In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building ma...In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building materials used in Malaysia were studied using gamma-ray spectrometer with HPGe detector. Radiological parameters[activity concentration index(ACI), indoor air-absorbed dose rate(D_(in)), annual effective dose(AED_(in)) from external and internal(E_(Rn)), soft tissues(H_(ST)) and lung(H_L), and effective dose equivalent(H_(eff))] were estimated to evaluate radiological hazards due to the use of these building materials: sand, cement, gravel, bricks, tiles, fly ash, white cement, and ceramic raw materials. The measured P, EEC,and E_m vary from 10 to 30%, 0.9 to 22 Bq m^(-3), and 33 to 674 mBq h^(-1) kg^(-1), respectively, while the calculated ACI and AED_(in) vary from 0.1 ± 0.01 to 2.1 ± 0.1 and 0.1 ± 0.01 to 2.4 ± 0.6 mSv y^(-1), respectively. On the other hand, the internal annual effective dose ranges from 0.1 to 1.4 mSv y^(-1). The estimated radiological risk parameters were below the recommended maximum values, and radiological hazards associated with building materials under investigation are therefore negligible.展开更多
We report helium ion irradiation experiments for a new type of dispersion-strengthened NiMo-Y_(2)O_(3)alloy with three different irradiation doses and varying irradiation dose rates at 750℃to evaluate its helium-indu...We report helium ion irradiation experiments for a new type of dispersion-strengthened NiMo-Y_(2)O_(3)alloy with three different irradiation doses and varying irradiation dose rates at 750℃to evaluate its helium-induced damage behavior.Transmission electron microscopy was used to reveal the evolution of helium bubbles after irradiation.The experimental results show that with increasing ion dose,the number density of helium bubbles increases continuously.However,the mean size of helium bubbles first increases and then decreases,mainly due to the varied ion dose rates.The volume fractions of helium bubbles in the three investigated samples after irradiation are 0.15%,0.32%,and 0.27%,which are lower than that of the Hastelloy N alloy(0.58%)after similar irradiation conditions.This indicates that the NiMo-Y_(2)O_(3)alloy exhibits better helium-induced-swelling resistance than the Hastelloy N alloy,highlighting its potential applicability to MSRs,from the perspective of irradiation performance.展开更多
Aim: The simultaneous irradiation of target volumes of different total dose levels using intensity modulated radiotherapy leads to reduced doses per fraction and longer treatment times in target volumes of 2nd?to 4th?...Aim: The simultaneous irradiation of target volumes of different total dose levels using intensity modulated radiotherapy leads to reduced doses per fraction and longer treatment times in target volumes of 2nd?to 4th?order. Does the thereby caused reduced biological effectiveness induce an increased recurrence risk? The current work deals with the problem of recurrences of patients with head and neck carcinomas treated either with an intensitiy (IMRT) or with a volumetric modulated (VMAT) irradiation technique. Methods: From October 2002 to September 2014, 699 patients with carcinomas of the head and neck were irradiated using IMRT or VMAT. The median follow up of the patients was 21.9 months (2 to 145 months). Primary tumor regions (1st?order target volume) of 565 patients were treated with doses per fraction of 2 Gy. Accordingly, further 133 target volumes of the primary tumor received reduced doses per fraction. In 1 patient, the lymphatic drainage was treated solely without irradiation of the primary region. For the lympatic drainage, 854 1st?order target volumes were treated with a dose per fraction of 2 Gy. Reduced doses per fraction were applied to further 1780 target volumes. Results: 54 of 699 patients developed a recurrence in the primary tumor region after radio-(chemo) therapy, 4 patients developed a recurrence of the primary tumor and a unilateral recurrence of the lymphatic drainage, 2 patients a recurrence of the primary tumor and a bilateral lymph node recurrence. 18 patients showed an isolated unilateral recurrence and additionally 2 patients a bilateral recurrence of the lymphatic drainage. 619 patients stayed recurrence free. In primary tumor regions, receiving a dose per fraction of 2 Gy 55 patients (9.7%) developed a recurrence, whereas in target volumes receiving a reduced dose per fraction 5 patients (3.8%) developed a recurrence (p < 0.001). In lympatic drainage target volumes receiving a dose per fraction of 2 Gy, 25 target volumes (2.9%) developed a recurrence, whereas in target volumes 展开更多
基金supported by Universiti Kebangsaan Malaysia and Lynas Advanced Material Plant under Grant Numbers GGPM-2017-084 and ST-2017-012,respectively
文摘In this study, the activity concentrations of ^(226)Ra,^(232)Th,^(222)Rn, and ^(40)K, emanation fractions(P),equilibrium equivalent concentration(EEC), and mass exhalation rates(E_m) of radon released from building materials used in Malaysia were studied using gamma-ray spectrometer with HPGe detector. Radiological parameters[activity concentration index(ACI), indoor air-absorbed dose rate(D_(in)), annual effective dose(AED_(in)) from external and internal(E_(Rn)), soft tissues(H_(ST)) and lung(H_L), and effective dose equivalent(H_(eff))] were estimated to evaluate radiological hazards due to the use of these building materials: sand, cement, gravel, bricks, tiles, fly ash, white cement, and ceramic raw materials. The measured P, EEC,and E_m vary from 10 to 30%, 0.9 to 22 Bq m^(-3), and 33 to 674 mBq h^(-1) kg^(-1), respectively, while the calculated ACI and AED_(in) vary from 0.1 ± 0.01 to 2.1 ± 0.1 and 0.1 ± 0.01 to 2.4 ± 0.6 mSv y^(-1), respectively. On the other hand, the internal annual effective dose ranges from 0.1 to 1.4 mSv y^(-1). The estimated radiological risk parameters were below the recommended maximum values, and radiological hazards associated with building materials under investigation are therefore negligible.
基金supported by the National Natural Science Foundation of China(Grant Nos.12022515,11975304,and 91126012)the Youth Innovation Promotion Association,CAS(Grant No.202063)。
文摘We report helium ion irradiation experiments for a new type of dispersion-strengthened NiMo-Y_(2)O_(3)alloy with three different irradiation doses and varying irradiation dose rates at 750℃to evaluate its helium-induced damage behavior.Transmission electron microscopy was used to reveal the evolution of helium bubbles after irradiation.The experimental results show that with increasing ion dose,the number density of helium bubbles increases continuously.However,the mean size of helium bubbles first increases and then decreases,mainly due to the varied ion dose rates.The volume fractions of helium bubbles in the three investigated samples after irradiation are 0.15%,0.32%,and 0.27%,which are lower than that of the Hastelloy N alloy(0.58%)after similar irradiation conditions.This indicates that the NiMo-Y_(2)O_(3)alloy exhibits better helium-induced-swelling resistance than the Hastelloy N alloy,highlighting its potential applicability to MSRs,from the perspective of irradiation performance.
文摘Aim: The simultaneous irradiation of target volumes of different total dose levels using intensity modulated radiotherapy leads to reduced doses per fraction and longer treatment times in target volumes of 2nd?to 4th?order. Does the thereby caused reduced biological effectiveness induce an increased recurrence risk? The current work deals with the problem of recurrences of patients with head and neck carcinomas treated either with an intensitiy (IMRT) or with a volumetric modulated (VMAT) irradiation technique. Methods: From October 2002 to September 2014, 699 patients with carcinomas of the head and neck were irradiated using IMRT or VMAT. The median follow up of the patients was 21.9 months (2 to 145 months). Primary tumor regions (1st?order target volume) of 565 patients were treated with doses per fraction of 2 Gy. Accordingly, further 133 target volumes of the primary tumor received reduced doses per fraction. In 1 patient, the lymphatic drainage was treated solely without irradiation of the primary region. For the lympatic drainage, 854 1st?order target volumes were treated with a dose per fraction of 2 Gy. Reduced doses per fraction were applied to further 1780 target volumes. Results: 54 of 699 patients developed a recurrence in the primary tumor region after radio-(chemo) therapy, 4 patients developed a recurrence of the primary tumor and a unilateral recurrence of the lymphatic drainage, 2 patients a recurrence of the primary tumor and a bilateral lymph node recurrence. 18 patients showed an isolated unilateral recurrence and additionally 2 patients a bilateral recurrence of the lymphatic drainage. 619 patients stayed recurrence free. In primary tumor regions, receiving a dose per fraction of 2 Gy 55 patients (9.7%) developed a recurrence, whereas in target volumes receiving a reduced dose per fraction 5 patients (3.8%) developed a recurrence (p < 0.001). In lympatic drainage target volumes receiving a dose per fraction of 2 Gy, 25 target volumes (2.9%) developed a recurrence, whereas in target volumes