An innovative strategy for optimal nonlinear feedback control of linear or nonlinear stochastic dynamic systems is proposed based on the stochastic averaging method for quasi-Hamiltonian systems and stochastic dynamic...An innovative strategy for optimal nonlinear feedback control of linear or nonlinear stochastic dynamic systems is proposed based on the stochastic averaging method for quasi-Hamiltonian systems and stochastic dynamic programming principle. Feedback control forces of a system are divided into conservative parts and dissipative parts. The conservative parts are so selected that the energy distribution in the controlled system is as requested as possible. Then the response of the system with known conservative control forces is reduced to a controlled diffusion process by using the stochastic averaging method. The dissipative parts of control forces are obtained from solving the stochastic dynamic programming equation.展开更多
AIMTo describe magnetic resonance (MR) imaging features of pancreatic neuroendocrine neoplasms (PanNENs) according to their grade and tumor-nodes-metastases stage by comparing them to histopathology and to determine t...AIMTo describe magnetic resonance (MR) imaging features of pancreatic neuroendocrine neoplasms (PanNENs) according to their grade and tumor-nodes-metastases stage by comparing them to histopathology and to determine the accuracy of MR imaging features in predicting their biological behavior.METHODSThis study was approved by our institutional review board; requirement for informed patient consent was waived due to the retrospective nature of the study. Preoperative MR examinations of 55 PanNEN patients (29 men, 26 women; mean age of 57.6 years, range 21-83 years) performed between June 2013 and December 2015 were reviewed. Qualitative and quantitative features were compared between tumor grades and stages determined by histopathological analysis.RESULTSIll defined margins were more common in G2-3 and stage III-IV PanNENs than in G1 and low-stage tumors (P < 0.001); this feature had high specificity in the identification of G2-3 and stage III-IV tumors (90.3% and 96%, 95%CI: 73.1-97.5 and 77.7-99.8). The mean apparent diffusion coefficient value was significantly lower in G2-3 and stage III-IV lesions compared to well differentiated and low-stage tumors (1.09 × 10<sup>-3</sup> mm<sup>2</sup>/s vs 1.45 × 10<sup>-3</sup> mm<sup>2</sup>/s and 1.10 × 10<sup>-3</sup> mm<sup>2</sup>/s vs 1.53 × 10<sup>-3</sup> mm<sup>2</sup>/s, P = 0.003 and 0.001). Receiving operator characteristic analysis determined optimal cut-offs of 1.21 and 1.28 × 10<sup>-3</sup> mm<sup>2</sup>/s for the identification of G2-3 and stage III-IV tumors, with sensitivity and specificity values of 70.8/80.7% and 64.5/64% (95%CI: 48.7-86.6/60-92.7 and 45.4-80.2/42.6-81.3).CONCLUSIONMR features of PanNENs vary according to their grade of differentiation and their stage at diagnosis and could predict the biological behavior of these tumors.展开更多
The equivalence between multilayered barriers regarding diffusion and adsorption was studied. The bottom boundary of the liner system is defined by assuming concentration continuous and flux continuous conditions of t...The equivalence between multilayered barriers regarding diffusion and adsorption was studied. The bottom boundary of the liner system is defined by assuming concentration continuous and flux continuous conditions of the contaminant between the bottom liner layer and the underlying soil. Five different liner systems were compared in terms of solute breakthrough time. The results of the analysis showed that breakthrough time of the hydrophobic organic compounds for a 2-meter-thick compacted clay liner (CCL) could be 3-4 orders of magnitude is greater than the breakthrough time for a geosynthetic clay liner (GCL) composite liner. The GM/GCL and GM/CCL composite liner systems provide a better diffusion barrier for the hydrophilic organic compounds than that for the hydrophobic compounds due to their different Henry's coefficient. The calculated breakthrough times of the organic contaminants for the Chinese standard liner systems were found to be generally greater than those for the GCL alternatives, for the specific conditions examined. If the distribution coefficient increases to 2.8 for the hydrophobic compounds or 1.0 for the hydrophilic compounds, the thickness of the attenuation layer needed to achieve the same breakthrough time as the standard liner systems can be reduced by a factor of about 1.9-2.4. As far as diffusive and adsorption contaminant transport are concerned, GM or GCL is less effective than CCL.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No. 19672054)Cao Guangbiao High Science and Technology Development Foundation of Zhejiang University.
文摘An innovative strategy for optimal nonlinear feedback control of linear or nonlinear stochastic dynamic systems is proposed based on the stochastic averaging method for quasi-Hamiltonian systems and stochastic dynamic programming principle. Feedback control forces of a system are divided into conservative parts and dissipative parts. The conservative parts are so selected that the energy distribution in the controlled system is as requested as possible. Then the response of the system with known conservative control forces is reduced to a controlled diffusion process by using the stochastic averaging method. The dissipative parts of control forces are obtained from solving the stochastic dynamic programming equation.
文摘AIMTo describe magnetic resonance (MR) imaging features of pancreatic neuroendocrine neoplasms (PanNENs) according to their grade and tumor-nodes-metastases stage by comparing them to histopathology and to determine the accuracy of MR imaging features in predicting their biological behavior.METHODSThis study was approved by our institutional review board; requirement for informed patient consent was waived due to the retrospective nature of the study. Preoperative MR examinations of 55 PanNEN patients (29 men, 26 women; mean age of 57.6 years, range 21-83 years) performed between June 2013 and December 2015 were reviewed. Qualitative and quantitative features were compared between tumor grades and stages determined by histopathological analysis.RESULTSIll defined margins were more common in G2-3 and stage III-IV PanNENs than in G1 and low-stage tumors (P < 0.001); this feature had high specificity in the identification of G2-3 and stage III-IV tumors (90.3% and 96%, 95%CI: 73.1-97.5 and 77.7-99.8). The mean apparent diffusion coefficient value was significantly lower in G2-3 and stage III-IV lesions compared to well differentiated and low-stage tumors (1.09 × 10<sup>-3</sup> mm<sup>2</sup>/s vs 1.45 × 10<sup>-3</sup> mm<sup>2</sup>/s and 1.10 × 10<sup>-3</sup> mm<sup>2</sup>/s vs 1.53 × 10<sup>-3</sup> mm<sup>2</sup>/s, P = 0.003 and 0.001). Receiving operator characteristic analysis determined optimal cut-offs of 1.21 and 1.28 × 10<sup>-3</sup> mm<sup>2</sup>/s for the identification of G2-3 and stage III-IV tumors, with sensitivity and specificity values of 70.8/80.7% and 64.5/64% (95%CI: 48.7-86.6/60-92.7 and 45.4-80.2/42.6-81.3).CONCLUSIONMR features of PanNENs vary according to their grade of differentiation and their stage at diagnosis and could predict the biological behavior of these tumors.
基金supported by the National Science Fundfor Distinguished Young Scholars (No. 50425825)the National Natural Science Foundation of China (No.50538080)
文摘The equivalence between multilayered barriers regarding diffusion and adsorption was studied. The bottom boundary of the liner system is defined by assuming concentration continuous and flux continuous conditions of the contaminant between the bottom liner layer and the underlying soil. Five different liner systems were compared in terms of solute breakthrough time. The results of the analysis showed that breakthrough time of the hydrophobic organic compounds for a 2-meter-thick compacted clay liner (CCL) could be 3-4 orders of magnitude is greater than the breakthrough time for a geosynthetic clay liner (GCL) composite liner. The GM/GCL and GM/CCL composite liner systems provide a better diffusion barrier for the hydrophilic organic compounds than that for the hydrophobic compounds due to their different Henry's coefficient. The calculated breakthrough times of the organic contaminants for the Chinese standard liner systems were found to be generally greater than those for the GCL alternatives, for the specific conditions examined. If the distribution coefficient increases to 2.8 for the hydrophobic compounds or 1.0 for the hydrophilic compounds, the thickness of the attenuation layer needed to achieve the same breakthrough time as the standard liner systems can be reduced by a factor of about 1.9-2.4. As far as diffusive and adsorption contaminant transport are concerned, GM or GCL is less effective than CCL.