Background: Since the greater part of coronary blood flow takes place during the diastolic phase of each cardiac cycle, a time indicator of myocardial perfusion reserve, the ratio of diastolic to systolic duration (D/...Background: Since the greater part of coronary blood flow takes place during the diastolic phase of each cardiac cycle, a time indicator of myocardial perfusion reserve, the ratio of diastolic to systolic duration (D/S ratio), was presented. The objective of this study was to evaluate the accuracy and precision, the biological implication, and the applications of D/S ratio. Methods: Multi-center pragmatic studies evaluating the time indicator of cardiac perfusion reserve were performed. Related experiments, clinical trials, and surveys were conducted at 5 centers. Results: The results showed that the measurement of D/S ratio is both accurate and precise;the mean values of D/S of all of the 3 species studied (human, rabbit, and rat) were greater than 1. These application studies on D/S ratio showed that a close negative correlation existed between D/S ratio and New York Heart Association Functional Classification (NYHA FC) (r = –0.659, p pregnant women with pre-eclampsia and either normal pregnant women or non-pregnant women were significant (p Conclusions: D/S ratio has important biological implication, which is a safe, easy, reliable, and effective indicator, can be used to evaluate fitness levels, served as a pathophysiological marker for screening of cardiovascular disease (CVD), for predicting risk of cardiac events, and for evaluating the severity and prognosis of CVD.展开更多
The application of a novel Particle Swarm Optimization (PSO) method called Fitness Distance Ratio PSO (FDR PSO) algorithm is described in this paper to determine the optimal power dispatch of the Independent Power Pro...The application of a novel Particle Swarm Optimization (PSO) method called Fitness Distance Ratio PSO (FDR PSO) algorithm is described in this paper to determine the optimal power dispatch of the Independent Power Producers (IPP) with linear ramp model and transient stability constraints of the power producers. Generally the power producers must respond quickly to the changes in load and wheeling transactions. Moreover, it becomes necessary for the power producers to reschedule their power generation beyond their power limits to meet vulnerable situations like credible contingency and increase in load conditions. During this process, the ramping cost is incurred if they violate their permissible elastic limits. In this paper, optimal production costs of the power producers are computed with stepwise and piecewise linear ramp rate limits. Transient stability limits of the power producers are also considered as addi-tional rotor angle inequality constraints while solving the Optimal Power Flow (OPF) problem. The proposed algo-rithm is demonstrated on practical 10 bus and 26 bus systems and the results are compared with other optimization methods.展开更多
文摘Background: Since the greater part of coronary blood flow takes place during the diastolic phase of each cardiac cycle, a time indicator of myocardial perfusion reserve, the ratio of diastolic to systolic duration (D/S ratio), was presented. The objective of this study was to evaluate the accuracy and precision, the biological implication, and the applications of D/S ratio. Methods: Multi-center pragmatic studies evaluating the time indicator of cardiac perfusion reserve were performed. Related experiments, clinical trials, and surveys were conducted at 5 centers. Results: The results showed that the measurement of D/S ratio is both accurate and precise;the mean values of D/S of all of the 3 species studied (human, rabbit, and rat) were greater than 1. These application studies on D/S ratio showed that a close negative correlation existed between D/S ratio and New York Heart Association Functional Classification (NYHA FC) (r = –0.659, p pregnant women with pre-eclampsia and either normal pregnant women or non-pregnant women were significant (p Conclusions: D/S ratio has important biological implication, which is a safe, easy, reliable, and effective indicator, can be used to evaluate fitness levels, served as a pathophysiological marker for screening of cardiovascular disease (CVD), for predicting risk of cardiac events, and for evaluating the severity and prognosis of CVD.
文摘The application of a novel Particle Swarm Optimization (PSO) method called Fitness Distance Ratio PSO (FDR PSO) algorithm is described in this paper to determine the optimal power dispatch of the Independent Power Producers (IPP) with linear ramp model and transient stability constraints of the power producers. Generally the power producers must respond quickly to the changes in load and wheeling transactions. Moreover, it becomes necessary for the power producers to reschedule their power generation beyond their power limits to meet vulnerable situations like credible contingency and increase in load conditions. During this process, the ramping cost is incurred if they violate their permissible elastic limits. In this paper, optimal production costs of the power producers are computed with stepwise and piecewise linear ramp rate limits. Transient stability limits of the power producers are also considered as addi-tional rotor angle inequality constraints while solving the Optimal Power Flow (OPF) problem. The proposed algo-rithm is demonstrated on practical 10 bus and 26 bus systems and the results are compared with other optimization methods.