In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building ma...In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building materials used in Malaysia were studied using gamma-ray spectrometer with HPGe detector. Radiological parameters[activity concentration index(ACI), indoor air-absorbed dose rate(D_(in)), annual effective dose(AED_(in)) from external and internal(E_(Rn)), soft tissues(H_(ST)) and lung(H_L), and effective dose equivalent(H_(eff))] were estimated to evaluate radiological hazards due to the use of these building materials: sand, cement, gravel, bricks, tiles, fly ash, white cement, and ceramic raw materials. The measured P, EEC,and E_m vary from 10 to 30%, 0.9 to 22 Bq m^(-3), and 33 to 674 mBq h^(-1) kg^(-1), respectively, while the calculated ACI and AED_(in) vary from 0.1 ± 0.01 to 2.1 ± 0.1 and 0.1 ± 0.01 to 2.4 ± 0.6 mSv y^(-1), respectively. On the other hand, the internal annual effective dose ranges from 0.1 to 1.4 mSv y^(-1). The estimated radiological risk parameters were below the recommended maximum values, and radiological hazards associated with building materials under investigation are therefore negligible.展开更多
基金supported by Universiti Kebangsaan Malaysia and Lynas Advanced Material Plant under Grant Numbers GGPM-2017-084 and ST-2017-012,respectively
文摘In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building materials used in Malaysia were studied using gamma-ray spectrometer with HPGe detector. Radiological parameters[activity concentration index(ACI), indoor air-absorbed dose rate(D_(in)), annual effective dose(AED_(in)) from external and internal(E_(Rn)), soft tissues(H_(ST)) and lung(H_L), and effective dose equivalent(H_(eff))] were estimated to evaluate radiological hazards due to the use of these building materials: sand, cement, gravel, bricks, tiles, fly ash, white cement, and ceramic raw materials. The measured P, EEC,and E_m vary from 10 to 30%, 0.9 to 22 Bq m^(-3), and 33 to 674 mBq h^(-1) kg^(-1), respectively, while the calculated ACI and AED_(in) vary from 0.1 ± 0.01 to 2.1 ± 0.1 and 0.1 ± 0.01 to 2.4 ± 0.6 mSv y^(-1), respectively. On the other hand, the internal annual effective dose ranges from 0.1 to 1.4 mSv y^(-1). The estimated radiological risk parameters were below the recommended maximum values, and radiological hazards associated with building materials under investigation are therefore negligible.