Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and...Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and analyze their application values.Methods:Fifty patients with suspected occupational noise-induced hearing loss were randomly selected from the Department of Otolaryngology at the hospital as the research target.The collection period for the research cases spanned from January 2022 to November 2023,and all patients had a history of noise exposure.The DIN test and HHIA-S were used for hearing examinations,with clinical,comprehensive diagnosis serving as the gold standard to study their diagnostic performance.Results:The compliance rate of the DIN test was 88.00%,the HHIA-S’s compliance rate was 80.00%,and the combined compliance rate was 94.00%.The compliance rate of the DIN test and the combined compliance rates of the patients were statistically significant compared to the clinical gold standard data(P<0.05),while there was no difference between the compliance rate of the HHIA-S and the gold standard(P>0.05).The data shows that the sensitivity of the combined diagnosis is significantly higher than the sensitivity data of the DIN test and HHIA-S examination alone(P<0.05).Its specificity is 100.00%,and the accuracy data of the joint diagnosis in the degree were higher than those of the DIN test alone(P>0.05)and the HHIA-S alone(P<0.05).Conclusion:For patients with occupational noise-induced hearing loss,the joint evaluation of the DIN test and HHIA-S can significantly improve their diagnostic value with high sensitivity and accuracy.展开更多
Zinc ion batteries are considered as potential energy storage devices due to their advantages of low-cost,high-safety,and high theoretical capacity.However,dendrite growth and chemical corrosion occurring on Zn anode ...Zinc ion batteries are considered as potential energy storage devices due to their advantages of low-cost,high-safety,and high theoretical capacity.However,dendrite growth and chemical corrosion occurring on Zn anode limit their commercialization.These problems can be tackled through the optimization of the electrolyte.However,the screening of electrolyte additives using normal electrochemical methods is time-consuming and labor-intensive.Herein,a fast and simple method based on the digital holography is developed.It can realize the in situ monitoring of electrode/electrolyte interface and provide direct information concerning ion concentration evolution of the diffusion layer.It is effective and time-saving in estimating the homogeneity of the deposition layer and predicting the tendency of dendrite growth,thus able to value the applicability of electrolyte additives.The feasibility of this method is further validated by the forecast and evaluation of thioacetamide additive.Based on systematic characterization,it is proved that the introduction of thioacetamide can not only regulate the interficial ion flux to induce dendrite-free Zn deposition,but also construct adsorption molecule layers to inhibit side reactions of Zn anode.Being easy to operate,capable of in situ observation,and able to endure harsh conditions,digital holography method will be a promising approach for the interfacial investigation of other battery systems.展开更多
文摘Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and analyze their application values.Methods:Fifty patients with suspected occupational noise-induced hearing loss were randomly selected from the Department of Otolaryngology at the hospital as the research target.The collection period for the research cases spanned from January 2022 to November 2023,and all patients had a history of noise exposure.The DIN test and HHIA-S were used for hearing examinations,with clinical,comprehensive diagnosis serving as the gold standard to study their diagnostic performance.Results:The compliance rate of the DIN test was 88.00%,the HHIA-S’s compliance rate was 80.00%,and the combined compliance rate was 94.00%.The compliance rate of the DIN test and the combined compliance rates of the patients were statistically significant compared to the clinical gold standard data(P<0.05),while there was no difference between the compliance rate of the HHIA-S and the gold standard(P>0.05).The data shows that the sensitivity of the combined diagnosis is significantly higher than the sensitivity data of the DIN test and HHIA-S examination alone(P<0.05).Its specificity is 100.00%,and the accuracy data of the joint diagnosis in the degree were higher than those of the DIN test alone(P>0.05)and the HHIA-S alone(P<0.05).Conclusion:For patients with occupational noise-induced hearing loss,the joint evaluation of the DIN test and HHIA-S can significantly improve their diagnostic value with high sensitivity and accuracy.
基金supported by the National Natural Science Foundation of China(No.22075115)Natural Science Foundation of Jiangsu Province(No.BK20211352)+2 种基金Joint Funds of the National Natural Science Foundation of China(No.U2141201)Natural Science Foundation(No.22KJA430005)of Jiangsu Education Committee of ChinaPostgraduate Research and Practice Innovation Program of Jiangsu Normal University(No.2021XKT0296).
文摘Zinc ion batteries are considered as potential energy storage devices due to their advantages of low-cost,high-safety,and high theoretical capacity.However,dendrite growth and chemical corrosion occurring on Zn anode limit their commercialization.These problems can be tackled through the optimization of the electrolyte.However,the screening of electrolyte additives using normal electrochemical methods is time-consuming and labor-intensive.Herein,a fast and simple method based on the digital holography is developed.It can realize the in situ monitoring of electrode/electrolyte interface and provide direct information concerning ion concentration evolution of the diffusion layer.It is effective and time-saving in estimating the homogeneity of the deposition layer and predicting the tendency of dendrite growth,thus able to value the applicability of electrolyte additives.The feasibility of this method is further validated by the forecast and evaluation of thioacetamide additive.Based on systematic characterization,it is proved that the introduction of thioacetamide can not only regulate the interficial ion flux to induce dendrite-free Zn deposition,but also construct adsorption molecule layers to inhibit side reactions of Zn anode.Being easy to operate,capable of in situ observation,and able to endure harsh conditions,digital holography method will be a promising approach for the interfacial investigation of other battery systems.