期刊文献+
共找到13篇文章
< 1 >
每页显示 20 50 100
原发性骨质疏松症的诊断和治疗 被引量:15
1
作者 宋轶萱 樊继援 《医学综述》 2008年第3期400-402,共3页
骨质疏松症分为原发性骨质疏松症和继发性骨质疏松症。该病的诊断主要根据病史、骨密度检测、生化检测、影像学检测、骨活检等几个方面进行综合评价。双能量X线吸收法已成为临床常规检查。对患者进行骨质疏松症风险评估的目的是确定骨... 骨质疏松症分为原发性骨质疏松症和继发性骨质疏松症。该病的诊断主要根据病史、骨密度检测、生化检测、影像学检测、骨活检等几个方面进行综合评价。双能量X线吸收法已成为临床常规检查。对患者进行骨质疏松症风险评估的目的是确定骨折的风险因素,以及决定是否应该接受治疗。治疗分为药物和非药物治疗,后者又包括饮食营养和体育锻炼,药物治疗又分为基础性药物治疗和针对性药物治疗。 展开更多
关键词 骨质疏松症 骨折 骨密度 双能量x线吸收法 雌激素
下载PDF
儿童青少年身体脂肪含量和非脂体重的变化分析 被引量:6
2
作者 马军 冯宁 +3 位作者 阿布都艾尼.吾卜力 张世伟 潘勇平 黄永波 《首都公共卫生》 2007年第1期17-24,共8页
目的:分析儿童、青少年身体脂肪含量(FM)和去脂全重(FFM)及其随年龄变化特点及性别差异。方法选择7~15岁体重正常的儿童180名,男、女及每个年龄组各约10名,采用双能 X 线吸收测量法(DEXA)测量身体成分。根据公式 FFMI(kg·m^2,去... 目的:分析儿童、青少年身体脂肪含量(FM)和去脂全重(FFM)及其随年龄变化特点及性别差异。方法选择7~15岁体重正常的儿童180名,男、女及每个年龄组各约10名,采用双能 X 线吸收测量法(DEXA)测量身体成分。根据公式 FFMI(kg·m^2,去脂体重指数)=FFM(kg)/身高~2(m^2)和 FMI(kg·m^2,脂肪含量指数)=FM(kg)/身高~2(m^2),计算 FFMI 和 FMI。结果 7~13岁儿童 FM 及全身脂肪含量占体重百分比随年龄增加而增加,13岁以后有所下降,女高于男。7~15岁男、女儿童 FFMI 随年龄增加而增加,男生青春期 FFMI 增长加速,增加总量为女生的2倍,7~15岁男生 FMI 先增后降,女生则一直呈上升趋势,女生 FMI 增加总量为男生的2倍。男生身高与 FMI 相关性差,11~15岁男生的身高与 FFMI 呈显著性正相关。7~10岁女生身高与 FMI 呈显著性正相关,9~10岁女生的身高与 FFMI 呈显著性正相关(P<0.05)。男、女儿童的 BMI 与 FMI 均呈显著性正相关,男生相关系数大于女生。13~15岁男生和7~15岁女生的BMI 与 FFMI 呈显著性正相关(P<0.05)。结论青春期前后儿童脂肪含量及分布随年龄而变化,男女差异有显著性。男性脂肪向分布加速期发生在12岁,女性在10岁。男生 BMI 随年龄增长而增加,主要为 FFMI 的增加,尤其是青春期男生。女生 BMI 的增长为 FFMI 和 FMI 的同时增加。 展开更多
关键词 身体成分 儿童 双能x线吸收测量法(dexa) 脂肪含量 去脂体重
下载PDF
双能X线吸收法腰椎侧位骨密度测定的临床研究 被引量:6
3
作者 李河北 张颜秋 +4 位作者 苟淑芹 刘春义 张秀华 逯亚平 王茜 《中国骨质疏松杂志》 CAS CSCD 2006年第2期162-163,188,共3页
目的评价双能X线吸收法测定腰椎骨密度时侧位的临床价值。方法178例女性患者(按年龄分组)接受腰椎后前位和侧位骨密度测定,以BMD表示骨密度值,以T值为标准判断骨量正常、骨量减少和骨质疏松,评价腰椎后前位与侧位T值对骨量减少程度的判... 目的评价双能X线吸收法测定腰椎骨密度时侧位的临床价值。方法178例女性患者(按年龄分组)接受腰椎后前位和侧位骨密度测定,以BMD表示骨密度值,以T值为标准判断骨量正常、骨量减少和骨质疏松,评价腰椎后前位与侧位T值对骨量减少程度的判断和骨质疏松诊断的差别。结果①各年龄组患者腰椎后前位BMD值均高于侧位值;②各年龄组患者腰椎后前位及侧位T值对骨量减少程度的判断有显著性差别;③当大于50岁时,腰椎后前位及侧位T值对骨质疏松诊断有显著性差别。结论腰椎侧位对女性患者骨量减少程度的判断和骨质疏松的诊断(>50岁)都有一定临床价值。 展开更多
关键词 双能x线吸收法 骨密度 骨质疏松 腰椎
下载PDF
封蜡骨密度对双能X线骨密度仪与定量CT分析骨矿成份中的矫正研究及应用 被引量:5
4
作者 皮斌 黄俊明 +2 位作者 詹瑶璇 苏素文 衷娟花 《中国医药科学》 2017年第22期221-224,共4页
目的探讨封蜡密度对双能X线骨密度仪与定量CT分析骨矿成分中的矫正及应用。方法取2015年6月~2017年3月医院收治的股骨颈骨折患者20例,患者均行手术治疗,术前进行常规检查,并且分别以DXA、QCT检查双侧髋关节骨密度(P1),测定20例离体股骨... 目的探讨封蜡密度对双能X线骨密度仪与定量CT分析骨矿成分中的矫正及应用。方法取2015年6月~2017年3月医院收治的股骨颈骨折患者20例,患者均行手术治疗,术前进行常规检查,并且分别以DXA、QCT检查双侧髋关节骨密度(P1),测定20例离体股骨头骨密度参数,离体标本初步处理后与参考模量建模,再次进行DXA、QCT扫描(P2)、封蜡后初测质量及排开水体积,获得大体骨密度(P3),制备骨块,复测骨快密度(P4),将获得的标本经过氢氟酸溶解后测定溶液中骨矿成分密度P5。结果 20例骨密度患者DXA测定P1、P2时间点矿骨成分,均低于P3、P4及P5(P<0.05);20例股骨颈骨折患者QCT不同疾病严重程度不同时间点骨密度测定比较差异无统计学意义(P>0.05);DXA检测轻度不同时间点骨密度水平,均低于中级及重级(P<0.05);中级患者不同时间点骨密度,均高于重级(P<0.05);相关性研究显示:封蜡骨密度测定精度与DXA P1、P2成正相关性(P<0.05);与P3、P4及P5呈负相关性(P<0.05)。结论封蜡骨密度对双能X线骨密度仪与定量CT分析骨矿成分中具有良好的矫正作用,具有广泛的应用前景,值得推广应用。 展开更多
关键词 封蜡密度 双能x线骨密度仪 定量CT 骨矿成分 矫正作用
下载PDF
70岁以上老年骨质疏松症DEXA诊断检查部位的选择探讨 被引量:4
5
作者 李玲 陈玉华 +4 位作者 周广举 李娜 任伶俐 杨秋 严宗逊 《川北医学院学报》 CAS 2014年第3期278-280,共3页
目的:探讨70岁以上老年骨质疏松症(osteoporsis,OP)用双能X线骨密度仪(dual energy x-ray absorptiometry,DEXA)诊断检查时,测定部位的不同是否造成漏诊。方法:应用DEXA测定了50例70岁以上临床上有明显的骨质疏松症状者(有症状组)以及50... 目的:探讨70岁以上老年骨质疏松症(osteoporsis,OP)用双能X线骨密度仪(dual energy x-ray absorptiometry,DEXA)诊断检查时,测定部位的不同是否造成漏诊。方法:应用DEXA测定了50例70岁以上临床上有明显的骨质疏松症状者(有症状组)以及50例70岁以上无临床症状的健康体检者(无症状组),对同一检查对象同时测定腰椎(L2-4)正位及左股骨(total)、股骨颈(neck)的骨密度(bone mineral density,BMD),并比较两组不同部位OP的检出率。结果:50例有症状组腰椎(L2-4)测出OP31例(62%),股骨(total)和股骨颈(neck)共测出OP45例(90%)(t=10.638,P<0.01);,50例无症状组腰椎(L2-4)测出OP20例(40%),股骨(total)和股骨颈(neck)共测出OP38例(76%)(t=13.16,P<0.01);结论:70岁以上老年人临床上无论是否合并明显的OP症状,用DEXA诊断检查时,测定部位的不同可能对OP的诊断有影响,髋部OP检出率高于腰椎,最好是同时测定腰椎和髋部的BMD,以防造成漏诊。 展开更多
关键词 骨质疏松症 双能x线骨密度仪 诊断 敏感性
下载PDF
青春期女性骨密度与月经状况的关系 被引量:3
6
作者 赵琳 廖文君 +2 位作者 安丽花 夏琳玲 熊昕 《中国骨质疏松杂志》 CAS CSCD 2008年第3期164-165,共2页
目的了解昆明12~14岁女性骨密度水平并就影响因素进行分析。方法利用双能X线骨密度测定仪测量昆明市某中学98名12~14岁青少年腰椎及髋部骨密度(Bone Mineral Density,BMD),采用问卷调查形式了解与骨密度相关因素。结果女生腰椎、... 目的了解昆明12~14岁女性骨密度水平并就影响因素进行分析。方法利用双能X线骨密度测定仪测量昆明市某中学98名12~14岁青少年腰椎及髋部骨密度(Bone Mineral Density,BMD),采用问卷调查形式了解与骨密度相关因素。结果女生腰椎、股骨颈、大转子骨密度明显高于男生(P〈0.05);月经初潮年龄早的女生骨密度较高(P〈0.05)。结论青春期(12~14岁)阶段女生骨密度较同年龄段男生高,该年龄段女生骨密度与月经初潮年龄有关。 展开更多
关键词 骨密度 女性 双能x线骨密度测定仪
下载PDF
腰椎侧位骨密度测定的应用价值研究 被引量:3
7
作者 冷文川 张美荣 +1 位作者 刘燕 于长隆 《中国运动医学杂志》 CAS CSCD 北大核心 2002年第3期235-238,共4页
目的 :观察应用双能X线测定腰椎椎体骨密度时正位和侧位结果的差别 ,探讨腰椎侧位测定骨密度辅助诊断骨质疏松症的价值。方法 :以 16 6名平均年龄为 6 4 .7岁的老年女性骨质疏松症患者为对象 ,测试其腰椎骨密度值 ,观察不同年龄受试者... 目的 :观察应用双能X线测定腰椎椎体骨密度时正位和侧位结果的差别 ,探讨腰椎侧位测定骨密度辅助诊断骨质疏松症的价值。方法 :以 16 6名平均年龄为 6 4 .7岁的老年女性骨质疏松症患者为对象 ,测试其腰椎骨密度值 ,观察不同年龄受试者腰椎正、侧位骨密度的差别 ,以及由此测试结果得到的诊断骨质疏松结论的差别。结果 :全部受试者的椎体正位骨密度检测均高于侧位(P <0 0 1) ,但在 113名年龄小于 6 5岁的受试者中 ,以此诊断骨质疏松症的结果并无显著性差异(P >0 0 5 ) ;5 3名年龄大于 6 5岁的受试者中 ,根据正、侧位骨密度的变化得到的骨质疏松症诊断出现较大偏差 (P <0 0 5 )。根据正位骨密度测定诊断骨质疏松症约有三分之一漏诊率。结论 :对绝经期骨质疏松患者可以用传统的正位腰椎骨密度测定的方法来诊断 ,不需另作侧位测定 ,对老年性骨质疏松症患者 ,则应加作腰椎侧位骨密度测定 。 展开更多
关键词 骨质疏松 双能x线测定 骨密度 腰椎 诊断
下载PDF
Females Had a Worse T-Score at Lumbar Region and Males Had a Worse T-Score at Femoral Region among Chronic Kidney Disease
8
作者 Hilal Al Kalbani Issa Al Salmi +2 位作者 Fatma Al Rahbi Sumaiya Al Siyabi Suad Hannawi 《Open Journal of Nephrology》 2022年第1期60-74,共15页
Background: To evaluate bone-mineral-density-BMD determined by dual-energy X-ray absorptiometry-DEXA and bone turnover markers in chronic-kidney-disease-CKD patients. Method: An observational-clinical study of all pat... Background: To evaluate bone-mineral-density-BMD determined by dual-energy X-ray absorptiometry-DEXA and bone turnover markers in chronic-kidney-disease-CKD patients. Method: An observational-clinical study of all patients who were scanned by DEXA-scan in 2018. All patients with low-bone-density or osteoporosis-based on World-Health-Organization-WHO definition were included. Results: 505 patients with abnormal-BMD, 87.3% were in early-stage CKD-stage I - II, 8.5% were in CKD-stage III - V and 4.2% did not have renal tests. 95 (18.8%) were male with a mean age of 57.0 years and 410 (81.2%) were females with a mean age of 55.8 years. Patients of ≥65 years had lower T-score than those who were younger than 65 years-old. Among CKD patients, those with late-CKD (stage III - V) had less BMD-measurements and lower T-score than those with early-CKD (stage I - II). A significant positive correlation exists between parathyroid hormone-PTH-level and the lower T-score. Female had a worse T-score at the lumbar-region whereas male had a worse T-score at the femoral-region. There was no significant difference between males and females for the T-score at hip-region. Conclusion: We observed a distribution of abnormal BMD among different age, sex and CKD groups. Measurements of BMD by DEXA might be a useful test to diagnose osteoporosis in CKD patients. Femoral and total hip areas were more affected, however DEXA might not be able to detect osteoporosis in the lumbar area of CKD patients. T-scores are lower in patients with more severe CKD and lower in elderly patients. PTH level is associated proportionally to the degree of bone loss. Early intervention and proper management must be implemented early among CKD patients with multidisciplinary team approach strategy. More studies are needed to determine if DEXA techniques are enough to distinguish the quantity of bone loss between different stages of CKD. 展开更多
关键词 Bone-Mineral-Density-BMD dual-energy x-ray absorptiometry-dexa Chronic-Kidney-Disease-CKD T-SCORE Lumbar Region Femoral Region Gender
下载PDF
不同骨密度测量方法在补钙剂评价中的应用 被引量:1
9
作者 张朋 沈洁 +3 位作者 刘福康 王婷婷 印虹 孙桂菊 《食品科学》 EI CAS CSCD 北大核心 2012年第5期272-274,共3页
目的:评价某补钙为主保健食品增加大鼠骨密度的功效,比较双能X线吸收法(DEXA)与阿基米德定律法在骨密度测量中的应用。方法:参照《保健食品检验与技术评价规范》(2003版")增加骨密度功能检验方法"方案一,将45只断乳Sprague-Da... 目的:评价某补钙为主保健食品增加大鼠骨密度的功效,比较双能X线吸收法(DEXA)与阿基米德定律法在骨密度测量中的应用。方法:参照《保健食品检验与技术评价规范》(2003版")增加骨密度功能检验方法"方案一,将45只断乳Sprague-Dawley大鼠按体质量随机分为碳酸钙对照组、低钙对照组和保健品低、中、高剂量组(0.17、0.33、1.00g/kg),对某保健食品进行评价。结果:保健品高剂量组及碳酸钙对照组大鼠在钙表观吸收率、质量增加量、骨密度及骨钙含量上明显高于低钙对照组(P<0.05)。除骨密度外,保健品高剂量组同碳酸钙对照组相比各指标差异不显著;DEXA法与阿基米德定律法所测骨密度结果相关性较好。结论:该保健食品对大鼠有增加骨密度作用;DEXA法与阿基米德定律法均可用于动物实验中骨密度的测定。 展开更多
关键词 大鼠 骨密度x线吸收法 阿基米德定律
下载PDF
陕西地区股骨上段骨折风险阈值研究
10
作者 朱文艺 王坤正 +3 位作者 刘凯 王瑞 洪刚 郭子城 《中国骨质疏松杂志》 CAS CSCD 北大核心 2013年第7期665-669,共5页
目的找出最佳的预测老年人群股骨上段骨折风险的方法。方法利用双能X线吸收仪(DEXA)和其他工具,测量30具尸体骨右侧股骨上段的骨密度、几何形态以及股骨上段极限强度。然后,通过物理公式分析摔倒时股骨上段的受力情况。结果 (1)女性各... 目的找出最佳的预测老年人群股骨上段骨折风险的方法。方法利用双能X线吸收仪(DEXA)和其他工具,测量30具尸体骨右侧股骨上段的骨密度、几何形态以及股骨上段极限强度。然后,通过物理公式分析摔倒时股骨上段的受力情况。结果 (1)女性各项参数多数低于男性。(2)股骨颈骨密度与股骨上段载荷之间的相关性最佳(r2=0.807),推导出预测股骨上段骨折风险回归方程。(3)股骨颈宽度与股骨上段极限强度的相关性较好。(4)推导出骨折风险阈值。结论 (1)陕西地区老年人股骨上段骨折发生率较低,与体型小导致摔倒时的暴力低有关。(2)股骨颈骨密度为较好的骨折风险预测指标。与几何形态结合可提高预测能力。(3)通过骨折风险阈值公式早期预防骨质疏松骨折的发生。 展开更多
关键词 股骨上段载荷 骨密度(BMD) 股骨上段几何形态 双能x线吸收测定(dexa) 股骨上段骨折
下载PDF
有领与无领股骨柄假体周围早期骨丢失的临床研究
11
作者 季卫平 王小玲 +2 位作者 麻妙群 兰俊 李浩 《中国中医骨伤科杂志》 CAS 2012年第10期12-14,17,共4页
目的:观察抗骨质疏松药及有领与无领股骨柄对全髋关节置换术后股骨侧假体周围骨密度的影响。方法:随机对80例行非骨水泥型人工髋关节假体置换患者,分成有领治疗组(1组)、对照组(2组);无领治疗组(3组)、对照组(4组),每组20例。1、3组均... 目的:观察抗骨质疏松药及有领与无领股骨柄对全髋关节置换术后股骨侧假体周围骨密度的影响。方法:随机对80例行非骨水泥型人工髋关节假体置换患者,分成有领治疗组(1组)、对照组(2组);无领治疗组(3组)、对照组(4组),每组20例。1、3组均给予福善美+钙尔奇D3+仙灵骨葆胶囊口服,2、4组仅给口服钙尔奇D3片;各组分别于术后12d、3月、6月应用双能X线骨密度仪(DEXA)测量THA术后股骨柄假体周围的大转子(测1区)、离远端股骨柄0.5~1.0cm处股骨干(测2区)骨密度,同时测量健侧相同部位骨密度。结果:在12d和3月,1、2组相比差异无统计学意义(P>0.001)。在术后6月时,1、2组相比差异均有统计学意义(P<0.001),健侧更明显一些,说明用药能显著减少骨量流失。3、4组不论是患侧还是健侧,在术后6月时,测1区和测2区两组相比差异均有统计学意义(P<0.001)。1、3组在术后3m及6m时,不论是患侧还是健侧,各测量区骨密度比较差异均无统计学意义(P>0.05)。结论:1.使用有领柄还是无领柄对假体周围骨密度变化影响不大。2.福善美+钙尔奇D3+仙灵骨葆胶囊可预防假体周围早期骨丢失。 展开更多
关键词 非骨水泥假体 阿仑膦酸钠 骨密度 双能x线骨密度仪 临床研究
原文传递
高原地区健康中老年人椎体骨量CT定量评价
12
作者 张恒 毛泽庆 +3 位作者 马军 马娅琼 牛晶晶 徐香玖 《甘肃中医药大学学报》 2020年第1期130-133,共4页
目的评价高原地区健康中老年人椎体骨量的变化规律。方法对130例50岁以上健康体检中老年人采用双能X射线骨密度仪(DEXA)测量椎体骨密度(BMD)值再行胸部多层螺旋CT(MSCT)扫描,测量T10-12及L1椎体CT值对2种方法的测量值进行相关性分析。... 目的评价高原地区健康中老年人椎体骨量的变化规律。方法对130例50岁以上健康体检中老年人采用双能X射线骨密度仪(DEXA)测量椎体骨密度(BMD)值再行胸部多层螺旋CT(MSCT)扫描,测量T10-12及L1椎体CT值对2种方法的测量值进行相关性分析。将所有中老年人按年龄分为50~<55岁、55~<65岁、65~<87岁3组,比较各组间及同年龄组不同性别间CT值。结果50~<55岁、55~<65岁组男、女T10-12及L1椎体CT值比较差异均无统计学意义(P>0.05),65~<87岁组女性T10-12及L1椎体CT值均低于男性差异有统计学意义(P<0.05);与50~<55岁组及55~<65岁组比较;65~<87岁组男、女T10-12及L1椎体CT值均明显降低差异有统计学意义(P<0.05或P<0.01)。BMD值与T10-12及L1椎体CT值呈显著正相关(P<0.01)相关系数r分别为0.630,0.585。结论中老年人椎体BMD随年龄增大而降低,年龄越大男、女性之间的差异越明显;MSCT是一种简便、价廉且能较为准确评价椎体BMD的方法。 展开更多
关键词 高原地区 椎体骨密度 双能x射线骨密度仪 多层螺旋CT 定量评价
原文传递
全髋关节置换术后假体周围骨密度动态观察 被引量:8
13
作者 沈霖 D.Sabo V.Ewerbeck 《中国中医骨伤科杂志》 CAS 2001年第3期1-4,共4页
目的 :运用双能 X线骨密度仪动态观察全髋关节置换术后假体周围骨密度 ( BMD)变化。方法 :对4 1例全髋关节置换术后患者股骨及髋臼假体周围 BMD进行 1 2个月的动态观察 ,并与 2 3例术后 5年以上的患者比较。其中股骨柄假体周围 BMD按 Gr... 目的 :运用双能 X线骨密度仪动态观察全髋关节置换术后假体周围骨密度 ( BMD)变化。方法 :对4 1例全髋关节置换术后患者股骨及髋臼假体周围 BMD进行 1 2个月的动态观察 ,并与 2 3例术后 5年以上的患者比较。其中股骨柄假体周围 BMD按 Gruen法分为 7个兴趣区 ( R1 -7)分析 ;髋臼假体周围按 De Lee和Charnley法分为 3个兴趣区 ( R - )分析。并将各时相 BMD值与术后一周内测值比较。结果 :股骨柄假体周围 BMD平均值 ( NETAVG I)在术后 6个月降至 92 .1 2 % ,术后 1 2月又上升至 94 .0 8%。其中以股骨柄近端周围松质骨 BMD下降最为明显。近端外侧 ( R1 )为 83.78% ,内侧 ( R7)为 88.31 %。髋臼假体周围 BMD( NE-TAVG )在术后 6个月平均下降至 78.2 8% ,术后 1 2月上升至 85 .2 1 %。以臼杯假体内侧 ( R )失骨量最多 ,降至 70 .2 2 %。术后 5年患者股骨柄假体周围 BMD平均值与 1 2月组比较无明显差异 ;但髋臼杯周围下降明显 ( P<0 .0 5 )。结论 :DEXA是监测 THA假体周围 BMD变化的有效方法。全髋关节置换术后假体周围的松质骨的骨吸收、丢失是导致假体松动的重要原因 ;而密质骨相对失骨量较少。 展开更多
关键词 骨密度 双能x线骨密度仪 全髋关节置换术 骨丢失
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部