Dynamic Calibration of the Cutting Temperature Sensor of NiCr/NiSi Thin-film Thermocouple 被引量:16
1
作者 CUI Yunxian YANG Deshun +2 位作者 JIA Ying ZENG Qiyong SUN Baoyuan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第1期73-77,共5页
In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring... In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring transient temperature accurately of cutting area on account of low response speed and limited cutting condition. In this paper, NiCr/NiSi thin-film thermocouples(TFTCs) are fabricated according to temperature characteristic of cutting area in high-speed cutting by means of advanced twinned microwave electro cyclotron resonance(MW-ECR) plasma source enhanced radio frequency(RF) reaction non-balance magnetron sputtering technique, and can be used for transient cutting temperature measurement. The time constants of the TFTCs with different thermo-junction film width are measured at four kinds of sampling frequency by using Ultra-CFR short pulsed laser system that established. One-dimensional unsteady heat conduction model is constructed and the dynamic performance is analyzed theoretically. It can be seen from the analysis results that the NiCr/NiSi TFTCs are suitable for measuring transient temperature which varies quickly, the response speed of TFTCs can be obviously improved by reducing the thickness of thin-film, and the area of thermo-junction has little influence on dynamic response time. The dynamic calibration experiments are made on the constructed dynamic calibration system, and the experimental results confirm that sampling frequency should be larger than 50 kHz in dynamic measurement for stable response time, and the shortest response time is 0.042 ms. Measurement methods and devices of cutting heat and cutting temperature measurement are developed and improved by this research, which provide practical methods and instruments in monitoring cutting heat and cutting temperature for research and production in high-speed machining. 展开更多
关键词 thin-film thermocouple cutting temperature sensor dynamic calibration one-dimensional unsteady heat conduction response time
下载PDF
在机床上安装“双显装置”的设计
2
作者 陈剑飞 许晓桢 《中原工学院学报》 CAS 1991年第2期22-31,共10页
本文提出了在专用机床上安装“双显装置”,即数字显示切削力和切削温度装置的设计方法。操作者观察“显示表”使切削加工在允许的切削力和温度范围内进行,有利于产品的质量和生产率的提高。同时,通过微机,单片机的处理系统和专用机床连... 本文提出了在专用机床上安装“双显装置”,即数字显示切削力和切削温度装置的设计方法。操作者观察“显示表”使切削加工在允许的切削力和温度范围内进行,有利于产品的质量和生产率的提高。同时,通过微机,单片机的处理系统和专用机床连机使用,工厂技术管理部门还可以在中央监测室随时通过微机显示和打印机打印出各专用机床加工时的切削力和切削温度数值,便于指挥生产。 展开更多
关键词 专用机床 数显装置 切削力 切削温度 传感器