Calibration of line structured light vision system based on camera’s projective center 被引量:7
1
作者 ZHU Ji-gui LI Yan-jun YE Sheng-hua 《光学精密工程》 EI CAS CSCD 北大核心 2005年第5期584-591,共8页
Based on the characteristics of line structured light sensor, a speedy method for the calibration was established. With the coplanar reference target, the spacial pose between camera and optical plane can be calibrate... Based on the characteristics of line structured light sensor, a speedy method for the calibration was established. With the coplanar reference target, the spacial pose between camera and optical plane can be calibrated by using of the camera’s projective center and the light’s information in the camera’s image surface. Without striction to the movement of the coplanar reference target and assistant adjustment equipment, this calibration method can be implemented. This method has been used and decreased the cost of calibration equipment, simplified the calibration procedure, improved calibration efficiency. Using experiment, the sensor can attain relative accuracy about 0.5%, which indicates the rationality and effectivity of this method. 展开更多
关键词 投影中心 线性结构 光传感器 标度 可视性系统