In the voltage source converter based high-voltage direct current(VSC-HVDC)grids,fast and reliable protections are the key technologies.The traditional protection schemes are easily affected by fault resistance,line d...In the voltage source converter based high-voltage direct current(VSC-HVDC)grids,fast and reliable protections are the key technologies.The traditional protection schemes are easily affected by fault resistance,line distributed capacitance,etc.Meanwhile,the influence of fault current limiting strategy(FCLS)has not been fully considered.In this paper,the fault characteristics under FCLS and the feasibility of traditional travelling wave protections are analyzed.To improve the reliability and sensibility,a similarity comparison based pilot protection scheme is proposed,which focuses on the relationship between the fault characteristics and the state of the protected transmission line,with the establishment of a precise frequencydependent transmission line model.The criteria based on the similarity comparison calculated by cross-wavelet can identify the fault effectively.Meanwhile,the protection scheme can also endure the influence of error synchronization.Finally,the protection performance is verified in the PSCAD/EMTDC under different fault conditions.展开更多
Offshore wind energy is an important part of clean energy,and the adoption of wind energy to generate electricity will contribute to the implementation of the carbon peaking and carbon neutrality goals.The combination...Offshore wind energy is an important part of clean energy,and the adoption of wind energy to generate electricity will contribute to the implementation of the carbon peaking and carbon neutrality goals.The combination of the fractional frequency transmission system(FFTS) and the direct-drive wind turbine generator will be beneficial to the development of the offshore wind power industry.The use of fractional frequency in FFTS is beneficial to the transmission of electrical energy,but it will also lead to an increase in the volume and weight of the generator,which is unfavorable for wind power generation.Improving the torque density of the generator can effectively reduce the volume of the generators.The vernier permanent magnet machine(VPM) operates on the magnetic flux modulation principle and has the merits of high torque density.In the field of electric machines,the vernier machine based on the principle of magnetic flux modulation has been proved its feasibility to reduce the volume and weight.However,in the field of low-speed direct-drive machines for high-power fractional frequency power generation,there are still few related researches.Therefore,this paper studies the application of magnetic flux modulation in fractional frequency and high-power direct-drive wind turbine generators,mainly analyzes the influence of different pole ratios and different pole pairs on the generator,and draws some conclusions to provide reference for the design of wind turbine generators.展开更多
When a renewable energy station(RES)connects to the rectifier station(RS)of a modular multilevel converterbased high-voltage direct current(MMC-HVDC)system,the voltage at the point of common coupling(PCC)is determined...When a renewable energy station(RES)connects to the rectifier station(RS)of a modular multilevel converterbased high-voltage direct current(MMC-HVDC)system,the voltage at the point of common coupling(PCC)is determined by RS control methods.For example,RS control may become saturated under fault,and causes the RS to change from an equivalent voltage source to an equivalent current source,making fault analysis more complicated.In addition,the grid code of the fault ride-through(FRT)requires the RES to output current according to its terminal voltage.This changes the fault point voltage and leads to RES voltage regulation and current redistribution,resulting in fault response interactions.To address these issues,this study describes how an MMC-integrated system has five operation modes and three common characteristics under the duration of the fault.The study also reveals several instances of RS performance degradation such as AC voltage loop saturation,and shows that RS power reversal can be significantly improved.An enhanced AC FRT control method is proposed to achieve controllable PCC voltage and continuous power transmission by actively reducing the PCC voltage amplitude.The robustness of the method is theoretically proven under parameter variation and operation mode switching.Finally,the feasibility of the proposed method is verified through MATLAB/Simulink results.展开更多
基金supported by National Natural Science Foundation of ChinaState Grid Joint Fund for Smart Grid(No.U2066210)National Natural Science Foundation of China(No.52007003)。
文摘In the voltage source converter based high-voltage direct current(VSC-HVDC)grids,fast and reliable protections are the key technologies.The traditional protection schemes are easily affected by fault resistance,line distributed capacitance,etc.Meanwhile,the influence of fault current limiting strategy(FCLS)has not been fully considered.In this paper,the fault characteristics under FCLS and the feasibility of traditional travelling wave protections are analyzed.To improve the reliability and sensibility,a similarity comparison based pilot protection scheme is proposed,which focuses on the relationship between the fault characteristics and the state of the protected transmission line,with the establishment of a precise frequencydependent transmission line model.The criteria based on the similarity comparison calculated by cross-wavelet can identify the fault effectively.Meanwhile,the protection scheme can also endure the influence of error synchronization.Finally,the protection performance is verified in the PSCAD/EMTDC under different fault conditions.
基金supported by the Science and Technology Foundation of SGCC (5500-202099509A-0-0-00)“Research on Fractional Frequency Transmission Technology for Largely Enhancing Transmission Capacity and Development of Its Key Devices”。
文摘Offshore wind energy is an important part of clean energy,and the adoption of wind energy to generate electricity will contribute to the implementation of the carbon peaking and carbon neutrality goals.The combination of the fractional frequency transmission system(FFTS) and the direct-drive wind turbine generator will be beneficial to the development of the offshore wind power industry.The use of fractional frequency in FFTS is beneficial to the transmission of electrical energy,but it will also lead to an increase in the volume and weight of the generator,which is unfavorable for wind power generation.Improving the torque density of the generator can effectively reduce the volume of the generators.The vernier permanent magnet machine(VPM) operates on the magnetic flux modulation principle and has the merits of high torque density.In the field of electric machines,the vernier machine based on the principle of magnetic flux modulation has been proved its feasibility to reduce the volume and weight.However,in the field of low-speed direct-drive machines for high-power fractional frequency power generation,there are still few related researches.Therefore,this paper studies the application of magnetic flux modulation in fractional frequency and high-power direct-drive wind turbine generators,mainly analyzes the influence of different pole ratios and different pole pairs on the generator,and draws some conclusions to provide reference for the design of wind turbine generators.
基金supported in part by the National Key Research and Development Program of China(No.2020YFF0305800)State Grid Science Technology Project(No.520201210025)。
文摘When a renewable energy station(RES)connects to the rectifier station(RS)of a modular multilevel converterbased high-voltage direct current(MMC-HVDC)system,the voltage at the point of common coupling(PCC)is determined by RS control methods.For example,RS control may become saturated under fault,and causes the RS to change from an equivalent voltage source to an equivalent current source,making fault analysis more complicated.In addition,the grid code of the fault ride-through(FRT)requires the RES to output current according to its terminal voltage.This changes the fault point voltage and leads to RES voltage regulation and current redistribution,resulting in fault response interactions.To address these issues,this study describes how an MMC-integrated system has five operation modes and three common characteristics under the duration of the fault.The study also reveals several instances of RS performance degradation such as AC voltage loop saturation,and shows that RS power reversal can be significantly improved.An enhanced AC FRT control method is proposed to achieve controllable PCC voltage and continuous power transmission by actively reducing the PCC voltage amplitude.The robustness of the method is theoretically proven under parameter variation and operation mode switching.Finally,the feasibility of the proposed method is verified through MATLAB/Simulink results.