is ten times the frequency of the fundamental phase currents.When the combined fundamental and third harmonic components of the phase currents are applied to the phase windings,it has been shown that the 7th and 13th harmonic of the back-electromotive force(back-EMF)causes additional torque ripples in a five-phase PM machine.These torque ripples under fault-tolerant conditions have been analyzed analytically,as well.It has been proven that there are interactions between the fundamental component of current and the third harmonic component of the back-EMF and vice versa.These interactions cause torque ripples.A finite element analysis(FEA)model of the five-phase PM machine has been done to validate the analytical results.
文摘The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-tolerant control strategy based on decoupling control and stator current compensation is proposed for the propulsion system of five-phase PMSM with independent neutrals.Firstly,the mathematical model of PMSM is established by using vector space decoupling method;Secondly,a stator current compensation method is adopted to carry out fault-tolerant control after the motor has single-phase and two-phase open-circuit faults and the fault-tolerant control system based on decoupling control is established;Finally,the decoupling control model and the fault-tolerant control of stator current compensation are verified by the simulation and experiment.The simulation and experiment results show that the method can reduce the torque ripple caused by the stator winding open-circuit fault,and the operation performance of the motor under fault condition is significantly improved.
基金the Ministry of Science and Technology of China under Grant No.2002DEA20014.
文摘Using traditional five-interferogram algorithm to unwrap phase for length measurement, the phase steps must be equal to π/2 exactly, but it is almost impossible to achieve in nanometer positioning technique. Aiming to overcome this defect of traditional five-interferogram algorithm, an improved five-interferogram algorithm is presented. This improved algorithm not only keeps the high accuracy of traditional fiveinterferogram algorithm, but also does not need absolute equal step to unwrap phase. Instead, this algorithm only needs measuring phase-shifting. With the numerical simulation, the improved five-interferogram algorithm shows high accuracy, high reliability, and feasibility in practice. It is very valuable for accurate length measurement with Fizeau interferometer and Fabry-Perot interferometer.
基金Supported in part by the National Natural Science Foundation of China under Grant 52025073in part by the Key Research and Development Program of Jiangsu Province under Grant BE2018107,and in part by the Priority Academic Program Development of Jiangsu Higher Education Institutions.
文摘The main drawbacks of traditional finite set model predictive control are high computational load,large torque ripple,and variable switching frequency.A less complex deadbeat(DB)model predictive current control(MPCC)with improved space vector pulse-width modulation(SVPWM)under a single-phase open-circuit fault is proposed.The proposed method predicts the reference voltage vector in the a-β subspace by employing the deadbeat control principle on the machine predictive model;thus,the exhaustive exploration procedure is avoided to relieve the computational load.To perform the constant switching frequency operation and achieve better steady-state performance,a modified SVPWM strategy is developed with the same conventional structure,which modulates the reference voltage vector.This new approach is based on a redesigned and adjusted post-fault virtual voltage vector space distribution that eliminates the y-axis harmonic components in the x-y subspace and ensures the generation of symmetrical PWM pulses.Meanwhile,the combined merits of the DB,MPCC,and SVPWM methods are realized.To verify the effectiveness of the proposed control scheme,comparative experiments are performed on a five-phase permanent magnet synchronous motor(PMSM)drive system.